23 April 2018 in IEEE Transactions on Smart Grid
Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources' frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sources in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Simulation and field tests from Consortium for Electric Reliability Technology Solutions/American Electric Power microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter and generator mixed microgrids.
9 July 2018 in IEEE Transactions on Industry Applications
KSKarthikeyan Subramaniam
A synchronous generator-based distributed energy resource (DER) is commonly employed in microgrids due to its low cost and simple controls. However, there are many challenges to the DER operation when it is sized for supplying the critical loads alone in a microgrid. In particular, the DER would experience an overload condition during the microgrid transition from grid-connection to islanded operation, when the noncritical loads are also supplied momentarily. Therefore, it is very important to have a clear understanding on the survivability of a synchronous generator-based DER for transient overload conditions. Recently, experimental tests on survivability of the DER were carried out in the Consortium for Electric Reliability Technology Solutions Microgrid Testbed at American Electric Power. In this paper, an in-depth analysis of the synchronous generator-based DER operation during transient overload conditions is presented. The key relationships governing the system dynamic behavior of synchronous generator-based DER are analyzed to design the load shedding scheme for its survivability. Several case studies are illustrated to demonstrate the validity of the proposed load shedding method.
4 February 2020 in IEEE Transactions on Industry Applications
Station batteries used as a backup source to supply station direct-current (DC) power to relays, etc., present a source of personnel exposure to DC arc flash. DC arc flash is less understood compared with the arc flash phenomena that occur in alternating-current (AC) systems. Some models exist to quantify the potential hazards posed by DC electrical systems; however, there is little empirical data available. Additionally, the lower-voltage and/or lower-capacity station batteries are even less researched. As a result, a series of arc flash tests was performed at Dolan Technology Center of American Electric Power (AEP) utilizing two 125 Vdc batteries with rated capacities of 100 Ah and 150 Ah. For these tests, working distance and gap width were used as independent variables. Upon the conclusion of testing, various relationships were analyzed to generate a predictive model for incident energy. This model serves as a compilation of the empirical data collected during testing and will contribute to future research efforts to better understand DC arc flash incidents from station batteries.
5 December 2018 in IEEE Transactions on Industry Applications