Strong orthogonality to mass spectrometry makes differential ion mobility spectrometry (FAIMS) a powerful tool for isomer separations. However, high FAIMS resolution and 2-D FAIMS/MS peak capacity were overall achieved only with buffers rich in He or H2. That obstructed coupling to Fourier-transform mass spectrometers operating in ultrahigh vacuum, but exceptional m/z resolution and accuracy of FTMS are indispensable for frontline biological and environmental applications. By raising the waveform amplitude to 6 kV, we enabled high FAIMS resolution using solely N2 and thus straightforward integration with any MS platform - here Orbitrap XL with electron transfer dissociation (ETD) option. The initial evaluation for complete histone tails (50 residues) with diverse post-translational modifications on alternative sites demonstrates broad capability to separate and confidently identify the PTM localization variants in middle-down range.
1 April 2005 in Journal of the American Society for Mass Spectrometry
The experimental paradigm of one ion packet release per spectrum severely hinders throughput in broadband ion mobility spectrometry (IMS) systems (e.g., drift tube and traveling wave systems). Ion trapping marginally mitigates this problem, but the duty cycle deficit is amplified when moving to high resolution, long pathlength systems. As a consequence, new multiplexing strategies that maximize throughput while preserving peak fidelity are essential for high-resolution IMS separations [e.g., structures for lossless ion manipulations (SLIMs) and multi-pass technologies]. Currently, broadly applicable deconvolution strategies for Hadamard-based ion multiplexing are limited to a narrow range of modulation sequences and do not fully maximize the ion signal generated during separation across an extended path length. Compared to prior Hadamard deconvolution errors that rely upon peak picking or discrete error classification, the masked deconvolution matrix technique exploits the knowledge that Hadamard transform artifacts are reflected about the central, primary signal [i.e., the true arrival time distribution (ATD)]. By randomly inducing mathematical artifacts, it is possible to identify spectral artifacts simply by their high degree of variability relative to the core ATD. It is important to note that the deweighting approach using the masked deconvolution matrix does not make any assumptions about the underlying transform and is applicable to any multiplexing strategy employing binary sequences. In addition to demonstrating a 100-fold increase in the total number of ions detected, the effective deconvolution of data from 5, 6, 7, and 8-bit pseudo-random sequences expands the utility and efficiency of the SLIM platform.
1 July 2002 in International Journal of Mass Spectrometry
A novel concept for ion spatial peak compression is described, and discussed primarily in the context of ion mobility spectrometry (IMS). Using theoretical and numerical methods, the effects of using non-constant (e.g., linearly varying) electric fields on ion distributions (e.g., an ion mobility peak) is evaluated both in the physical and temporal domains. The application of a linearly decreasing electric field in conjunction with conventional drift field arrangements is shown to lead to a reduction in IMS physical peak width. When multiple ion packets (i.e., peaks) in a selected mobility window are simultaneously subjected to such fields, there is ion packet compression (i.e., a reduction in peak widths for all species). This peak compression occurs with only a modest reduction of resolution, which can be quickly recovered as ions drift in a constant field after the compression event. Compression also yields a significant increase in peak intensities. Ion mobility peak compression can be particularly useful for mitigating diffusion-driven peak broadening over very long path length separations (e.g., in cyclic multi-pass arrangements), and for achieving higher S/N and IMS resolution over a selected mobility range.