Yunbo Guo

Yunbo Guo

Auto-generated profile, based on publicly available information

Yunbo Guo

Chinese Academy of Sciences, Suzhou Institute of Biomedical Engineering and Technology, Suzhou, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Medical Image Analysis
Verified
Journal Article
Open access
Sharib AliSharib Ali
Sharib Ali
MDMariia Dmitrieva
Mariia Dmitrieva
NGNoha Ghatwary
Noha Ghatwary
SBSophia Bano
Sophia Bano
GPGorkem Polat
Gorkem Polat
JRJens Rittscher
Jens Rittscher
The Endoscopy Computer Vision Challenge (EndoCV) is a crowd-sourcing initiative to address eminent problems in developing reliable computer aided detection and diagnosis endoscopy systems and suggest a pathway for clinical translation of technologies. Whilst endoscopy is a widely used diagnostic and treatment tool for hollow-organs, there are several core challenges often faced by endoscopists, mainly: 1) presence of multi-class artefacts that hinder their visual interpretation, and 2) difficulty in identifying subtle precancerous precursors and cancer abnormalities. Artefacts often affect the robustness of deep learning methods applied to the gastrointestinal tract organs as they can be confused with tissue of interest. EndoCV2020 challenges are designed to address research questions in these remits. In this paper, we present a summary of methods developed by the top 17 teams and provide an objective comparison of state-of-the-art methods and methods designed by the participants for two sub-challenges: i) artefact detection and segmentation (EAD2020), and ii) disease detection and segmentation (EDD2020). Multi-center, multi-organ, multi-class, and multi-modal clinical endoscopy datasets were compiled for both EAD2020 and EDD2020 sub-challenges. The out-of-sample generalization ability of detection algorithms was also evaluated. Whilst most teams focused on accuracy improvements, only a few methods hold credibility for clinical usability. The best performing teams provided solutions to tackle class imbalance, and variabilities in size, origin, modality and occurrences by exploring data augmentation, data fusion, and optimal class thresholding techniques.

9 April 2024 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
XLXinze Li
Xinze Li
PSPeng Song
Peng Song
TLTiantian Lv
Tiantian Lv
YJYang Jiao
Yang Jiao
YGYunbo Guo
Yunbo Guo
YCYaoyao Cui
Yaoyao Cui

25 May 2025 in Expert Systems with Applications
Verified
Journal Article
Closed access
BWBilin Wang
Bilin Wang
CLChangda Lei
Changda Lei
YGYunbo Guo
Yunbo Guo
KHKaicheng Hong
Kaicheng Hong
XKXiuji Kan
Xiuji Kan
RLRui Li
Rui Li

13 September 2025 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
LZLesong Zheng
Lesong Zheng
YGYunbo Guo
Yunbo Guo
YLYing Liang
Ying Liang
LWLirong Wang
Lirong Wang
SMSiyu Meng
Siyu Meng
YTYuguo Tang
Yuguo Tang

8 January 2025 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
LZLesong Zheng
Lesong Zheng
YGYunbo Guo
Yunbo Guo
YLYing Liang
Ying Liang
LWLirong Wang
Lirong Wang
SMSiyu Meng
Siyu Meng
YTYuguo Tang
Yuguo Tang
The imprudent use of antibiotics has led to increased bacterial resistance, posing a serious threat to public health. Traditional visual-based antibiotic susceptibility testing (AST) methods are time-consuming and labor-intensive. Deep-learning-based bacterial detection algorithms have significantly improved the efficiency and accuracy of AST. However, existing deep-learning-based bacterial detection algorithms ignore unique challenges of AST images, such as confluent clusters, complex backgrounds, and morphologically similar noise. To address these issues, we propose a novel bacterial detection framework named the triple-stage contrastive learning framework with across-growth-stage information (TrCL-AGS). Specifically, we design a novel across-growth-stage pretraining (AGSP) task to mine across-growth-stage information from the continuous images, providing a richer and more robust feature space for subsequent stages. Instance-level contrastive learning (ILCL) is constructed to extract invariant semantic features of bacteria at a particular growth stage and exclude features similar to bacteria but do not match the specific growth stages. Besides, discriminative features between objects and backgrounds are enhanced by the category-level contrastive learning (CLCL) stage. Extensive experiments on a real-world clinical bacterial AST dataset demonstrate that our method can achieve state-of-the-art performance compared with existing object detection methods. And our framework is compatible with most detectors.

