5 July 2021 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
We present the Core Imaging Library (CIL), an open-source Python framework for tomographic imaging with particular emphasis on reconstruction of challenging datasets. Conventional filtered back-projection reconstruction tends to be insufficient for highly noisy, incomplete, non-standard or multi-channel data arising for example in dynamic, spectral and in situ tomography. CIL provides an extensive modular optimization framework for prototyping reconstruction methods including sparsity and total variation regularization, as well as tools for loading, preprocessing and visualizing tomographic data. The capabilities of CIL are demonstrated on a synchrotron example dataset and three challenging cases spanning golden-ratio neutron tomography, cone-beam X-ray laminography and positron emission tomography. This article is part of the theme issue ‘Synergistic tomographic image reconstruction: part 2’.
5 July 2021 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
The newly developed core imaging library (CIL) is a flexible plug and play library for tomographic imaging with a specific focus on iterative reconstruction. CIL provides building blocks for tailored regularized reconstruction algorithms and explicitly supports multichannel tomographic data. In the first part of this two-part publication, we introduced the fundamentals of CIL. This paper focuses on applications of CIL for multichannel data, e.g. dynamic and spectral. We formalize different optimization problems for colour processing, dynamic and hyperspectral tomography and demonstrate CIL’s capabilities for designing state-of-the-art reconstruction methods through case studies and code snapshots. This article is part of the theme issue ‘Synergistic tomographic image reconstruction: part 2’.
11 June 2021 in Measurement Science and Technology
Long synonymous with medical imaging, x-ray computed tomography (CT) is proving its worth in industrial applications such as material characterization, defect analysis, and dimensional inspection e.g. of manufactured components. Since 2005, when the first purpose-built industrial x-ray CT instrument was made commercially available, there have been significant efforts to understand just how reliable x-ray CT dimensional measurements are. In metrology, the ultimate measure of confidence is metrological traceability—a clearly-defined but often not well-understood property of a measurement result. Metrological traceability places measurements on a comparable scale and provides a quantitative indication of measurement quality in the form of an uncertainty statement. From a practical perspective, achieving traceability can be divided into two tasks: (a) ensuring traceability of the scale with which the measurements are made and (b) assessing uncertainty in the resulting quantity assigned to the measurand. Based on this breakdown of the traceability problem, we provide a high-level discussion about traceability of x-ray CT dimensional measurements, review relevant work in understanding x-ray CT measurement uncertainty, and propose a framework for model-based uncertainty assessment per the Monte Carlo Simulation method and instrument scale calibration as a unified approach to traceability.
19 April 2018 in Measurement Science and Technology
The recent emergence of advanced manufacturing techniques such as additive manufacturing and an increased demand on the integrity of components have motivated research on the application of x-ray computed tomography (CT) for dimensional quality control. While CT has shown significant empirical potential for this purpose, there is a need for metrological research to accelerate the acceptance of CT as a measuring instrument. The accuracy in CT-based measurements is vulnerable to the instrument geometrical configuration during data acquisition, namely the relative position and orientation of x-ray source, rotation stage, and detector. Consistency between the actual instrument geometry and the corresponding parameters used in the reconstruction algorithm is critical. Currently available procedures provide users with only estimates of geometrical parameters. Quantification and propagation of uncertainty in the measured geometrical parameters must be considered to provide a complete uncertainty analysis and to establish confidence intervals for CT dimensional measurements. In this paper, we propose a computationally inexpensive model to approximate the influence of errors in CT geometrical parameters on dimensional measurement results. We use surface points extracted from a computer-aided design (CAD) model to model discrepancies in the radiographic image coordinates assigned to the projected edges between an aligned system and a system with misalignments. The efficacy of the proposed method was confirmed on simulated and experimental data in the presence of various geometrical uncertainty contributors.
8 June 2021 in Journal of Physics D: Applied Physics
Time-of-flight (ToF) neutron imaging offers complementary attenuation contrast to x-ray computed tomography, coupled with the ability to extract additional information from the variation in attenuation as a function of neutron energy (ToF) at every point (voxel) in the image. In particular, Bragg edge positions provide crystallographic information and therefore enable the identification of crystalline phases directly. Here we demonstrate Bragg edge tomography with high spatial and spectral resolution. We propose a new iterative tomographic reconstruction method with a tailored regularisation term to achieve high quality reconstruction from low-count data, where conventional filtered back-projection (FBP) fails. The regularisation acts in a separated mode for spatial and spectral dimensions and favours characteristic piece-wise constant and piece-wise smooth behaviour in the respective dimensions. The proposed method is compared against FBP and a state-of-the-art regulariser for multi-channel tomography on a multi-material phantom. The proposed new regulariser which accommodates specific image properties outperforms both conventional and state-of-the-art methods and therefore facilitates Bragg edge fitting at the voxel level. The proposed method requires significantly shorter exposures to retrieve features of interest. This in turn facilitates more efficient usage of expensive neutron beamline time and enables the full utilisation of state-of-the-art high resolution detectors.
6 March 2023 in Applied Mathematics in Science and Engineering
Spectral computed tomography has received considerable interest in recent years since spectral measurements contain much richer information about the object of interest. In spectral computed tomography, we are interested in the energy channel-wise reconstructions of the object. However, such reconstructions suffer from a low signal-to-noise ratio and share the challenges of conventional low-dose computed tomography such as ring artifacts. Ring artifacts arise from errors in the flat fields and can significantly degrade the quality of the reconstruction. We propose an extended flat-field model that exploits high correlation in the spectral flat fields to reduce ring artifacts in channel-wise reconstructions. The extended model relies on the assumption that the spectral flat fields can be well-approximated by a low-rank matrix. Our proposed model works directly on the spectral flat fields and can be combined with any existing reconstruction model, e.g. filtered back projection and iterative methods. The proposed model is validated on a neutron data set. The results show that our method successfully diminishes ring artifacts and improves the quality of the reconstructions. Moreover, the results indicate that our method is robust; it only needs a single spectral flat-field image, whereas existing methods need multiple spectral flat-field images to reach a similar level of ring reduction.