Combining eco-sustainability and technological efficiency is one of the “hot” topics in the current construction and architectural sectors. In this work, recycled tire rubber aggregates and acoustically effective fractal cavities were combined in the design, modeling, and experimental characterization of lightweight concrete hollow bricks. After analyzing the structural and acoustic behavior of the brick models by finite element analysis as a function of the type of constituent concrete material (reference and rubberized cement mixes) and hollow inner geometry (circular- and fractal-shaped hollow designs), compressive tests and sound-absorption measurements were experimentally performed to evaluate the real performance of the developed prototypes. Compared to the traditional circular hollow pattern, fractal cavities improve the mechanical strength of the brick, its structural efficiency (strength-to-weight ratio), and the medium–high frequency noise damping. The use of ground waste tire rubber as a total concrete aggregate represents an eco-friendlier solution than the ordinary cementitious mix design, providing, at the same time, enhanced lightweight properties, mechanical ductility, and better sound attenuation. The near-compliance of rubber-concrete blocks with standard requirements and the value-added properties have demonstrated a good potential for incorporating waste rubber as aggregate for non-structural applications.
1 January 2022 in Journal of Synchrotron Radiation
Virtual histology is increasingly utilized to reconstruct the cell mechanisms underlying dental morphology for fragile fossils when physical thin sections are not permitted. Yet, the comparability of data derived from virtual and physical thin sections is rarely tested. Here, the results from archaeological human deciduous incisor physical sections are compared with virtual ones obtained by phase-contrast synchrotron radiation computed microtomography (SRµCT) of intact specimens using a multi-scale approach. Moreover, virtual prenatal daily enamel secretion rates are compared with those calculated from physical thin sections of the same tooth class from the same archaeological skeletal series. Results showed overall good visibility of the enamel microstructures in the virtual sections which are comparable to that of physical ones. The highest spatial resolution SRµCT setting (effective pixel size = 0.9 µm) produced daily secretion rates that matched those calculated from physical sections. Rates obtained using the lowest spatial resolution setup (effective pixel size = 2.0 µm) were higher than those obtained from physical sections. The results demonstrate that virtual histology can be applied to the investigated samples to obtain reliable and quantitative measurements of prenatal daily enamel secretion rates.