Alain Pascal Francés

Alain Pascal Francés

Auto-generated profile, based on publicly available information

Alain Pascal Francés

Laboratório Nacional de Energia e Geologia (LNEG)

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2012 in Journal of Applied Geophysics
Verified
Journal Article
Closed access
MMM.R. Mahmoudzadeh
M.R. Mahmoudzadeh
AFA.P. Francés
A.P. Francés
MLM. Lubczynski
M. Lubczynski
SLS. Lambot
S. Lambot

1 June 2007 in Comptes Rendus. Géoscience
Verified
Journal Article
Open access
M. Hafedh HamzaM. Hafedh Hamza
M. Hafedh Hamza
AAAyed Added
Ayed Added
AFAlain Francés
Alain Francés
RRRamiro Rodríguez
Ramiro Rodríguez
La nappe phréatique côtière de Metline–Ras Jebel–Raf Raf (gouvernorat de Bizerte, côte nord-est de la Tunisie), qui occupe une superficie de 35 km 2 , représente un impératif économique jugé prioritaire, car elle est utilisée dans les domaines de l’irrigation et de la consommation domestique. L’aire de la nappe est occupée essentiellement par des zones agricoles, caractérisées par une utilisation de plus en plus importante des engrais chimiques, qui représentent un risque permanent pour la qualité des eaux souterraines. L’étude de la vulnérabilité à la pollution de cette nappe a été effectuée en appliquant les deux méthodes de vulnérabilité intrinsèques DRASTIC standard et SINTACS, et la méthode de vulnérabilité spécifique à la pollution par les nitrates, SI. Ces différentes méthodes ont été appliquées par les logiciels des systèmes d’information géographique (SIG) ARC/Info et Idrisi. La validité de l’application de ces méthodes à l’étude de la pollution par les nitrates de la nappe en question a été testée, en établissant une comparaison entre la répartition des nitrates dans les eaux de la nappe et la répartition des classes de vulnérabilité. Cela a montré que la méthode la plus valide est la méthode SI.

1 July 2011 in Journal of Hydrology
Verified
Journal Article
Closed access
AFAlain P. Francés
Alain P. Francés
MLMaciek W. Lubczynski
Maciek W. Lubczynski

23 July 2015 in Hydrogeology Journal
Verified
Journal Article
Closed access
PDF file
AFAlain P. Francés
Alain P. Francés
ERElsa C. Ramalho
Elsa C. Ramalho
JFJudite Fernandes
Judite Fernandes
MGMichel Groen
Michel Groen
RHRui Hugman
Rui Hugman
FSFernando A. Monteiro Santos
Fernando A. Monteiro Santos

3 March 2022 in Hydrogeology Journal
Verified
Journal Article
Open access
PDF file
MDMostafa Gomaa Daoud
Mostafa Gomaa Daoud
MLMaciek W. Lubczynski
Maciek W. Lubczynski
ZVZoltán Vekerdy
Zoltán Vekerdy
AFAlain Pascal Francés
Alain Pascal Francés
Integrated hydrological modelling (IHM) can reliably characterize surface-water/groundwater interactions in complex hydrological systems such as hard-rock systems (HRS), located in water-limited environments (WLE). Such HRS-WLE conditions are represented by Sardon catchment (~80 km2) in Spain, where the MODFLOW 6 modelling environment was tested, applying the following improvements as compared to previous works in that catchment: a new conceptual model, driving forces redefined based on remote sensing data, an unstructured Voronoi grid, and, most importantly, a novel cascade-routing and reinfiltration (CRR) concept. In the standard MODFLOW 6, rejected infiltration and groundwater exfiltration have always been considered as sinks (evaporation). However, in reality, that water can not only evaporate but also reinfiltrate back to the subsurface or move as runoff towards drainage water bodies. The CRR improves surface–unsaturated-zone interactions and also surface-water/groundwater interactions. The standard and new capacities of MODFLOW 6 are presented in the transient model of the Sardon catchment, calibrated using 7 years of daily groundwater heads and streamflows. The results showed: the large spatio-temporal variability of the groundwater fluxes, the substantial role of groundwater exfiltration, the low catchment storage, the fast reaction of the water table and streams to rainfall, and the mosaic character of the net recharge. These characteristics are typical for HRS-WLEs with a shallow water table. MODFLOW 6 has many improvements compared to previous MODFLOW versions, so with the proposed CRR concept (still can be improved), the single-environment MODFLOW 6 has modelling capacity comparable with multienvironment IHMs, while being more flexible and more efficient.

17 September 2024 in Hydrogeology Journal
Verified
Journal Article
Open access
PDF file
AFAlain P. Francés
Alain P. Francés
ERElsa C. Ramalho
Elsa C. Ramalho
FSFernando Monteiro Santos
Fernando Monteiro Santos
JLJosé M. Llorente
José M. Llorente
TMTeodora Mateus
Teodora Mateus
AVAmérico da Mata Victorino
Américo da Mata Victorino
The Cunene Province (Southern Angola) is facing recurrent and pluriannual droughts. Surface water supply could be reinforced using the groundwater resources of the multilayered aquifer systems (MAS) hosted in the siliciclastic sediments of the Kalahari Group. The MAS were first identified in the early 2000s in Northern Namibia and recently in the Cunene Province, by studies of the PLANAGEO project based on modern processing and reinterpretation of legacy data from the 1960s and 1970s (electrical resistivity data and deep boreholes). This article presents the results of a time domain electromagnetic (TDEM) survey conducted in the Cunene Province to: (i) contribute to the design of the hydrogeological conceptual model of the transboundary MAS, namely their geometry and extension; (ii) validate the reprocessing of the legacy data; and (iii) guide the future location of boreholes. Results depict the geometry of the sedimentary basin and the characterization of the MAS, with particular emphasis on the intermediate and deep aquifers. The borehole siting, based on the interpretation of the new TDEM data and the legacy data (clay markers in borehole logs), was successful, with a good agreement between estimated and observed horizons of the deep aquifers. However, the presence of clayey layers, a clay-rich matrix in the detrital deposits and saline/brackish groundwater led to uncertainties in the interpretation of the electrical transects. As such, recommendations are made to improve future data collection and mapping of the MAS.