Bachir Ahmed Abeid

Bachir Ahmed Abeid

Auto-generated profile, based on publicly available information

Bachir Ahmed Abeid

Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2024 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
BABachir A. Abeid
Bachir A. Abeid
MFMario L. Fabiilli
Mario L. Fabiilli
JEJonathan B. Estrada
Jonathan B. Estrada
MAMitra Aliabouzar
Mitra Aliabouzar
Phase-shift droplets are a highly adaptable platform for biomedical applications of ultrasound. The spatiotemporal response of phase-shift droplets to focused ultrasound above a certain pressure threshold, termed acoustic droplet vaporization (ADV), is influenced by intrinsic features (e.g., bulk boiling point) and extrinsic factors (e.g., driving frequency and surrounding media). A deep understanding of ADV dynamics is critical to ensure the robustness and repeatability of an ADV-assisted application. Here, we integrated ultra-high-speed imaging, at 10 million frames per second, and confocal microscopy for a full-scale (i.e., from nanoseconds to seconds) characterization of ADV. Experiments were conducted in fibrin-based hydrogels to mimic soft tissue environments. Effects of fibrin concentration (0.2 to 8 % (w/v)), excitation frequency (1, 2.5, and 9.4 MHz), and perfluorocarbon core (perfluoropentane, perfluorohexane, and perfluorooctane) on ADV dynamics were studied. Several fundamental parameters related to ADV dynamics, such as expansion ratio, expansion velocity, collapse radius, collapse time, radius of secondary rebound, resting radius, and equilibrium radius of the generated bubbles were extracted from the radius vs time curves. Diffusion-driven ADV-bubble growth was fit to a modified Epstein-Plesset equation, adding a material stress term, to estimate the growth rate. Our results indicated that ADV dynamics were significantly impacted by fibrin concentration, frequency, and perfluorocarbon liquid core. This is the first study to combine ultra-high-speed and confocal microscopy techniques to provide insights into ADV bubble dynamics in tissue-mimicking hydrogels.

1 January 2025 in Bioactive Materials
Verified
Journal Article
Open access
Somnath MajiSomnath Maji
Somnath Maji
MAMitra Aliabouzar
Mitra Aliabouzar
CQCarole Quesada
Carole Quesada
ACAnjali Chiravuri
Anjali Chiravuri
AMAidan Macpherson
Aidan Macpherson
MFMario L. Fabiilli
Mario L. Fabiilli
Hydrogels can improve the delivery of mesenchymal stromal cells (MSCs) by providing crucial biophysical cues that mimic the extracellular matrix. The differentiation of MSCs is dependent on biophysical cues like stiffness and viscoelasticity, yet conventional hydrogels cannot be dynamically altered after fabrication and implantation to actively direct differentiation. We developed a composite hydrogel, consisting of type I collagen and phase-shift emulsion, where osteogenic differentiation of MSCs can be non-invasively modulated using ultrasound. When exposed to ultrasound, the emulsion within the hydrogel was non-thermally vaporized into bubbles, which locally compacted and stiffened the collagen matrix surrounding each bubble. Bubble growth and matrix compaction were correlated, with collagen regions proximal (i.e., ≤ ∼60 μm) to the bubble displaying a 2.5-fold increase in Young's modulus compared to distal regions (i.e., > ∼60 μm). The viability and proliferation of MSCs, which were encapsulated within the composite hydrogel, were not impacted by bubble formation. In vitro and in vivo studies revealed encapsulated MSCs exhibited significantly elevated levels of RUNX2 and osteocalcin, markers of osteogenic differentiation, in collagen regions proximal to the bubble compared to distal regions. Additionally, alkaline phosphatase activity and calcium deposition were enhanced adjacent to the bubble. An opposite trend was observed for CD90, a marker of MSC stemness. Following subcutaneous implantation, bubbles persisted in the hydrogels for two weeks, which led to localized collagen alignment and increases in nuclear asymmetry. These results are a significant step toward controlling the 3D differentiation of MSCs in a non-invasive and on-demand manner.

13 October 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
BABachir A. Abeid
Bachir A. Abeid
MFMario L. Fabiilli
Mario L. Fabiilli
MAMitra Aliabouzar
Mitra Aliabouzar
JEJonathan B. Estrada
Jonathan B. Estrada

30 July 2025 in Soft Matter
Verified
Journal Article
Open access
PDF file
ZZZhiren Zhu
Zhiren Zhu
SRSawyer Remillard
Sawyer Remillard
BABachir Ahmed Abeid
Bachir Ahmed Abeid
DFDanila Frolkin
Danila Frolkin
SBSpencer H. Bryngelson
Spencer H. Bryngelson
JEJon Estrada
Jon Estrada
The ultra-high-rate, finite viscoelastic properties of soft hydrogels and fluids are rapidly characterized according to the time to first collapse of laser-induced cavities.

11 September 2023 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
MAMitra Aliabouzar
Mitra Aliabouzar
BABachir A. Abeid
Bachir A. Abeid
OKOliver Kripfgans
Oliver Kripfgans
JFJ. Brian Fowlkes
J. Brian Fowlkes
JEJonathan B. Estrada
Jonathan B. Estrada
MFMario L. Fabiilli
Mario L. Fabiilli
Phase-shift droplets provide a flexible and dynamic platform for therapeutic and diagnostic applications of ultrasound. The spatiotemporal response of phase-shift droplets to focused ultrasound, via the mechanism termed acoustic droplet vaporization (ADV), can generate a range of bioeffects. Although ADV has been used widely in theranostic applications, ADV-induced bioeffects are understudied. Here, we integrated ultra-high-speed microscopy, confocal microscopy, and focused ultrasound for real-time visualization of ADV-induced mechanics and sonoporation in fibrin-based, tissue-mimicking hydrogels. Three monodispersed phase-shift droplets—containing perfluoropentane (PFP), perfluorohexane (PFH), or perfluorooctane (PFO)—with an average radius of ∼6 μm were studied. Fibroblasts and tracer particles, co-encapsulated within the hydrogel, were used to quantify sonoporation and mechanics resulting from ADV, respectively. The maximum radial expansion, expansion velocity, induced strain, and displacement of tracer particles were significantly higher in fibrin gels containing PFP droplets compared to PFH or PFO. Additionally, cell membrane permeabilization significantly depended on the distance between the droplet and cell (d), decreasing rapidly with increasing d. Significant membrane permeabilization occurred when d was smaller than the maximum radius of expansion. Both ultra-high-speed and confocal images indicate a hyper-local region of influence by an ADV bubble, which correlated inversely with the bulk boiling point of the phase-shift droplets. The findings provide insight into developing optimal approaches for therapeutic applications of ADV.

5 March 2025 in Langmuir
Verified
Journal Article
Closed access
SCSugandha Chaudhary
Sugandha Chaudhary
AKAnuj Kaushik
Anuj Kaushik
BABachir A. Abeid
Bachir A. Abeid
JEJonathan B. Estrada
Jonathan B. Estrada
MFMario L. Fabiilli
Mario L. Fabiilli
MAMitra Aliabouzar
Mitra Aliabouzar