Imaging methodologies such as, computed tomography (CT) aid in three-dimensional (3D) reconstruction of patient-specific aneurysms. The radiological data is useful in understanding their location, shape, size, and disease progression. However, there are serious impediments in discerning the blood vessel wall thickness due to limitations in the current imaging modalities. This further restricts the ability to perform high-fidelity fluid structure interaction (FSI) studies for an accurate assessment of rupture risk. FSI studies would require the arterial wall mesh to be generated to determine realistic maximum allowable wall stresses by performing coupled calculations for the hemodynamic forces with the arterial walls. In the present study, a novel methodology is developed to geometrically model variable vessel wall thickness for the lumen isosurface extracted from CT scan slices of patient-specific aneurysms based on clinical and histopathological inputs. FSI simulations are carried out with the reconstructed models to assess the importance of near realistic wall thickness model on rupture risk predictions. During surgery, clinicians often observe translucent vessel walls, indicating the presence of thin regions. The need to generate variable vessel wall thickness model, that embodies the wall thickness gradation, is closer to such clinical observations. Hence, corresponding FSI simulations performed can improve clinical outcomes. Considerable differences in the magnitude of instantaneous wall shear stresses and von Mises stresses in the walls of the aneurysm was observed between a uniform wall thickness and a variable wall thickness model. In the present study, a variable vessel wall thickness generation algorithm is implemented. It was shown that, a realistic wall thickness modeling is necessary for an accurate prediction of the shear stresses on the wall as well as von Mises stresses in the wall. FSI simulations are performed to demonstrate the utility of variable wall thickness modeling.
Damping elements are used in ships and offshore structures as response reduction devices for maintaining the hydrodynamic response within acceptable limits. The use of such elements so far has been based on past experience or using empirical based design approach. An investigation of the wave excitation forces acting on these structures with and without damping elements may give an insight into the damping effects of such elements. Also understanding the flow pattern and the magnitude of flow variation around these elements may be useful to improve the design methods. In the present study, measurement of damping forces and response were carried out to establish the relationship between wave frequency amplitude and damping ratio. It was observed that the damping varies with wave period non-linearly and linearly with wave height. Also it was observed that increase in added mass combined with viscous damping is a key factor for the effectiveness of heave plates in reducing motion response of spar platforms. Of the various configurations tested, the spar with double heave plate at the bottom has higher damping compared to other configurations.