Amrit S. Khalsa

Amrit S. Khalsa

Auto-generated profile, based on publicly available information

Amrit S. Khalsa

American Electric Power, Groveport, OH, USA

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2011 in Obesity
Verified
Journal Article
Open access
PDF file
CBCharles F. Bellows
Charles F. Bellows
YZYan Zhang
Yan Zhang
PSPaul J. Simmons
Paul J. Simmons
AKAmrit S. Khalsa
Amrit S. Khalsa
MKMikhail Kolonin
Mikhail Kolonin
Obesity complicates a number of diseases through mechanisms that are poorly defined. Mobilization and recruitment of progenitor cells to pathological sites is an important factor in disease progression. Here, we analyzed the influence of obesity on the systemic circulation of CD34+ cell populations and correlated frequencies of cells displaying previously established cell marker signatures with the BMI. Comparative analysis of peripheral blood mononuclear cells (PBMC) from 12 nonobese (BMI 30 kg/m2) disease‐free donors by flow cytometry revealed that obesity is associated with a fivefold increased frequency of circulating progenitor cells (CPC), a population consisting of hematopoietic and endothelial precursors. Our data also indicate that obesity is associated with increased frequency of circulating mesenchymal stromal progenitor cells (MSC). In contrast, the frequencies of mature endothelial cells (EC) and CD34‐bright leukocytes are unaffected by obesity. Combined, our results indicate that obesity promotes mobilization of progenitor cells, which may have clinical relevance.

23 April 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
WDWei Du
Wei Du
RLRobert H. Lasseter
Robert H. Lasseter
AKAmrit S. Khalsa
Amrit S. Khalsa
Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources' frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sources in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Simulation and field tests from Consortium for Electric Reliability Technology Solutions/American Electric Power microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter and generator mixed microgrids.

1 May 2020 in Spine
Verified
Journal Article
Closed access
AJAndre M. Jakoi
Andre M. Jakoi
GKGregory J. Kirchner
Gregory J. Kirchner
YKYehuda E. Kerbel
Yehuda E. Kerbel
JIJustin A. Iorio
Justin A. Iorio
AKAmrit S. Khalsa
Amrit S. Khalsa
Mini: This study compared clinical and patient-reported outcomes following transforaminal lumbar interbody fusion between patients who use or do not use marijuana. We found that patients who use marijuana are younger, but do not demonstrate any differences in preoperative or postoperative Oswestry disability index scores or rates of fusion. Study Design.: A retrospective cohort study. Objective.: The purpose of this study was to evaluate marijuana usage and its effect on outcomes following transforaminal lumbar interbody fusion (TLIF). Summary of Background Data.: As marijuana becomes legalized throughout the United States, its medicinal and recreational usage is becoming more mainstream. Clinicians currently have little guidance regarding both short-term and long-term effects of marijuana usage on surgical interventions. While the rate of lumbar spinal fusion in the United States continues to grow, the effect of marijuana usage on fusion remains uncertain. Methods.: One hundred two patients who underwent TLIF performed by the same surgeon were followed for 12 months. Patients were self-reported for marijuana usage (n = 36). Patient reported outcome measures included preoperative Oswestry disability index (ODI), 6-month ODI, and 12-month ODI, as well as length of stay (LOS), complications, return to operating room (OR), revision surgery, and confirmed fusion. Continuous variables were compared using the independent two-sample t test or analysis of variance (ANOVA), whereas categorical variables were analyzed using the chi-square or Fischer exact tests. Adjusted analysis was performed using a multivariate logistic regression model. Results.: Marijuana usage was associated with a younger population (P < 0.001), but showed no difference regarding sex or body mass index compared with the non-usage group. There was no statistically significant difference in complications, return to OR, or revision surgery between groups. When controlling for factors such as age and preoperative ODI, multivariate analysis demonstrated that marijuana usage did not limit postoperative ODI reduction. The marijuana usage group demonstrated shorter LOS (2.42 vs. 3.00 d, P = 0.020). Fusion rates at 12 months were similar between groups (96% vs. 92.3%, P = 0.678). ODI was similar between groups at all time points. Conclusion.: Perioperative outcomes were similar in patients who underwent TLIF regardless of marijuana usage. Level of Evidence: 3

9 July 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JCJongchan Choi
Jongchan Choi
AKAmrit Khalsa
Amrit Khalsa
DKDavid A. Klapp
David A. Klapp
MIMahesh Illindala
Mahesh Illindala
KSKarthikeyan Subramaniam
Karthikeyan Subramaniam
A synchronous generator-based distributed energy resource (DER) is commonly employed in microgrids due to its low cost and simple controls. However, there are many challenges to the DER operation when it is sized for supplying the critical loads alone in a microgrid. In particular, the DER would experience an overload condition during the microgrid transition from grid-connection to islanded operation, when the noncritical loads are also supplied momentarily. Therefore, it is very important to have a clear understanding on the survivability of a synchronous generator-based DER for transient overload conditions. Recently, experimental tests on survivability of the DER were carried out in the Consortium for Electric Reliability Technology Solutions Microgrid Testbed at American Electric Power. In this paper, an in-depth analysis of the synchronous generator-based DER operation during transient overload conditions is presented. The key relationships governing the system dynamic behavior of synchronous generator-based DER are analyzed to design the load shedding scheme for its survivability. Several case studies are illustrated to demonstrate the validity of the proposed load shedding method.

4 February 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
AGAustin C. Gaunce
Austin C. Gaunce
XWXuan Wu
Xuan Wu
JMJohn D. Mandeville
John D. Mandeville
DHDennis J. Hoffman
Dennis J. Hoffman
AKAmrit S. Khalsa
Amrit S. Khalsa
RWRonald J. Wellman
Ronald J. Wellman
Station batteries used as a backup source to supply station direct-current (DC) power to relays, etc., present a source of personnel exposure to DC arc flash. DC arc flash is less understood compared with the arc flash phenomena that occur in alternating-current (AC) systems. Some models exist to quantify the potential hazards posed by DC electrical systems; however, there is little empirical data available. Additionally, the lower-voltage and/or lower-capacity station batteries are even less researched. As a result, a series of arc flash tests was performed at Dolan Technology Center of American Electric Power (AEP) utilizing two 125 Vdc batteries with rated capacities of 100 Ah and 150 Ah. For these tests, working distance and gap width were used as independent variables. Upon the conclusion of testing, various relationships were analyzed to generate a predictive model for incident energy. This model serves as a compilation of the empirical data collected during testing and will contribute to future research efforts to better understand DC arc flash incidents from station batteries.