Stephanie A. Pierce

Stephanie A. Pierce

Auto-generated profile, based on publicly available information

Stephanie A. Pierce

Department of Bioengineering, University of Colorado Anschutz Medical Campus 3 , Aurora, Colorado 80045

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SMStephanie A. Meyer
Stephanie A. Meyer
BOBaris N. Ozbay
Baris N. Ozbay
MPMariana Potcoava
Mariana Potcoava
ESErnesto Salcedo
Ernesto Salcedo
DRDiego Restrepo
Diego Restrepo
EGEmily A. Gibson
Emily A. Gibson
We performed stimulated emission depletion (STED) imaging of isolated olfactory sensory neurons (OSNs) using a custom-built microscope. The STED microscope uses a single pulsed laser to excite two separate fluorophores, Atto 590 and Atto 647N. A gated timing circuit combined with temporal interleaving of the different color excitation/STED laser pulses filters the two channel detection and greatly minimizes crosstalk. We quantified the instrument resolution to be ∼81 and ∼44  nm, for the Atto 590 and Atto 647N channels. The spatial separation between the two channels was measured to be under 10 nm, well below the resolution limit. The custom-STED microscope is incorporated onto a commercial research microscope allowing brightfield, differential interference contrast, and epifluorescence imaging on the same field of view. We performed immunolabeling of OSNs in mice to image localization of ciliary membrane proteins involved in olfactory transduction. We imaged Ca2+-permeable cyclic nucleotide gated (CNG) channel (Atto 594) and adenylyl cyclase type III (ACIII) (Atto 647N) in distinct cilia. STED imaging resolved well-separated subdiffraction limited clusters for each protein. We quantified the size of each cluster to have a mean value of 88±48  nm and 124±43  nm, for CNG and ACIII, respectively. STED imaging showed separated clusters that were not resolvable in confocal images.

1 March 2022 in APL Photonics
Verified
Journal Article
Open access
PDF file
BHBrendan M. Heffernan
Brendan M. Heffernan
PRPeter S. Riley
Peter S. Riley
OSOmkar D. Supekar
Omkar D. Supekar
SMStephanie A. Meyer
Stephanie A. Meyer
DRDiego Restrepo
Diego Restrepo
JGJuliet T. Gopinath
Juliet T. Gopinath
Imaging sub-diffraction dynamics of neural nanostructures involved in behaviors such as learning and memory in a freely moving animal is not possible with existing techniques. Here, we present a solution in the form of a two-photon (2P), fiber-coupled, stimulated emission depletion microscope and demonstrate its capabilities by acquiring super-resolution imaging of mammalian cells. A polarization-maintaining fiber is used to transport both the 2P excitation light (915 nm) and the donut-shaped depletion beam (592 nm), which is constructed by adding two temporally incoherent and orthogonally polarized Hermite–Gaussian fiber modes. The fiber output is insensitive to bending or temperature changes and is the first demonstration toward deep tissue super-resolution imaging in awake behaving animals.

1 March 2026 in APL Photonics
Verified
Journal Article
Open access
PDF file
JGJuliet T. Gopinath
Juliet T. Gopinath
EGEmily A. Gibson
Emily A. Gibson
BHBrendan M. Heffernan
Brendan M. Heffernan
SPStephanie A. Pierce
Stephanie A. Pierce
CSCatherine A. Saladrigas
Catherine A. Saladrigas
DRDiego Restrepo
Diego Restrepo
Recent advances in stimulated emission depletion (STED) microscopy have resulted in breakthroughs in biological imaging. Such advances include three-dimensional (3D) imaging, aberration correction to enhance resolution at depth in tissue, reduction in photobleaching, and label-free STED-inspired alternatives, enabling in vivo applications. In this perspective, we first summarize the basic principles of stimulated emission depletion microscopy and its major challenges. Next, we discuss techniques to reduce photobleaching, 3D imaging with STED, deep tissue imaging with STED, fiber-coupled STED, live animal imaging, and label-free imaging with super-resolution. Finally, we summarize and provide perspectives for future research.

12 June 2024 in Neurophotonics
Verified
Journal Article
Open access
PDF file
SPStephanie A. Pierce
Stephanie A. Pierce
JJJordan Jacobelli
Jordan Jacobelli
KGKatherine S. Given
Katherine S. Given
WMWendy B. Macklin
Wendy B. Macklin
JGJuliet T. Gopinath
Juliet T. Gopinath
EGEmily A. Gibson
Emily A. Gibson
SignificanceStimulated emission depletion (STED) is a powerful super-resolution microscopy technique that can be used for imaging live cells. However, the high STED laser powers can cause significant photobleaching and sample damage in sensitive biological samples. The dynamic intensity minimum (DyMIN) technique turns on the STED laser only in regions of the sample where there is fluorescence signal, thus saving significant sample photobleaching. The reduction in photobleaching allows higher resolution images to be obtained and longer time-lapse imaging of live samples. A stand-alone module to perform DyMIN is not available commercially.AimIn this work, we developed an open-source design to implement three-step DyMIN on a STED microscope and demonstrated reduced photobleaching for timelapse imaging of beads, cells, and tissue.ApproachThe DyMIN system uses a fast multiplexer circuit and inexpensive field-programmable gate array controlled by Labview software that operates as a stand-alone module for a STED microscope. All software and circuit diagrams are freely available.ResultsWe compared time-lapse images of bead samples using our custom DyMIN system to conventional STED and recorded a ∼46% higher signal when using DyMIN after a 50-image sequence. We further demonstrated the DyMIN system for time-lapse STED imaging of live cells and brain tissue slices.ConclusionsOur open-source DyMIN system is an inexpensive add-on to a conventional STED microscope that can reduce photobleaching. The system can significantly improve signal to noise for dynamic time-lapse STED imaging of live samples.