24 February 2025 in Biomechanics and Modeling in Mechanobiology
Accurate modeling of cardiovascular tissues is crucial for understanding and predicting their behavior in various physiological and pathological conditions. In this study, we specifically focus on the pulmonary artery in the context of the Ross procedure, using neural networks to discover the most suitable material model. The Ross procedure is a complex cardiac surgery where the patient’s own pulmonary valve is used to replace the diseased aortic valve. Ensuring the successful long-term outcomes of this intervention requires a detailed understanding of the mechanical properties of pulmonary tissue. Constitutive artificial neural networks offer a novel approach to capture such complex stress–strain relationships. Here, we design and train different constitutive neural networks to characterize the hyperelastic, anisotropic behavior of the main pulmonary artery. Informed by experimental biaxial testing data under various axial-circumferential loading ratios, these networks autonomously discover the inherent material behavior, without the limitations of predefined mathematical models. We regularize the model discovery using cross-sample feature selection and explore its sensitivity to the collagen fiber distribution. Strikingly, we uniformly discover an isotropic exponential first-invariant term and an anisotropic quadratic fifth-invariant term. We show that constitutive models with both these terms can reliably predict arterial responses under diverse loading conditions. Our results provide crucial improvements in experimental data agreement, and enhance our understanding into the biomechanical properties of pulmonary tissue. The model outcomes can be used in a variety of computational frameworks of autograft adaptation, ultimately improving the surgical outcomes after the Ross procedure.
15 July 2025 in Acta Biomaterialia
Fungi-based meat is emerging as a promising class of nutritious, sustainable, and minimally processed biomaterials with the potential to complement or replace traditional animal and plant-based meats. However, its mechanical and sensory properties remain largely unknown. Here we characterize the quasi-static and dynamic mechanical behavior of fungi-based steak using multi-axial mechanical testing, rheology, and texture profile analysis. We find that the rate-independent response under quasi-static compression and shear is isotropic, while the rate-dependent response under dynamic compression is markedly anisotropic with stiffnesses and peak forces four times larger cross-plane than in-plane. Automated model discovery reveals that the exponential Demiray model best explains the rate-independent elastic response upon chewing in both directions. The rate-dependent directional stiffening can be linked, at least in part, to the high water content of mushroom root mycelium and to the restricted fluid flow at higher loading rates. Complementary sensory surveys reveal a strong correlation with mechanical metrics and suggest that we perceive the fungi-based steak as more moist, more viscous, and more fibrous than traditional animal- and plant-based meats. Taken together, our findings position fungi-based steak as an attractive, structurally equivalent, and sensorially compelling alternative protein source that is healthy for people and for the planet.
12 October 2023 in Journal of the Mechanical Behavior of Biomedical Materials
10 February 2023 in Biomechanics and Modeling in Mechanobiology
28 July 2025 in Computers in Biology and Medicine
11 December 2025 in Journal of Biomechanical Engineering
Understanding the physiological condition of the vascular system is critical to explain, treat, and manage vascular disease. Numerous experimental and computational studies characterize the mechanical behavior of arterial tissue under controlled laboratory conditions. However, translating this knowledge into physiologically realistic conditions remains challenging. Key difficulties include selecting suitable and relevant test methods, minimizing uncertainty, and ensuring robust model validation. Here, we present a novel integrative approach to translate laboratory experiments on arterial samples into clinically relevant pressure–diameter behavior. We perform controlled planar-biaxial tests on carotid arteries under three stretch ratios and generate axial and circumferential stress–stretch data to calibrate a fiber-reinforced soft tissue model. Using an analytical thick-walled cylindrical model, we predict subject-specific pressure–diameter behavior, informed by arterial prestretches from ring opening experiments. We systematically compare predictions against extension-inflation experiments on tubes from the same artery by applying controlled pairs of axial stretch and inner pressure, while recording outer diameter. We quantify prediction error in absolute and relative stretch regimes and evaluate the importance of the load-free reference dimensions. Results show how planar-biaxial tests probe different stretch regimes compared to extension-inflation deformations, leading to extrapolation of model predictions. We demonstrate how the constitutive material parameters can be fitted to different biomechanical loading conditions, and we assess the sensitivity of the simulations to axial stretch and circumferential prestretch. Only when those key model parameters are accurately captured and their uncertainty propagated, planar-biaxial stress–stretch data can reliably predict arterial pressure–diameter behavior.