22 December 2009 in IEEE Transactions on Power Systems
MFMahmud Fotuhi-Firuzabad
In this paper, a model for the optimal placement of contingency-constrained phasor measurement units (PMUs) in electric power networks is presented. The conventional complete observability of power networks is first formulated and then, different contingency conditions in power networks including measurement losses and line outages are added to the main model. The communication constraints which would limit the maximum number of measurements associated with each installed PMU is considered as measurement limitations. The relevant formulations are also proposed to make the model more comprehensive. The IEEE standard test systems are examined for the applicability of proposed model. The comparison of presented results with those of other methods is presented which would justify the effectiveness of proposed model with regards to minimizing the total number of PMUs and the execution time. A large-scale system with 2383 buses is also analyzed to exhibit the applicability of proposed model to practical power system cases.
10 August 2016 in IEEE Transactions on Smart Grid
In recent years, natural disasters around the world have underscored the need for operative solutions that can improve the power grid resilience in response to low-probability high-impact incidents. The advent of microgrids (MGs) in modern power systems has introduced promising measures that can fulfil the power network resiliency requirements. This paper presents a two-stage stochastic programming approach to the optimal scheduling of a resilient MG. The impact of natural disasters on the optimal operation of MGs is modeled using a stochastic programming process. Other prevailing uncertainties associated with wind energy, electric vehicles, and real-time market prices are also taken into account. The proposed hourly scheme attempts to mitigate damaging impacts of electricity interruptions by effectively exploiting the MG capabilities. Incorporating AC network constraints in the proposed model offers a better solution to the security-constrained operation of MGs. The proposed model is linearized which offers robustness, simplicity, and computational efficiency in optimizing the MG operation. The effectiveness of proposed approach is illustrated using a large-scale MG test bed with a realistic set of data.
27 March 2009 in IEEE Transactions on Power Delivery
MFMahmud Fotuhi-Firuzabad
This paper investigates the application of immunity genetic algorithm (IGA) for the problem of optimal placement of phasor measurement units (PMUs) in an electric power network. The problem is to determine the placement sites of the minimal set of PMUs which makes the system observable. Incorporating immune operator in the canonical genetic algorithm (GA), on the condition of preserving GA's advantages, utilizes some characteristics and knowledge of the problems for restraining the degenerative phenomena during evolution, so as to improve the algorithm efficiency. This type of prior knowledge about some parts of optimal solution exists in the PMU placement problem. So, the IGA is adopted in this paper to solve the problem. Also, a new effect which is preventing from familial reproduction is studied which shows an increase in converging speed. The effectiveness of the proposed method is verified via IEEE standard systems and a realistic large-scale power system.
26 February 2016 in IEEE Electrification Magazine
Power grids are supposed to be fault-tolerant, but you doubt the premise when you consider daily outages in more populated parts of the world and more recent brownouts and blackouts globally. Power engineers have been pushing forward the frontiers of power systems, and the hard-fought battle against the darkness is supposed to have been won, but the struggle is by no means over. Indeed, the electricity grid today is faced more intensely with challenging issues concerning cyber and physical system security. The recent blackout in Turkey on 31 March 2015, which knocked out the transportation infrastructure in major cities, causing massive traffic jams, is a testimony to this claim. It also shut down vital services to thousands of offices for several hours, inflicting business and social losses (see Figure 1). Although widespread blackouts are regarded as low-probability events, they carry immense socioeconomic costs. In such events, the burden of responsibility often lies with extreme weather events, cascading failures, or similar low-probability, high-impact incidents. According to a report from the White House Council of Economic Advisors, severe weather is the major cause of power grid outages in the United States. Meanwhile, it is estimated that weather-related power outages cost the American economy more than US$300 billion between 2003 and 2012. The report calls for increased investment to enhance the resilience of the power grid against rising incidences of extreme weather such as thunderstorms, hurricanes, and blizzards predicted by climate models.
25 October 2017 in IEEE Transactions on Power Systems
This paper presents a microgrid (MG) proactive management framework to cope with adverse impacts of extreme windstorms. Upon receiving alerts for the forecasted windstorm, the framework finds a conservative schedule of MG with the minimum number of vulnerable branches in service while total load is served. The schedule ensures the MG normal operation prior to the windstorm while reducing the MG vulnerability at the event onset. The proposed method makes benefit of network reconfiguration, generation reschedule, conservation voltage regulation, optimal parameter settings of droop-controlled units, demand-side resources, and backup generation capacity. A vulnerability index (VI) is defined to assess the effectiveness of the proposed proactive management in reducing the MG vulnerability at the event onset. The proposed model is linearized which guarantees simplicity, robustness, and computational efficiency of the solution. The effectiveness of the proposed method is tested on a real-scale MG against a windstorm.
8 May 2019 in Journal of Modern Power Systems and Clean Energy
Power systems are evolving to the networks with proliferated penetration of renewable energy resources to leverage their environmental and economic advantages. However, due to the stochastic nature of renewables, the management of the rapidly increasing uncertainty and variability in power system planning and operation is of crucial significance. This paper represents a comprehensive overview of power system flexibility as an effective way to maintain the power balance at every moment. Definitions of power system flexibility from various aspects are explained to reach the reliable and economic planning and operation of the power system. The effects of the high penetration of variable energy resources on power systems and the evolution of flexibility in response to renewables are studied. A variety of resources during the flexibility evolutionary transition are introduced and discussed. As an influential flexibility solution in current power systems integrated with renewable resources, market design improvement is widely reviewed in this paper, and required modifications in market design mechanisms are investigated pertaining to various time horizons.