Clemens Bos

Clemens Bos

Auto-generated profile, based on publicly available information

Clemens Bos

Department of Radiology, Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
PSPeter R. Seevinck
Peter R. Seevinck
HLHendrik de Leeuw
Hendrik de Leeuw
CBClemens Bos
Clemens Bos
CBChris J. G. Bakker
Chris J. G. Bakker
In this article, we present a 3D imaging technique, applying center-out RAdial Sampling with Off-Resonance reception, to accurately depict and localize small paramagnetic objects with high positive contrast while suppressing long T2* components. The center-out RAdial Sampling with Off-Resonance reception imaging technique is a fully frequency-encoded 3D ultrashort echo time acquisition method, which uses a large excitation bandwidth and off-resonance reception. By manually introducing an offset, Δf0, to the central reception frequency (f0), the typical radial signal pileup observed in 3D center-out sampling caused by a dipolar magnetic field disturbance can be shifted toward the source of the field disturbance, resulting in a hyperintense signal at the magnetic center of the small paramagnetic object. This was demonstrated both theoretically and using 1D time domain simulations. Experimental verification was done in a gel phantom and in inhomogeneous porcine tissue containing various objects with very different geometry and susceptibility, namely, subvoxel stainless steel spheres, a puncture needle, and paramagnetic brachytherapy seeds. In all cases, center-out RAdial Sampling with Off-Resonance reception was shown to generate high positive contrast exactly at the location of the paramagnetic object, as was confirmed by X-ray computed tomography. Magn Reson Med, 2010.

27 March 2001 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CBClemens Bos
Clemens Bos
JSJohannes H.M. Smits
Johannes H.M. Smits
JZJan J. Zijlstra
Jan J. Zijlstra
WMWil A.M.A. van der Mark
Wil A.M.A. van der Mark
PBPeter J. Blankestijn
Peter J. Blankestijn
WMWillem P.Th.M. Mali
Willem P.Th.M. Mali
MR is a potentially attractive modality for evaluating hemodialysis access anatomy and function. However, the wide range of flow rates in the hemodialysis access complicates interpretation of phase contrast, time‐of‐flight, and even contrast‐enhanced MR angiograms. At high flow rates, signal voids may easily arise at mild narrowings or sharp‐angled anastomoses. A method is proposed which visualizes hemodialysis accesses without flow artifacts. Diluted Gd‐DTPA is hand‐injected directly into the access, while a cuff is used to reduce and subsequently interrupt access flow. Filling of the access is monitored using a fast projection technique with complex subtraction. When filling is satisfactory, a 3D acquisition is started. The feasibility of this selective contrast‐enhanced MR angiography technique is demonstrated in four Cimino‐fistulae and four PTFE grafts. Magn Reson Med 45:557–561, 2001.

2 October 2000 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CBClemens Bos
Clemens Bos
HSHenk F.M. Smits
Henk F.M. Smits
CBChris J.G. Bakker
Chris J.G. Bakker
MVMax A. Viergever
Max A. Viergever
In this study the feasibility of intraarterial contrast administration was investigated. Its use for navigation and treatment evaluation during MR-guided intravascular interventions was explored in phantom and animal experiments. An injection protocol was developed, which accounts for sequence parameters and vessel flow rate. Tracking a bolus of contrast agent was useful to verify the catheter tip position and to assess flow conditions. Compared to intravenous contrast-enhanced magnetic resonance angiography (CE-MRA), selective contrast administration permitted a strongly reduced dose. In two-dimensional (2D) acquisitions overlap of vessels was prevented. Injection and acquisition were easily and accurately synchronized in selective 3D CE-MRA, and a high contrast concentration could be maintained during the entire acquisition. Selective injection is useful in the course of an intervention, to facilitate navigation, provide information on flow conditions, and to evaluate treatment progress repeatedly. Magn Reson Med 44:575–582, 2000.