Xin Shi

Xin Shi

Auto-generated profile, based on publicly available information

Xin Shi

Key Laboratory of Intelligent Control and Optimization for Industrial Equipment of Ministry of Education, Dalian University of Technology, Dalian, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2022 in IEEE Transactions on Human-Machine Systems
Verified
Journal Article
Closed access
XSXin Shi
Xin Shi
ZWZhelong Wang
Zhelong Wang
HZHongyu Zhao
Hongyu Zhao
SQSen Qiu
Sen Qiu
RLRuichen Liu
Ruichen Liu
KTKai Tang
Kai Tang
Gait analysis is a prosperous tool for the clinical evaluation and diagnosis. In this article, a portable gait analysis system based on foot-mounted inertial sensors is established. A threshold-free method using a long short-term memory recurrent neural network is constructed to segment four typical gait phases in a gait sequence for the temporal parameters analysis. Segmentation accuracy reaches over 95% across recruited subjects with distinct gait patterns, which is significantly superior when compared with traditional machine learning methods. The zero-velocity indicator is generated successively according to the segmented sequence to accomplish zero velocity update for the spatial parameter calculation. The accuracy of the proposed system is also validated through the OptiTrack in the lab. The comparison result of the stride length shows that the error between the two systems is less than 2%, which demonstrates that our system can satisfy the demand in the clinical.

23 January 2019 in IEEE Transactions on Human-Machine Systems
Verified
Journal Article
Closed access
ZWZhelong Wang
Zhelong Wang
JWJiaxin Wang
Jiaxin Wang
HZHongyu Zhao
Hongyu Zhao
SQSen Qiu
Sen Qiu
JLJie Li
Jie Li
XSXin Shi
Xin Shi
Motion capture based on wearable inertial sensors is a promising technique for swimmers’ training. To apply motion capture techniques properly, a swimming motion evaluation method based on inertial motion capture technology is proposed. Our proposed method uses a multisensor data fusion algorithm for swimmers’ attitude estimation, and the swimming posture is reconstructed in combination with a human biomechanical model. Furthermore, a comparative experiment between our proposed motion capture system and the NDI motion tracking system shows that our system performs reliably and accurately, and the estimation errors are well controlled. In addition, the accuracy of the orientation estimation algorithm ranges from $\text{1.65}^{\circ }$ to $\text{3.66}^{\circ }$ . The system can capture swimmers’ lumbar spine in four competitive swimming styles. A kinematic analysis of lumbar spine movement indicates that the patterns of swimmers’ lumbar spine movement can be used to evaluate training performance and provide quantitative data for swimmers.

26 April 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZWZhelong Wang
Zhelong Wang
JLJie Li
Jie Li
JWJiaxin Wang
Jiaxin Wang
HZHongyu Zhao
Hongyu Zhao
SQSen Qiu
Sen Qiu
XSXin Shi
Xin Shi
A correct riding posture is essential for a good performance in equestrian. This paper proposes a method of equestrian analysis based on body sensor networks. First of all, raw sensor data corresponding to professional (PRO) riders and beginners (BEGs) under different horse gaits were collected by inertial sensor nodes. Then, after an initial sensor alignment with the reduced error, a kind of motion reconstruction method based on the gradient descent method was used to fuse the sensor data to constantly update the rider's attitude information. In addition, to evaluate the tracking accuracy of joint angle, an Northern Digital optical system was deployed to verify the accuracy of our method. Using the attitude information, the motions of riders in equestrian sports were reconstructed by combining the method of human kinematics. Finally, in view of the two aspects of exercise intensity and joint angle, a quantitative analysis of key features between PRO and BEG in walking and rising trot was carried out by combining with the kinematic analysis method. Experiments conducted in this paper demonstrate that the estimation errors are well controlled, and our method can better reflect the similarities and differences between PRO and BEG in equestrian sports and provide quantitative data for equestrian coaches or riders, which can be used to improve the riding skills of riders.

