1 January 2014 in Annals of Oncology
The process leading to a regulatory outcome is guided by factors both related and unrelated to the data package, defined in this analysis as ‘formal and informal factors’, respectively. The aim of this qualitative study was to analyse which formal and informal factors drive the decision-making process of the European Medicines Agency (EMA) and Food and Drug Administration (FDA) regulators with regard to anticancer drugs, using in-depth semi-structured interviews with regulators of the two agencies. In line with the theory and practice of qualitative research, no set sample size was defined a priori. Respondent enrolment continued until saturation and redundancy were reached. Data were collected through means of in-depth semi-structured interviews conducted either in a face-to-face setting or via Skype® with each regulator. The interviews were audio-recorded and verbatim transcribed. The analysis was manually carried out on the transcribed text. Data were independently coded and categorized by two researchers. Interpretation of the findings emerged through a process of triangulation between the two. Seven EMA and six FDA regulators, who had extensive experience with making decisions about anticancer medicines, were interviewed between April and June 2012. There is an open dialogue between the FDA and EMA, with the two moving closer and exchanging information, not opinions. Differences in decision-making between the agencies may be due to a different evaluation of end points. Different interaction modalities with industry and patients represent an additional source of divergence with a potential impact on decision-making. The key message of our respondents was that the agencies manage uncertainty in a different way: unlike the EMA, the FDA has a prevailing attitude to take risks in order to guarantee quicker access to new treatments. Although formal factors are the main drivers for regulatory decisions, the influence of informal factors plays an important role in the drug evaluation process.
27 February 2008 in Annals of Oncology
Background: The aim of this study is to assess the use of interim analyses in randomised controlled trials (RCTs) testing new anticancer drugs, focussing on oncological clinical trials stopped early for benefit. Materials and methods: All published clinical trials stopped early for benefit and published in the last 11 years, regarding anticancer drugs and containing an interim analysis, were assessed. Results: Twenty-five RCTs were analysed. The evaluation of efficacy was protocol planned through time-related primary end points, >40% of them overall survival. In 95% of studies, at the interim analysis, efficacy was evaluated using the same end point as planned for the final analysis. As a consequence of early stopping after the interim analysis, ∼3300 patients/events across all studies were spared. More than 78% of the RCTs published in the last 3 years were used for registration purposes. Conclusion: Though criticism of the poor quality of oncological trials seems out of place, unfortunately early termination raises new concerns. The relation between sparing patients and saving time and trial costs indicates that there is a market-driven intent. We believe that only untruncated trials can provide a full level of evidence which can be translated into clinical practice without further confirmative trials.
25 January 2018 in British Journal of Clinical Pharmacology
Aims: The parallel regulatory–health technology assessment scientific advice (PSA) procedure allows manufacturers to receive simultaneous feedback from both EU regulators and health technology assessment (HTA) bodies on development plans for new medicines. The primary objective of the present study is to investigate whether PSA is integrated in the clinical development programmes for which advice was sought.Methods: Contents of PSA provided by regulators and HTA bodies for each procedure between 2010 and 2015 were analysed. The development of all clinical studies for which PSA had been sought was tracked using three different databases. The rate of uptake of the advice provided by regulators and HTA bodies was assessed on two key variables: comparator/s and primary endpoint.Results: In terms of uptake of comparator recommendations at the time of PSA in the actual development, our analysis showed that manufacturers implemented comparators to address both the needs of regulators and of at least one HTA body in 12 of 21 studies. For primary endpoints, in all included studies manufacturers addressed both the needs of the regulators and at least one HTA body.Conclusions: One of the key findings of this analysis is that manufacturers tend to implement changes to the development programme based on both regulatory and HTA advice with regards to the choice of primary endpoint and comparator. It also confirms the challenging choice of the study comparator, for which manufacturers seem to be more inclined to satisfy the regulatory advice. Continuous research efforts in this area are of paramount importance from a public health perspective.
21 November 2019 in British Journal of Clinical Pharmacology
15 August 2012 in British Journal of Clinical Pharmacology
Click on the article title to read more.
22 November 2017 in British Journal of Clinical Pharmacology
Background and aims: Biosimilars have been available in the European Union (EU) since 2006. However, their uptake in routine care is heterogeneous across countries. The aim of the present study was to compare the safety information of biosimilars and their originators based on the information in the European risk management plan (RMP).Methods: A cross‐sectional analysis on publicly available regulatory documents (RMPs and Summaries of Product Characteristics) of biosimilars and corresponding originators up to 1 November 2015 was performed. The safety concerns were extracted and merged into general safety concerns, and clinical relevance was assessed. The frequency of safety concerns and the representation of these safety concerns per general safety concern were assessed by either comparing RMPs of biosimilars and originators (if available for both) or comparing RMPs with the Summary of Product Characteristics of the originator.Results: Nineteen biosimilars and six originators were included. Overall, 55 general safety concerns (12 low, 21 medium and 22 highly clinically relevant) were identified. For all active substances, except for infliximab, no or only one difference was found in the listed general safety concerns. Comparison of regulatory documents for infliximab identified three medium clinically relevant general safety concerns more for infliximab biosimilars and two general safety concerns more for its originator.Conclusion: Based on publicly available information filed for regulatory purposes, no substantial differences were observed in the reporting of safety information for biosimilars and related originators. A direct comparison between biosimilars and related originators through formal postmarketing studies is needed to evaluate specific safety issues emerging during the products’ life cycle.