1 January 2018 in IET Power Electronics
In this study, the analysis of a three‐coil wireless power transfer (WPT) system, which can be divided into source, communication and load circuits, is discussed in details. Among the three‐coil WPT systems features, it is demonstrated, for instance, that maximum efficiency ( ) and maximum power transferred to the load ( P 3MAX ) do not depend on the load resistance, neither on the mutual inductance between communication and load coils. In fact, it is shown that and P 3MAX depend only on source and communication circuits parameters. Practical results are also presented, showing good agreement with the developed theory and validating the proposed analysis.
1 June 2012 in Telemedicine and e-Health
CSCecilia H. Vallejos de Schatz
Cecilia H. Vallejos de Schatz
This article analyzes wireless communication protocols that could be used in healthcare environments (e.g., hospitals and small clinics) to transfer real-time medical information obtained from noninvasive sensors. For this purpose the features of the three currently most widely used protocols—namely, Bluetooth® (IEEE 802.15.1), ZigBee (IEEE 802.15.4), and Wi-Fi (IEEE 802.11)—are evaluated and compared. The important features under consideration include data bandwidth, frequency band, maximum transmission distance, encryption and authentication methods, power consumption, and current applications. In addition, an overview of network requirements with respect to medical sensor features, patient safety and patient data privacy, quality of service, and interoperability between other sensors is briefly presented. Sensor power consumption is also discussed because it is considered one of the main obstacles for wider adoption of wireless networks in medical applications. The outcome of this assessment will be a useful tool in the hands of biomedical engineering researchers. It will provide parameters to select the most effective combination of protocols to implement a specific wireless network of noninvasive medical sensors to monitor patients remotely in the hospital or at home.
4 January 2008 in IEEE Sensors Journal
SPSérgio Francisco Pichorim
Sérgio Francisco Pichorim
Resonant passive sensors composed by resistive, inductive, and capacitive (RLC) simple sensors are widely used in biotelemetric systems. In this paper, a novel method to read remotely these RLC sensors is presented. The developed method is based on the simultaneous application of three excitation signals of same amplitudes, set at different frequencies, to determine remotely the RLC sensor resonance frequency and quality factor . Theoretical analysis and experimental results are also presented.
1 November 2010 in Review of Scientific Instruments
In this paper, a novel and simple method to measure the phase difference between two sinusoidal signals is presented. Basically, the method consists of subtracting two sinusoidal signals with same frequencies and measuring the resulting signal amplitude: this amplitude being a minimum whenever there is a coincidence between both signal phases. In order to test this method, an adjustable phase reference signal has been generated using a direct digital synthesizer device. Employing this reference signal, it can be demonstrated that the phase difference between two signals can be evaluated with errors smaller than 0.3° for signals with frequencies up to 1.25 MHz.
16 January 2008 in IEEE Transactions on Biomedical Engineering
The electrical characteristics of the sparks produced between the active electrode and the biological tissue during electrosurgical procedures have been experimentally investigated. The results have shown that the minimum voltage required to initiate a spark depends on the applied voltage polarity resulting in electrosurgical voltage asymmetry. This voltage asymmetry is capable of producing DC levels that can result in tissue electrostimulation or direct current burns as discussed in this paper. The experimental setup and the conditions, under which the results have been obtained, including the techniques used to improve experimental reproducibility, are reported in detail.
1 June 2015 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
The condition for maximum power transfer of 2-coils wireless power transfer (WPT) system is derived from circuit analysis and discussed together with the respective WPT system efficiency (η). In the sequence, it is shown that a 4-coils WPT system (which can be divided in source, two communication and load circuits) without power losses at the two communication circuits (ideal 4-coils WPT system) presents, from maximum power transfer and efficiency point of view, a performance similar to those of a 2-coils WPT system. The exception is the influence of coupling coefficient (k): in 2-coils system η increases as k approaches one, while in ideal 4-coils WPT system η increases as k between the two communication coils approaches zero. In addition, realistic 4-coils WPT systems (with power losses at the two communication circuits) are also analyzed showing, for instance, that η presents a maximum as a function of k of the communication coils. In order to validate the presented theory, 4 coils were built, and a setup to perform 2-coils and 4-coils WPT systems has been carried out. Practical results show good agreement with the developed theory.