11 May 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
RLRuichen Liu
Ruichen Liu
ZWZhelong Wang
Zhelong Wang
SQSen Qiu
Sen Qiu
HZHongyu Zhao
Hongyu Zhao
CWCui Wang
Cui Wang
FLFang Lin
Fang Lin
For the purpose of quantitative analysis, this paper proposes a wearable gait analysis method for Parkinson’s disease (PD) to evaluates the motor ability. The error state Kalman filter (ESKF) is used for attitude estimation, and the gait parameters are modified by phase segmentation and zero velocity update (ZUPT) algorithm. In addition, this study uses gait parameters as classifier features to recognize abnormal gait, and compares the recognition effect with statistical features. The effect of our gait system is verified by comparison with the OptiTrack system, and the mean absolute error (MAE) of step length and foot clearance are 2.52 $\pm$ 3.61 cm and 0.96 $\pm$ 1.24 cm respectively. Forty Parkinson’s patients and forty age-matched healthy people are recruited for gait comparison, the analysis results showed significant differences between the two groups. The abnormal gait recognition results show that gait features have stronger generalization ability than statistical features in leave-one-subject-out (LOSO) validation. The method proposed in this study can be applied to the gait analysis and objective evaluation of PD.

25 May 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JLJie Li
Jie Li
ZWZhelong Wang
Zhelong Wang
SQSen Qiu
Sen Qiu
HZHongyu Zhao
Hongyu Zhao
QWQiong Wang
Qiong Wang
XSXin Shi
Xin Shi
Evaluation of motor ability of children with Cerebral palsy (CP) based on International Classification of Functioning, Disability and Health for Children and Youth (ICF-CY) framework is an effective way to evaluate exercise rehabilitation therapy at present. Spastic diplegia (SD) is a common symptom in children with CP, which can cause movement disorders and physical disability of lower limbs. To rehabilitate these children, it is important to assess their exercise level in different treatment stages. In this study, an effective method of motion measurement based on inertial sensor network is proposed to evaluate the children’s motor ability in the purpose of the therapy effectiveness validation for the CP children. Extend Kalman filter (EKF) is used to fuse the sensor signals to measure the motion of body segments whose accuracy is verified by OptiTrack optical system. A novel kinetic model based on skeletal vector is proposed to reconstruct the posture of children in sports training to evaluate the effect of exercise rehabilitation. Statistical analysis is deployed to analyze the rehabilitation of motor function corresponding to SD children. The results are encouraging, some children’s motor functions of lower limbs have been improved post-rehabilitation training.

7 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HZHongyu Zhao
Hongyu Zhao
ZQZhibo Qiu
Zhibo Qiu
DPDaoyong Peng
Daoyong Peng
FWFang Wang
Fang Wang
ZWZhelong Wang
Zhelong Wang
QCQinghao Chu
Qinghao Chu
Wearable exoskeletons can help people with mobility impairments by improving their rehabilitation. As electromyography (EMG) signals occur before movement, they can be used as input signals for the exoskeletons to predict the body’s movement intention. In this paper, the OpenSim software is used to determine the muscle sites to be measured, i.e., rectus femoris, vastus lateralis, semitendinosus, biceps femoris, lateral gastrocnemius, and tibial anterior. The surface electromyography (sEMG) signals and inertial data are collected from the lower limbs while the human body is walking, going upstairs, and going uphill. The sEMG noise is reduced by a wavelet-threshold-based complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) reduction algorithm, and the time-domain features are extracted from the noise-reduced sEMG signals. Knee and hip angles during motion are calculated using quaternions through coordinate transformations. The random forest (RF) regression algorithm optimized by cuckoo search (CS), shortened as CS-RF, is used to establish the prediction model of lower limb joint angles by sEMG signals. Finally, root mean square error (RMSE), mean absolute error (MAE), and coefficient of determination (R2) are used as evaluation metrics to compare the prediction performance of the RF, support vector machine (SVM), back propagation (BP) neural network, and CS-RF. The evaluation results of CS-RF are superior to other algorithms under the three motion scenarios, with optimal metric values of 1.9167, 1.3893, and 0.9815, respectively.