Fangwei Wang

Fangwei Wang

Auto-generated profile, based on publicly available information

Fangwei Wang

Institute of Microelectronics and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2021 in ACS Nano
Verified
Journal Article
Closed access
JXJiandong Xu
Jiandong Xu
RLRuisong Li
Ruisong Li
SJShourui Ji
Shourui Ji
BZBingchen Zhao
Bingchen Zhao
TCTianrui Cui
Tianrui Cui
TRTian-Ling Ren
Tian-Ling Ren

6 February 2020 in ACS Nano
Verified
Journal Article
Closed access
XGXiangshun Geng
Xiangshun Geng
FWFangwei Wang
Fangwei Wang
He TianHe Tian
He Tian
QFQixin Feng
Qixin Feng
HZHainan Zhang
Hainan Zhang
TRTian-Ling Ren
Tian-Ling Ren

18 March 2020 in ACS Nano
Verified
Journal Article
Closed access
YQYancong Qiao
Yancong Qiao
GGGuangyang Gou
Guangyang Gou
FWFan Wu
Fan Wu
JJJinming Jian
Jinming Jian
XLXiaoshi Li
Xiaoshi Li
TRTian-Ling Ren
Tian-Ling Ren

22 October 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YQYancong Qiao
Yancong Qiao
XLXiaoshi Li
Xiaoshi Li
JJJinming Jian
Jinming Jian
QWQi Wu
Qi Wu
YWYuhong Wei
Yuhong Wei
TRTian-Ling Ren
Tian-Ling Ren

23 April 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FWFangwei Wang
Fangwei Wang
JJJinming Jian
Jinming Jian
XGXiangshun Geng
Xiangshun Geng
GGGuangyang Gou
Guangyang Gou
WCWenpu Cui
Wenpu Cui
TRTian-Ling Ren
Tian-Ling Ren
Humidity detection has significant and extensive applications in various fields. Herein, a miniaturized integrated relative humidity (RH) sensing system from surface acoustic wave (SAW) sensor to circuits and software is described. Delay-line SAW devices were designed and fabricated to be used as sensor and reference device. Graphene oxide (GO) was deposited on the surface of SAW sensor between interdigitated transducers (IDTs) as ultra-thin and wrinkled sensitive film by the method of dropcast. The well-matched circuits and software with excellent stability and accuracy were developed to form a miniaturized integrated relative humidity sensing system with SAW sensor. A linear variation of the frequency shift is obtained in an extremely wide detection range from 0 to 97.3 %RH. Besides, the system exhibits a high sensitivity of 3.33 kHz/%RH, rapid response time of 80 s and recovery time of 72 s, good dynamic response and excellent repeatability. These results demonstrate that the SAW sensing system not only realizes humidity detection at system level, but also has excellent performance, which shows great feasibility and tremendous potential for relative humidity measurement applications.