Hang Yin

Hang Yin

Auto-generated profile, based on publicly available information

Hang Yin

School of Electrical Engineering, Tel Aviv University, Ramat Aviv, Israel

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZKZeev Kustanovich
Zeev Kustanovich
SSShivprasad Shivratri
Shivprasad Shivratri
HYHang Yin
Hang Yin
FRFlorian Reissner
Florian Reissner
GWGeorge Weiss
George Weiss
Virtual synchronous machines (VSMs) are inverters that behave toward the power-grid-like synchronous generators. Hence, they can be used as grid-forming inverters, and they can support the grid with inertia, droops, fault ride-through, and more. Synchronverters are a much studied type of VSMs. In this article, we present several improvements and innovations to the synchronverter control algorithm. We offer a complete design procedure for this algorithm. One change is meant to mitigate the fact that earlier designs are very sensitive to grid voltage measurement errors and processing delay, which may cause harmonic distortion and fluctuating amplitude of the grid-side currents. We propose to include a fast current controller as the internal control loop of the inverter. The design of this current controller involves delicate issues of compensating the delays and eliminating the dc components of the currents. The new design also enables a natural way for distortionless current limitation. We present a smooth start-up procedure. Our simulations and experiments show that the current controller leads to a dramatic reduction of the sensitivity of the VSM to measurement errors, processing delay, and grid voltage imbalance

31 December 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
FRFlorian Reissner
Florian Reissner
HYHang Yin
Hang Yin
GWGeorge Weiss
George Weiss
We prove that virtual friction can stabilize a power grid containing several virtual synchronous machines (VSMs), connecting line impedances and loads. Virtual friction is a torque added to the swing equation of each VSM, proportional to the deviation of its frequency from the overall center of inertia (COI) frequency. Our analysis is based on the network reduced power system (NRPS) model. We support our results with simulations for a two-area network of four VSMs, looking at the transients induced by a change of tie-line impedance and an asymmetric load change. We compare the results for the NRPS model with the corresponding results using detailed models of synchronverters and line impedances. We find that virtual friction has a strong stabilizing effect both for the NRPS model and for the detailed model. Furthermore we show simulation results on the influence of time delays in the communication between the inverters. This communication is used to compute the COI frequency. It turns out that communication delays of less than 100ms have practically no effect on the overall system.

21 August 2024 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
HYHang Yin
Hang Yin
ZKZeev Kustanovich
Zeev Kustanovich
JLJyun Lin
Jyun Lin
GWGeorge Weiss
George Weiss
Synchronous generators (SG) have damper windings on their rotor that help to dampen the oscillations. Virtual synchronous machine (VSM) are inverters that emulate the behavior of SGs. Usually, these have no damper windings, instead they make use of fast frequency droop to help maintain the power balance in the grid and also for the damping of unwanted oscillations. The drawback is that the inverter is required to be able to inject or absorb extra power, depending on the grid frequency. We propose a simple model of a damper winding, that can be added to the control algorithm of a VSM. A precise model of the damper windings present in a SG is complicated and necessities several additional state variables. Instead, we propose a very simple but effective approximation, where the virtual damper winding (VDW) torque Tw is derived directly from the existing state variables of the VSM and its terminal voltages. There is no need for a phase-locked loop to estimate the grid frequency ωg, even though Tw depends on the difference between the internal frequency ω and ωg. The analysis is based on a simplified model of a synchronverter. The proposed algorithm has been verified both by simulations and microgrid experiments. The performance of the proposed algorithm has been compared to the performance of two other recently proposed algorithms which use a damping torque in addition to frequency droop, and which also do not rely on a PLL for this

6 November 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HYHang Yin
Hang Yin
SWShimin Wang
Shimin Wang
ZZZiqi Zhou
Ziqi Zhou
A virtual oscillator (VO) based frequency-locked loop (FLL) is proposed to estimate the grid frequency ω g and added to the control algorithm of a virtual synchronous machine (VSM) in order to better dampen oscillations in a power system comprising VSMs. The VO present in the virtual capacitor is used to estimate the ripple frequency. Similarly, A very simple but effective approximation is proposed, which features first-order dynamics instead of second-order in the conventional FLL. The change of VSM is to add a virtual oscillator to offer a local friction-damping torque. The effect of the damping torque on the rotor of a VSM is similar to the presence of local friction damping on the same axis. Assumed that the damping torque is proportional to the frequency difference of ω-ω g . Derive the damping torque Tvo based on the virtual oscillator from the existing state variables of the fourth-order VSM model and its terminal voltages. Simulations and experiments verify the effectiveness of the proposed method in power oscillations damping.

14 December 2021
Verified
Conference Paper
Open access
FRFlorian Reissner
Florian Reissner
HYHang Yin
Hang Yin
GWGeorge Weiss
George Weiss
We prove that virtual friction control can stabilize a power grid containing several virtual synchronous machines (VSMs), connecting line impedances and loads. Virtual friction is a torque added to the swing equation of each VSM, proportional to the deviation of its frequency from the overall center of inertia (COI) frequency. Our analysis is based on the network reduced power system (NRPS) model. We support our results with simulations for a two-area network of four VSMs, looking at the transients induced by a change of tie-line impedance and an asymmetric load change. We compare the results for the NRPS model with the corresponding results using detailed models of synchronverters and line impedances. We find that virtual friction has a strong stabilizing effect both for the NRPS model and for the full grid model.

2 June 2022 in TechRxiv
Verified
Preprint
Open access
PDF file
ZKZeev Kustanovich
Zeev Kustanovich
SSShivprasad Shivratri
Shivprasad Shivratri
HYHang Yin
Hang Yin
FRFlorian Reissner
Florian Reissner
GWGeorge Weiss
George Weiss
Virtual synchronous machines (VSM) are inverters that behave towards the power grid like synchronous generators. Hence, they can be used as grid forming inverters and they can support the grid with inertia, droops, fault ride-through and more. Synchronverters are a much studied type of VSM. In this paper we present several improvements and innovations to the synchronverter control algorithm. We offer a complete design procedure for this algorithm. One change is meant to mitigate the fact that earlier designs are very sensitive to grid voltage measurement errors and processing delay, which may cause harmonic distortion and fluctuating amplitude of the grid-side currents. We propose to include a fast current controller as the internal control loop of the inverter. The design of this current controller involves delicate issues of compensating the delays and eliminating the DC components of the currents. The new design enables also a natural way for distortion-less current limitation. We present a smooth start?up procedure. Our simulations and experiments show that the current controller leads to a dramatic reduction of the sensitivity of the VSM to measurement errors, processing delay and grid voltage imbalance.