Vezir Rexhepi

Vezir Rexhepi

Auto-generated profile, based on publicly available information

Vezir Rexhepi

Technical University of Sofia

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Energy Procedia
Verified
Journal Article
Open access
VRVezir Rexhepi
Vezir Rexhepi

30 June 2020 in Journal of Energy Systems
Verified
Journal Article
Open access
PDF file
VRVezir Rexhepi̇
Vezir Rexhepi̇
AHAstrit Hulaj
Astrit Hulaj
Nowadays the advancement of technology and equipment to monitor the operating performance of power transformer has achieved a high level. So, the monitoring system enables the continued investigation of the operational work of power transformer parameters as well as the prevention of failures and enhance reliability. However, the monitoring of power transformers is of unquestionable value for the electrical power systems and consumers to have more reliability in supplying. Therefore, given that monitoring involves a considerable number of parameters and elements of transformers, in the present case the overview of the monitoring of some of the most important parameters has been taken into account. Thus, the paper includes the monitoring parameters such as; partial discharges, oil and winding temperatures, bushing currents, tap changer, moisture and dissolved gas analysis. Also, in the paper are presented data for the operation of these parameters in different periods as well as with different loading regimes. The reports of events that correspond to the operational performance of the transformer, which are a good cause for diagnosis and preliminary actions in transformers, are also presented.

31 July 2018 in Journal of Mechatronics, Electrical Power, and Vehicular Technology
Verified
Journal Article
Open access
PDF file
VRVezir Rexhepi
Vezir Rexhepi
PNPetar Nakov
Petar Nakov
Power transformers are one of the most expensive components; therefore the focus on their status and its continuous operation is the primary task. In the power systems, condition assessment of performance and reliability is based on the state of components, measurements, testing and maintenance as well as their diagnosis. Hence, condition assessment of power transformer parameters is the most important regarding their status and finding incipient failures. Among many factors, the most factors that affects the safe operation and life expentancy of the transformer is the moisture in oil. It is known that the low moisture oil in power transformers causes many problems including electrical breakdown, increase the amount of partial discharge, decreases the dielectric withstand strength and other phenomena. Thus, knowledge about the moisture concentration in a power transformer is significantly important for safe operation and lifespan. In this study, moisture level in oil is estimated and its status classification is proposed by using fuzzy logic techniques for the power transformer monitoring and condition assessment. Moreover, the goal of the study is to find methods and techniques for the condition assessment of power transformers status based on the state of moisture in oil using the fuzzy logic technique. These applied techniques increase the power system reliability, help to reduce incipient failures, and give the better maintenance plan using an algorithm based on logic rules. Also, by using the fuzzy logic techniques, it is easier to prevent failures which may have consequences not only for transformers but also for the power system as a whole.

28 March 2025 in Corporate and Business Strategy Review
Verified
Journal Article
Open access
PDF file
SRShaqir Mehmet Rexhepi
Shaqir Mehmet Rexhepi
RSRexhep Shaqiri
Rexhep Shaqiri
RVRovena Vangjel
Rovena Vangjel
VRVezir Rexhepi
Vezir Rexhepi
GVGjelosh Gjon Vataj
Gjelosh Gjon Vataj
This paper evaluates the financial feasibility of the wind energy production project at the Kitka Substation (SS Kitka), focusing on its technical and economic aspects, return on capital investment, and broader environmental and social implications. The study’s findings indicate that for the period of January to June 2022, the project generated total revenues of €3,749,466.11, while operating expenses amounted to €1,780,000. With a total investment of €48,000,000, the capital return for this period was calculated at €1,969,466.11. The analysis of wind energy production data from January to August 2022 recorded a total output of 56,562.25 MWh. Moreover, the project contributed €10,160,047 in revenue to the Kosovo government through wind-generated energy from the SS Kitka facility. Based on financial projections, the annual return on investment (ROI) for the capital invested is estimated at €3,938,932.22. Consequently, the full recovery of the initial €48 million investment is projected to be achieved within 12 years. These findings underscore the long-term financial viability of the SS Kitka wind energy project, reinforcing its role in promoting sustainable energy development and economic growth.

1 March 2024 in Ecological Engineering & Environmental Technology
Verified
Journal Article
Open access
SRShaqir Mehmet Rexhepi
Shaqir Mehmet Rexhepi
VRVezir Rexhepi
Vezir Rexhepi
The operation of modern power systems requires a sophisticated technological infrastructure to effectively manage and evaluate their parameters and performance. This infrastructure includes the generation, transmission and distribution power system components. This paper provides an overview of...

1 May 2016 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
VRVezir Rexhepi
Vezir Rexhepi
Harmonic analysis studies have become an important component of power system analysis and design on recent years. They are used to quantify the distortion in voltage and current waveform and avoid them to propagate through the AC network. Harmonics are created mainly by nonlinear loads in power systems. Thus, in this paper are analyzed the harmonics created by industrial loads and other electronic devices and their effects.