Jakub Grepl

Jakub Grepl

Auto-generated profile, based on publicly available information

Jakub Grepl

Department of Oncology and Radiotherapy, University Hospital and Medical Faculty Hradec Kralove Hradec Kralove, Czech Republic

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GOGráinne O’bRien
Gráinne O’bRien
LCLourdes Cruz-Garcia
Lourdes Cruz-Garcia
MMMatthäus Majewski
Matthäus Majewski
JGJakub Grepl
Jakub Grepl
MAMichael Abend
Michael Abend
Christophe BadieChristophe Badie
Christophe Badie
Previous investigations in gene expression changes in blood after radiation exposure have highlighted its potential to provide biomarkers of exposure. Here, FDXR transcriptional changes in blood were investigated in humans undergoing a range of external radiation exposure procedures covering several orders of magnitude (cardiac fluoroscopy, diagnostic computed tomography (CT)) and treatments (total body and local radiotherapy). Moreover, a method was developed to assess the dose to the blood using physical exposure parameters. FDXR expression was significantly up-regulated 24 hr after radiotherapy in most patients and continuously during the fractionated treatment. Significance was reached even after diagnostic CT 2 hours post-exposure. We further showed that no significant differences in expression were found between ex vivo and in vivo samples from the same patients. Moreover, potential confounding factors such as gender, infection status and anti-oxidants only affect moderately FDXR transcription. Finally, we provided a first in vivo dose-response showing dose-dependency even for very low doses or partial body exposure showing good correlation between physically and biologically assessed doses. In conclusion, we report the remarkable responsiveness of FDXR to ionising radiation at the transcriptional level which, when measured in the right time window, provides accurate in vivo dose estimates.

23 February 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ATAles Tichy
Ales Tichy
SKSylwia Kabacik
Sylwia Kabacik
GOGrainne O'Brien
Grainne O'Brien
JPJaroslav Pejchal
Jaroslav Pejchal
ZSZuzana Sinkorova
Zuzana Sinkorova
Christophe BadieChristophe Badie
Christophe Badie
The increasing risk of acute large-scale radiological/nuclear exposures of population underlines the necessity of developing new, rapid and high throughput biodosimetric tools for estimation of received dose and initial triage. We aimed to compare the induction and persistence of different radiation exposure biomarkers in human peripheral blood in vivo. Blood samples of patients with indicated radiotherapy (RT) undergoing partial body irradiation (PBI) were obtained soon before the first treatment and then after 24 h, 48 h, and 5 weeks; i.e. after 1, 2, and 25 fractionated RT procedures. We collected circulating peripheral blood from ten patients with tumor of endometrium (1.8 Gy per fraction) and eight patients with tumor of head and neck (2.0–2.121 Gy per fraction). Incidence of dicentrics and micronuclei was monitored as well as determination of apoptosis and the transcription level of selected radiation-responsive genes. Since mitochondrial DNA (mtDNA) has been reported to be a potential indicator of radiation damage in vitro, we also assessed mtDNA content and deletions by novel multiplex quantitative PCR. Cytogenetic data confirmed linear dose-dependent increase in dicentrics (p < 0.01) and micronuclei (p < 0.001) in peripheral blood mononuclear cells after PBI. Significant up-regulations of five previously identified transcriptional biomarkers of radiation exposure (PHPT1, CCNG1, CDKN1A, GADD45, and SESN1) were also found (p < 0.01). No statistical change in mtDNA deletion levels was detected; however, our data indicate that the total mtDNA content decreased with increasing number of RT fractions. Interestingly, the number of micronuclei appears to correlate with late radiation toxicity (r2 = 0.9025) in endometrial patients suggesting the possibility of predicting the severity of RT-related toxicity by monitoring this parameter. Overall, these data represent, to our best knowledge, the first study providing a multiparametric comparison of radiation biomarkers in human blood in vivo, which have potential for improving biological dosimetry.

1 May 2020 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Closed access
MVMilan Vošmik
Milan Vošmik
MHMiroslav Hodek
Miroslav Hodek
DBDavid Buka
David Buka
PSPetra Sýkorová
Petra Sýkorová
JGJakub Grepl
Jakub Grepl
ISIgor Sirak
Igor Sirak
With a development of radiotherapeutic techniques, availability of radiotherapy data on cardiotoxicity, and slowly improving esophageal cancer outcomes, an increasing emphasis is placed on the heart protection in radiation treated esophageal cancer patients. Radiation induced heart complications encompass mainly pericardial disease, cardiomyopathy, coronary artery atherosclerosis, valvular heart disease, and arrhythmias. The most frequent toxicity is pericardial effusion which is usually asymptomatic in the majority of patients. The use of modern radiotherapy techniques is expected to reduce the risk of cardiotoxicity, although this expectation has to be confirmed by clinical data.

