31 August 2020 in IEEE Open Journal of Industry Applications
This paper presents an overview of the synchronization stability of converter-based resources under a wide range of grid conditions. The general grid-synchronization principles for grid-following and grid-forming modes are reviewed first. Then, the small-signal and transient stability of these two operating modes are discussed, and the design-oriented analyses are performed to illustrate the control impact. Lastly, perspectives on the prospects and challenges are shared.
29 July 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
With an increasing capacity in converter-based generation to the modern power system, a growing demand for such systems to be more grid-friendly has emerged. Consequently, grid-forming converters have been proposed as a promising solution as they are compatible with the conventional synchronous-machine-based power system. However, most research focuses on the grid-forming control during normal operating conditions without considering the fundamental distinction between a grid-forming converter and a synchronous machine when considering its short-circuit capability. Current limitation of grid-forming converters during fault conditions is not well described in the available literature and present solutions often aim to switch the control structure to a grid-following structure during the fault. Yet, for a future converter-based power system with no or little integration of synchronous machines, the converters need to preserve their voltage-mode characteristics and be robust towards weak-grid conditions. To address this issue, this paper discusses the fundamental issue of grid-forming converter control during grid fault conditions and proposes a fault-mode controller which keeps the voltage-mode characteristics of the grid-forming structure while simultaneously limiting the converter currents to an admissible value. The proposed method is evaluated in a detailed simulation model and verified through an experimental test setup.
1 February 2019 in IEEE Transactions on Power Electronics
Grid-connected converters exposed to weak grid conditions and severe fault events are at risk of losing synchronism with the external grid and neighboring converters. This predicament has led to a growing interest in analyzing the synchronization mechanism and developing models and tools for predicting the transient stability of grid-connected converters. This paper presents a thorough review of the developed methods that describe the phenomena of synchronization instability of grid-connected converters under severe symmetrical grid faults. These methods are compared where the advantages and disadvantages of each method are carefully mapped. The analytical derivations and detailed simulation model are verified through experimental tests of three case studies. Steady-state and quasi-static analysis can determine whether a given fault condition results in a stable or unstable operating point. However, without considering the dynamics of the synchronization unit, transient stability cannot be guaranteed. By comparing the synchronization unit to a synchronous machine, the damping of the phase-locked loop is identified. For accurate stability assessment, either nonlinear phase portraits or time-domain simulations must be performed. Until this point, no direct stability assessment method is available which consider the damping effect of the synchronization unit. Therefore, additional work is needed on this field in future research.
29 July 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Increased penetration of converter-based power generation has enforced system operators to require ancillary services from distributed generation in order to support the grid and improve the power system stability and reliability. Recent and next generation of grid codes require asymmetrical current provision during unbalanced faults for optimal voltage support. To address this, based on the highly used flexible positive and negative-sequence control method for current reference generation, this paper presents a general current reference strategy for asymmetrical fault control where a direct and explicit method is proposed to calculate power references and controller gains while simultaneously complying with converter current limitation and fulfilling the next generation of grid code requirements. The proposed method is tested for three distinct asymmetrical grid faults considering the requirements for dynamic voltage support of the recently revised German grid code as well as the next-generation grid codes. It is shown that the proposed method can improve the fault ride-through performance during asymmetrical faults compared to conventional solutions and comply with modern grid code requirements in a general and flexible manner.
17 March 2021 in IEEE Transactions on Power Electronics
Modeling and design-oriented control of transient stability of grid-following converters have attained an increasing interest in recent years. Despite novel nonlinear models enabling a design-oriented enhanced transient stability controller, the focus has so far been limited to study only the synchronization dynamics of the phase-locked loop. To expand upon the knowledge of the large-signal performance and stability, this article proposes a systematic analysis procedure of a grid-following converter under weak-grid conditions and large-signal disturbances including the outer dc-link and ac-side voltage control loops. A reduced-order large-signal model is used to analyze the large-signal nonlinear behavior of the system using the area of the basin of attraction as a measure for large-signal robustness. Here, stabilizing and destabilizing trends for outer-loop controller parameters are given. Through a surrogate-model expensive black-box optimization algorithm, a computational-efficient optimal design of the outer-loop controller parameters is proposed to maximize the large-signal robustness. Finally, a recommendation and a design guideline for converter constraints and outer-loop controller parameters are given. This can be used to identify the influencing parameters for grid-following converters under large-signal disturbances, and as a tool for fast controller optimization toward large-signal robustness.
10 August 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
During severe grid faults, grid-following converters may become unstable and experience loss of synchronization when complying with requirements for low-voltage ride-through capability. This phenomenon is well-described, understood, and modeled for single-converter systems but lacks a modeling framework when extended to multi-converter systems. To fill this gap, this work presents the necessary stability conditions and aggregated reduced-order models for different multi-converter configurations, which can be used to assess the transient synchronization stability of grid-following converters under symmetrical grid faults. The necessary conditions for transient stability and the aggregated models are verified through numerous simulation studies, which verify their high accuracy for large-signal synchronization stability assessment. To that end, the Anholt wind power plant is considered as a case study where the aggregated model is compared to the full operation of a wind farm string containing 9 full-order grid-following converter models. High model accuracy is obtained, and the computational burden associated with the proposed model is reduced with a factor of 100 compared to a full-order representation on the tested system. Accordingly, the presented analysis and proposed modeling are attractive as a screening tool and a convenient approach for early-stage fault analysis of a system design.