24 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
CLChangda Lei
Changda Lei
LCLing Chen
Ling Chen
SXShaoxian Xu
Shaoxian Xu
TGTao Guo
Tao Guo
XKXiuji Kan
Xiuji Kan
RLRui Li
Rui Li
Background: Large language models (LLMs) show promise in medical information support, but their efficacy in early gastric cancer (EGC) remains under-evaluated. This study systematically assesses LLMs performance in answering EGC clinical questions and analyzing white light endoscopy (WLE) and narrow band imaging (NBI) images.Methods: This study systematically reviewed clinical guidelines and interviewed patients to compile 40 clinical questions and 50 Single-choice questions related to EGC. Ten clinicians and ten EGC patients quantitatively scored LLM-generated responses across four dimensions: accuracy, correlation, completeness, and Comprehension. Readability metrics and Single-choice answer accuracy rates were further calculated. Additionally, the study incorporated 482 white light endoscopy (WLE) and 478 narrow band imaging (NBI) images from four hospitals in China. It systematically evaluated the diagnostic efficacy of different LLMs for multi-task recognition of EGC based on accuracy, sensitivity, specificity, and area under the curve (AUC).Findings: In text assessment, ChatGPT-4o achieved the highest scores for accuracy (86), correction (88), and comprehension (88), while Grok-3 scored highest for completeness (90). The accuracy rates for ChatGPT-4o, DeepSeek-V3.2, Gemini-2.5, and Grok-3 in answering Single-choice questions were 78%, 88%, 76%, and 82%, respectively. In image assessment, ChatGPT-5.2 demonstrated an accuracy of 62.33% (95% CI, 56.58–67.84), sensitivity of 86.77% (95% CI, 81.10–91.25), specificity of 0.57 (95% CI, 0.48–0.66), and an AUC of 20.72% (95% CI, 13.61–29.45) for identifying EGC in WLE images. 20.72% (95% CI, 13.61–29.45), 0.57 (95% CI, 0.48–0.66), respectively. For NBI images, the accuracy, sensitivity, specificity, and AUC were 58.00% (95% CI, 52.19–63.65), 88.41% (95% CI, 82.50-92.88), 21.32% (95% CI, 14.77-29.17), 0.50 (95% CI, 0.41-0.59). Gemini-3.0 pro demonstrated an accuracy of 83.67% (95% CI, 78.99–87.67),, 83.95% (95% CI, 83.84–84.05), 0, 0.50 (95% CI, 0.41–0.59), respectively. On NBI images, the accuracy, sensitivity, specificity, and AUC were 58.00% (95% CI, 52.19–63.65), 88.41% (95% CI, 82.50-92.88), 21.32% (95% CI, 14.77-29.17), 0.50 (95% CI, 0.41-0.59). Grok-4 demonstrated accuracy, sensitivity, specificity, and AUC values of 73.33% (95% CI, 67.95–78.25), 85.83% (95% CI, 80.77–89.99), 23.33% (95% CI, 13.38-36.04), 0.56 (95% CI, 0.46-0.65). On NBI images, the accuracy, sensitivity, specificity, and AUC were 78.33% (95% CI, 73.24-82.86), 83.27% (95% CI, 78.39-87.44), 5.26% (95% CI, 0.13-26.03), and 0.48 (95% CI, 0.39-0.56), respectively.Interpretation: LLMs has shown potential in addressing clinical issues related to EGC, but exhibits significant heterogeneity in text evaluation. In addition, the ability of LLMs to diagnose EGC in multimodal endoscopic images is still limited. Future efforts should focus on optimizing the structure of medical knowledge, enhancing multimodal understanding, and promoting clinical translation.