26 May 2022 in Cancers
Verified
Journal Article
Open access
PDF file
LCLourdes Cruz-Garcia
Lourdes Cruz-Garcia
FNFarah Nasser
Farah Nasser
GOGrainne O’brien
Grainne O’brien
JGJakub Grepl
Jakub Grepl
VVVolodymyr Vinnikov
Volodymyr Vinnikov
Christophe BadieChristophe Badie
Christophe Badie
External beam radiation therapy leads to cellular activation of the DNA damage response (DDR). DNA double-strand breaks (DSBs) activate the ATM/CHEK2/p53 pathway, inducing the transcription of stress genes. The dynamic nature of this transcriptional response has not been directly observed in vivo in humans. In this study we monitored the messenger RNA transcript abundances of nine DNA damage-responsive genes (CDKN1A, GADD45, CCNG1, FDXR, DDB2, MDM2, PHPT1, SESN1, and PUMA), eight of them regulated by p53 in circulating blood leukocytes at different time points (2, 6–8, 16–18, and 24 h) in cancer patients (lung, neck, brain, and pelvis) undergoing radiotherapy. We discovered that, although the calculated mean physical dose to the blood was very low (0.038–0.169 Gy), an upregulation of Ferredoxin reductase (FDXR) gene transcription was detectable 2 h after exposure and was dose dependent from the lowest irradiated percentage of the body (3.5% whole brain) to the highest, (up to 19.4%, pelvic zone) reaching a peak at 6–8 h. The radiation response of the other genes was not strong enough after such low doses to provide meaningful information. Following multiple fractions, the expression level increased further and was still significantly up-regulated by the end of the treatment. Moreover, we compared FDXR transcriptional responses to ionizing radiation (IR) in vivo with healthy donors’ blood cells exposed ex vivo and found a good correlation in the kinetics of expression from the 8-hours time-point onward, suggesting that a molecular transcriptional regulation mechanism yet to be identified is involved. To conclude, we provided the first in vivo human report of IR-induced gene transcription temporal response of a panel of p53-dependant genes. FDXR was demonstrated to be the most responsive gene, able to reliably inform on the low doses following partial body irradiation of the patients, and providing an expression pattern corresponding to the % of body exposed. An extended study would provide individual biological dosimetry information and may reveal inter-individual variability to predict radiotherapy-associated adverse health outcomes.

1 May 2012 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Closed access
PPPetr Paluska
Petr Paluska
JHJosef Hanus
Josef Hanus
JSJana Sefrova
Jana Sefrova
LRLucie Rouskova
Lucie Rouskova
JGJakub Grepl
Jakub Grepl
JPJiri Petera
Jiri Petera
To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

19 December 2022 in Cancers
Verified
Journal Article
Open access
PDF file
DPDenisa Pohanková
Denisa Pohanková
ISIgor Sirak
Igor Sirak
MVMilan Vošmik
Milan Vošmik
LKLinda Kašaová
Linda Kašaová
JGJakub Grepl
Jakub Grepl
Petera JiříPetera Jiří
Petera Jiří
Background: Low-dose-rate brachytherapy is an effective organ-sparing treatment for patients with early-stage penile cancer. However, only limited data are available on the role of high-dose-rate brachytherapy (HDR-BT) in this clinical setting. Methods: Between 2002 and 2020, 31 patients with early penile cancer were treated at our center with interstitial HDR BT at a dose of 18 × 3 Gy twice daily. A breast brachytherapy template was used for the fixation of stainless hollow needles. Results: The median follow-up was 117.5 months (range, 5–210). Eight patients (25.8%) developed a recurrence; of these, seven were salvaged by partial amputation. Six patients died of internal comorbidities or a second cancer. The probability of local control at 5 and 10 years was 80.7% (95% CI: 63.7–97.7%) and 68.3% (95% CI: 44.0–92.6%), respectively. Cause-specific survival was 100%. Only one case of radiation-induced necrosis was observed. The probability of penile sparing at 5 and 10 years was 80.6% (95% CI: 63.45–97.7%) and 62.1% (95% CI: 34.8–89.4%), respectively. Conclusions: These results show that HDR-BT for penile cancer can achieve results comparable to LDR-BT with organ sparing. Despite the relatively large patient cohort—the second largest reported to date in this clinical setting—prospective data from larger samples are needed to confirm the role of HDR-BT in penile cancer.