8 May 2015 in Lab on a Chip
The emergence of rapid, user-friendly, point-of-care (POC) diagnostic systems is paving the way for better disease diagnosis and control. Lately, there has been a strong emphasis on developing molecular-based diagnostics due to their potential for greatly increased sensitivity and specificity. One of the most critical steps in developing practical diagnostic systems is the ability to perform sample preparation, especially the purification of nucleic acids (NA), at the POC. As such, we have developed a simple-to-use, inexpensive, and disposable sample preparation system for in-membrane purification and concentration of NAs. This system couples lateral flow in a porous membrane with chitosan, a linear polysaccharide that captures NAs via anion exchange chromatography. The system can also substantially concentrate the NAs. The combination of these capabilities can be used on a wide range of sample types, which are prepared for use in downstream processes, such as qPCR, without further purification.
25 February 2021 in Analytical Chemistry
The rapid onset of the global COVID-19 pandemic has led to challenges for accurately diagnosing the disease, including supply shortages for sample collection, preservation, and purification. Currently, most diagnostic tests require RNA extraction and detection by RT-PCR; however, extraction is expensive and time-consuming and requires technical expertise. With these challenges in mind, we report extraction-free, multiplexed amplification of SARS-CoV-2 RNA from 246 clinical samples, resulting in 86% sensitivity and 100% specificity. The multiplex RT-PCR uses the CDC singleplex targets and has an LoD of 2 c/μL. We also report on amplification using a range of master mixes in different transport media. This work can help guide which combinations of reagents will enable accurate results when availability of supplies changes throughout the pandemic. Implementing these methods can reduce complexity and cost, minimize reagent usage, expedite time to results, and increase testing capacity.
30 January 2020 in Analytical Chemistry
Immunoassays are important for the detection of proteins to enable disease identification and monitor treatment, but many immunoassays suffer from sensitivity limitations. The development of digital assays has enabled highly sensitive biomarker detection and quantification, but the necessary devices typically require precisely controlled volumes to reduce biases in concentration estimates from compartment size variation. These constrains have led to systems that are often expensive, cumbersome, and challenging to operate, confining many digital assays to centralized laboratories. To overcome these limi-tations, we have developed a simplified digital immunoassay performed in polydisperse droplets that are prepared without any specialized equipment. This polydisperse digital droplet immunoassay (ddIA) uses proximity ligation to remove the need for wash steps and simplifies the system to a single reagent addition step. Using interleukin-8 (IL-8) as an example ana-lyte, we demonstrated the concept with samples in buffer and diluted whole blood with limits of detection of 0.793 pM and 1.54 pM, respectively. The development of a one-pot, wash-less assay greatly improves usability compared to traditional immunoassays or digital-based systems that rely heavily on wash steps and can be run with common and readily available laboratory equipment such as a heater and simple fluorescent microscope. We also developed a stochastic model with phys-ically meaningful parameters that can be utilized to optimize the assay and enable quantification without standard curves, after initial characterization of the parameters. Our polydisperse ddIA assay serves as an example of sensitive, lower-cost, and simpler immunoassays suitable for both laboratory and point-of-care applications
9 July 2018 in Analytical Chemistry
Nucleic acid amplification technology, such as PCR, has enabled highly sensitive and specific disease detection and quantifica-tion, leading to more accurate diagnosis and treatment regimens. Lab-on-a-chip applications have developed methods to parti-tion single biomolecules, such as DNA and RNA, into picoliter-sized droplets. These individual reaction vessels lead to digiti-zation of PCR enabling improved time-to-detection and direct quantification of nucleic acids without a standard curve, therefore simplifying assay analysis. Though impactful, these improvements have generally been restricted to centralized laboratories with trained personnel and expensive equipment. To address these limitations and make this technology more applicable for a variety of settings, we have developed a statistical framework to apply to droplet PCR performed in polydisperse droplets prepared without any specialized equipment. The polydisperse droplet system allows for accurate quantification of ddPCR and RT-ddPCR that is comparable to commercially available systems such as BioRad’s ddPCR. Additionally, this approach is compatible with a range of input sample volumes, extending the assay dynamic range beyond that of commercial ddPCR sys-tems. In this work, we show that these ddPCR assays can reduce overall assay time while still providing quantitative results. We also report a multiplexed ddPCR assay and demonstrate proof-of-concept methods for rapid droplet preparation in multi-ple samples simultaneously. Our simple polydisperse droplet preparation and statistical framework can be extended to a vari-ety of settings for the quantification of nucleic acids in complex samples.
21 May 2018 in The Analyst
We have developed a simple method for preparing small-volume droplets for performing digital culture, allowing for the detection of bacteria.
21 September 2021 in ACS Omega
The global COVID-19 pandemic has created an urgent demand for large numbers of inexpensive, accurate, rapid, point-of-care diagnostic tests. Analyte-based assays are suitably rapid and inexpensive and can be rapidly mass-produced, but for sufficiently accurate performance, they require highly optimized antibodies and assay conditions. We used an automated liquid handling system, customized to handle arrays of lateral flow (immuno)assays (LFAs) in a high-throughput screen, to identify anti-nucleocapsid antibodies that will perform optimally in an LFA. We tested 1021 anti-nucleocapsid antibody pairs as LFA capture and detection reagents with the goal of highlighting pairs that have the greatest affinity for the nucleocapsid protein of SARS-CoV-2 within the LFA format. In contrast to traditional antibody screening methods (e.g., ELISA, bio-layer interferometry), the method described here integrates real-time reaction kinetics with transport in, and immobilization directly onto, nitrocellulose. We have identified several candidate antibody pairs that are suitable for further development of an LFA for SARS-CoV-2.