12 July 2018 in JCI Insight
To what extent does the subarachnoid cerebrospinal fluid (CSF) compartment communicate directly with the extravascular compartment of human brain tissue? Interconnection between the subarachnoid CSF compartment and brain perivascular spaces is reported in some animal studies, but with controversy, and in vivo CSF tracer studies in humans are lacking. In the present work, we examined the distribution of a CSF tracer in the human brain by MRI over a prolonged time span. For this, we included a reference cohort, representing close to healthy individuals, and a cohort of patients with dementia and anticipated compromise of CSF circulation (idiopathic normal pressure hydrocephalus). The MRI contrast agent gadobutrol, which is confined to the extravascular brain compartment by the intact blood-brain barrier, was used as a CSF tracer. Standardized T1-weighted MRI scans were performed before and after intrathecal gadobutrol at defined time points, including at 24 hours, 48 hours, and 4 weeks. All MRI scans were aligned and brain regions were segmented using FreeSurfer, and changes in normalized T1 signals over time were quantified as percentage change from baseline. The study provides in vivo evidence of access to all human brain subregions of a substance administered intrathecally. Clearance of the tracer substance was delayed in the dementia cohort. These observations translate previous findings in animal studies into humans and open new prospects concerning intrathecal treatment regimens, extravascular contrast-enhanced MRI, and assessment of brain clearance function.
29 April 2010 in Numerical Linear Algebra with Applications
28 August 2017 in Proceedings of the National Academy of Sciences
The brain lacks lymph vessels and must rely on other mechanisms for clearance of waste products, including amyloid that may form pathological aggregates if not effectively cleared. It has been proposed that flow of interstitial fluid through the brain’s interstitial space provides a mechanism for waste clearance. Here we compute the permeability and simulate pressure-mediated bulk flow through 3D electron microscope (EM) reconstructions of interstitial space. The space was divided into sheets (i.e., space between two parallel membranes) and tunnels (where three or more membranes meet). Simulation results indicate that even for larger extracellular volume fractions than what is reported for sleep and for geometries with a high tunnel volume fraction, the permeability was too low to allow for any substantial bulk flow at physiological hydrostatic pressure gradients. For two different geometries with the same extracellular volume fraction the geometry with the most tunnel volume had higher permeability, but the bulk flow was still insignificant. These simulation results suggest that even large molecule solutes would be more easily cleared from the brain interstitium by diffusion than by bulk flow. Thus, diffusion within the interstitial space combined with advection along vessels is likely to substitute for the lymphatic drainage system in other organs. Significance Transport of nutrients and clearance of waste products are prerequisites for healthy brain function. It is still debated whether solutes are transported through the interstitial space by pressure-mediated bulk flow or by diffusion. Here we have simulated interstitial bulk flow within 3D electron microscope reconstructions of hippocampal tissue. We show that the permeability is one to two orders of magnitude lower than values typically seen in the literature, arguing against bulk flow as the dominant transport mechanism. Further, we show that solutes of all sizes are more easily transported through the interstitium by diffusion than by bulk flow. We conclude that clearance of waste products from the brain is largely based on diffusion of solutes through the interstitial space.
1 January 2002 in SIAM Journal on Numerical Analysis
Finite element methods for a family of systems of singular perturbation problems of a saddle point structure are discussed. The system is approximately a linear Stokes problem when the perturbation parameter is large, while it degenerates to a mixed formulation of Poisson's equation as the perturbation parameter tends to zero. It is established, basically by numerical experiments, that most of the proposed finite element methods for Stokes problem or the mixed Poisson's system are not well behaved uniformly in the perturbation parameter. This is used as the motivation for introducing a new "robust" finite element which exhibits this property.
3 January 2017 in SIAM Journal on Scientific Computing
Biot's consolidation model in poroelasticity has a number of applications in science, medicine, and engineering. The model depends on various parameters, and in practical applications these paramet...
1 September 2007 in Stroke
Background and Purpose—
Wall shear stress (WSS) and pressure are important factors in the development of cerebral aneurysms. We aimed to develop a computational fluid dynamics simulator for flow in the complete circle of Willis to study the impact of variations in vessel radii and bifurcation angles on WSS and pressure on vessel walls.
Methods—
Blood flow was modeled with Navier-Stokes equations as an incompressible newtonian fluid within rigid vessel walls. A model of the circle of Willis geometry was approximated as a network of tubes around cubic curves. Pulsatile inlet flow rates and constant outlet pressure were used as boundary conditions.
Results—
The simulations confirmed that differences in vessel radii and asymmetric branch angles influence WSS magnitude and spatial distribution. High WSS occurred at locations where aneurysms are frequent and in anatomic variants known to be associated with an increased risk for aneurysm development.
Conclusions—
Computational fluid dynamics analysis can be applied to the complete circle of Willis and should be used to study the pathophysiology of this complex vascular structure, including risk factors for aneurysm development. Further development of the method should include simulations with flexible vessel walls.