Jay Burmeister

Jay Burmeister

Auto-generated profile, based on publicly available information

Jay Burmeister

Department of Oncology, Wayne State University School of Medicine, Karmanos Cancer Center, Detroit, MI, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2010 in Medical Physics
Verified
Journal Article
Closed access
MJMichael C. Joiner
Michael C. Joiner
NMNagaraju Mogili
Nagaraju Mogili
BMBrian Marples
Brian Marples
JBJay Burmeister
Jay Burmeister

9 September 2023 in Clinical and Translational Radiation Oncology
Verified
Journal Article
Open access
DPDavid Donald Mortimer Parsons
David Donald Mortimer Parsons
TLTze Yee Lim
Tze Yee Lim
JTJose R. Teruel
Jose R. Teruel
PGPaulina Galavis
Paulina Galavis
SAStefano Agostinelli
Stefano Agostinelli
GKGrace Gwe-Ya Kim
Grace Gwe-Ya Kim
• Seven centres process of intensity modulated total body irradiation. • Six centres process of intensity modulated total marrow irradiation. • Tables were designed from the typical questions the authors received from centres starting an intensity modulated program. • The work is designed to springboard for centers considering implementing these techniques.

24 January 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
MSMubin Y. Shaikh
Mubin Y. Shaikh
MJMichael C. Joiner
Michael C. Joiner
ANAdrian Nalichowski
Adrian Nalichowski
LKLalith K. Kumaraswamy
Lalith K. Kumaraswamy
JBJay Burmeister
Jay Burmeister
Introduction: INTRABEAM x‐ray sources (XRSs) have distinct output characteristics due to subtle variations between the ideal and manufactured products. The objective of this study is to intercompare 15 XRSs and to dosimetrically quantify the impact of manufacturing variations on the delivered dose.Methods and Materials: The normality of the XRS datasets was evaluated with the Shapiro–Wilk test, the accuracy of the calibrated depth–dose curves (DDCs) was validated with ionization chamber measurements, and the shape of each DDC was evaluated using depth–dose ratios (DDRs). For 20 Gy prescribed to the spherical applicator surface, the dose was computed at 5‐mm and 10‐mm depths from the spherical applicator surface for all XRSs.Results: At 5‐, 10‐, 20‐, and 30‐mm depths from the source, the coefficient of variation (CV) of the XRS output for 40 kVp was 4.4%, 2.8%, 2.0%, and 3.1% and for 50 kVp was 4.2%, 3.8%, 3.8%, and 3.4%, respectively. At a 20‐mm depth from the source, the 40‐kVp energy had a mean output in Gy/Minute = 0.36, standard deviation (SD) = 0.0072, minimum output = 0.34, and maximum output = 0.37 and a 50‐kVp energy had a mean output = 0.56, SD = 0.021, minimum output = 0.52, and maximum output = 0.60. We noted the maximum DRR values of 2.8% and 2.5% for 40 kVp and 50 kVp, respectively. For all XRSs, the maximum dosimetric effect of these variations within a 10‐mm depth of the applicator surface is ≤ 2.5%. The CV increased as depth increased and as applicator size decreased.Conclusion: The American Association of Physicist in Medicine Task Group‐167 requires that the impurities in radionuclides used for brachytherapy produce ≤ 5.0% dosimetric variations. Because of differences in an XRS output and DDC, we have demonstrated the dosimetric variations within a 10‐mm depth of the applicator surface to be ≤ 2.5%.

1 May 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KHKristi R. G. Hendrickson
Kristi R. G. Hendrickson
TJTitania Juang
Titania Juang
ARAnna E. Rodrigues
Anna E. Rodrigues
JBJay W. Burmeister
Jay W. Burmeister
Purpose The purpose of this study was to gauge the experiences of applicants and program directors (PDs) in the Medical Physics (MedPhys) Match (MPM) and to determine the most important characteristics and factors that influence decision-making for applicants and programs when screening, interviewing, and ranking in the MPM. Opinions were also solicited from applicants and PDs on the status of medical physics residencies and the selection process, such as the availability of residency positions and satisfaction with the match process. Methods A survey was sent to all applicants registered for the 2015-2018 MPM and to all PDs registered for the 2015-2017 MPM. Survey questions asked about the pre-interview screening, interview, and ranking stages of the residency match process. Survey data were analyzed using graphical methods and spreadsheet tools. Results An increasing percentage of applicants are female and/or hold a PhD as their highest degree. The over all number of interview invitations per applicant has increased, leading some applicants to decline interviews with the top reasons being cost of travel and scheduling conflicts. The top considerations for applicants in ranking programs were residency program/institution reputation, program structure/organization, and facilities/equipment available. The primary considerations identified by PDs for ranking applicants included impressions from the interview, personality fit, and clinical potential. While two-thirds of applicants agreed or strongly agreed with the statement that a residency position was difficult to obtain, roughly one-third of PDs agree that the current residency placement rate is a problem. Conclusion Four years of survey data on the experiences of applicants and PDs participating in the MPM is useful to future participants navigating the residency match system. It is hoped that the data will be helpful to inform improvements and to enhance understanding of the residency match system and how it shapes our profession.

24 November 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ANIS AHMADANIS AHMAD
ANIS AHMAD
LSLakshmi Santanam
Lakshmi Santanam
ASAbhishek Ashok Solanki
Abhishek Ashok Solanki
LPLaura Padilla
Laura Padilla
EVErina Vlashi
Erina Vlashi
MJMichael C. Joiner
Michael C. Joiner
Click on the article title to read more.

1 November 2026 in Physica Medica
Verified
Journal Article
Closed access
LLLuke Layman
Luke Layman
JBJay Burmeister
Jay Burmeister
RBRamesh Boggula
Ramesh Boggula