Ariel Roitman

Ariel Roitman

Auto-generated profile, based on publicly available information

Ariel Roitman

Department of Otolaryngology - Head and Neck Surgery, Carmel Medical Center, Haifa, Israel; The Ruth and Bruce Rappaport Faculty of Medicine, Technion - Israel Institute of Technology, Haifa, Israel

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2022 in Ear, Nose & Throat Journal
Verified
Journal Article
Open access
IMItai Margulis
Itai Margulis
RCRaanan Cohen-Kerem
Raanan Cohen-Kerem
ARAriel Roitman
Ariel Roitman
HGHadar Gez-Reder
Hadar Gez-Reder
AAAriel Aviram
Ariel Aviram
IDIlana Doweck
Ilana Doweck
Objective: To examine associations of laboratory and imaging data with diagnostic parameters of necrotizing otitis externa (NOE) and its severity, and to compare between bacterial and fungal infections. Methods: Records of patients diagnosed with NOE during 2010–2018 at the Department of Otolaryngology, Head and Neck Surgery were reviewed retrospectively for demographics; disease characteristics; and laboratory, scintigraphy, and imaging results. Results: Of 48 patients with NOE, the mean age is 73±11.6 years; 32 (67%) were males; 83% had diabetes mellitus. Common pathogens were pseudomonas (49%) and fungi (33%). Sensitivities of the technetium-scan (SPECT ratio ≥1.5), temporal bone computed tomography (CT), and gallium-scan (SPECT ratio ≥1.3) were: 78.7%, 48.8%, and 31.4%, respectively. Gallium-scan results correlated positively with CT bone involvement (p=0.002) and hospital length of stay (p=0.0014). C-reactive protein (CRP) level correlated with hospital length of stay (p=0.028) and positive technetium-scan results (p=0.012). Fungal infection had a higher technetium SPECT ratio (2.16 vs. 1.77, p=0.04), gallium SPECT ratio (1.4 vs. 1.2, p=0.02), longer duration of systemic treatment (87.4 vs. 37.9 days, p=0.014), and longer hospital length of stay (31.6 vs. 15.2 days, p=0.004) compared to non-fungal infection. Eight (17%) patients had responded poorly to treatment. Fungal pathogens, facial nerve paresis, extra-auricular, and bilateral disease were more prevalent among the non-responders. Conclusion: The technetium scan has higher sensitivity than temporal bone CT for diagnosing NOE. The gallium scan and CRP correlated well with hospital length of stay. A high rate of fungal infection was found, with significantly higher technetium and gallium SPECT ratios and worse outcome compared to bacterial infection. Fungal NOE remains therapeutically challenging.

24 February 2016 in European Journal of Plastic Surgery
Verified
Journal Article
Closed access
PDF file
ARAriel Roitman
Ariel Roitman
MLMichal Luntz
Michal Luntz
YHYaron Har-Shai
Yaron Har-Shai

6 December 2024 in The Laryngoscope
Verified
Journal Article
Open access
ARAriel Roitman
Ariel Roitman
TLTadeas Lunga
Tadeas Lunga
AVAnumitha Venkatraman
Anumitha Venkatraman
KSKristopher M Schroeder
Kristopher M Schroeder
STSusan L Thibeault
Susan L Thibeault
SDSeth H Dailey
Seth H Dailey
Introduction: The risk of fire during laser microlaryngoscopy is well known. However, limited information is available about fire risk with the novel TruBlue laser. This study systematically evaluates its interactions with common surgical supplies, offering valuable insights into safety considerations for surgeons. Material and Methods: We used experimental conditions to test the extent to which TruBlue laser energy produces smoke, perforation, or fire in Rüsch®, Medtronic™ and microlaryngeal endotracheal tubes and in surgical pledgets. Results: Only the Microlaryngeal Tube (MLT) caught fire. Notably, it happened only when the laser fiber shifted on the tube's surface. Smoke emerged solely from the laser fiber applied to the Medtronic™ shaft and only during continuous contact mode. Cuff perforation and smoke emanating from the shaft occurred in three‐quarters of the Rüsch® trials. The pledgets' radiopaque segment exhibited a greater combustibility than other segments ( p < 0.01). In many of the pledget trials, faster smoke emission occurred with shorter laser‐to‐target distances ( p < 0.05). Water‐soaked pledgets displayed a reduced rate of smoke production ( p < 0.01) and string division. Conclusion: The Medtronic™ tube assures remarkable safety with a nonignitable shaft and low cuff ignition. The MLT poses the highest ignition risk. Cuff perforation risk is mitigated by maintaining a 0.3‐cm distance from the laser fiber tip. Pledget fire risk is mitigated by positioning the radiopaque part away from the laser beam and by soaking the pledget with water. Laser division of the pledgets' string was common. Level of Evidence: NA Laryngoscope , 135:1752–1758, 2025

24 August 2025 in The Laryngoscope
Verified
Journal Article
Open access
ARAriel Roitman
Ariel Roitman
SDSeth H. Dailey
Seth H. Dailey
MWMarcus Wilson
Marcus Wilson
ABAndrew J. Bowen
Andrew J. Bowen
KSKristopher M. Schroeder
Kristopher M. Schroeder
STSusan L. Thibeault
Susan L. Thibeault
Introduction: The potential for airway fire during endoscopic laser surgery is well known, typically addressed by reducing FiO 2 levels. This study revisits these established practices in CO 2 laser tubeless airway surgery. Materials and Methods: Using a cadaveric porcine larynx and lung model, we conducted trials with high‐flow (HFV) and jet ventilation. We varied FiO 2 levels and laser power settings to record the onset and number of brief, expansive, and blowtorch flames. Results: Flames were observed in all jet ventilation trials. Multivariable model results showed that increasing laser wattage decreased onset times for expansive/blowtorch flames and increased their frequency ( p < 0.05). Increased FiO 2 changes were not significant ( p > 0.05). HFV trials revealed no expansive flames at 4 W at 100%, 6 W at 70%, and 10 W at 50% FiO 2 . Increasing wattage shortened flame onset and increased frequency across all flames ( p < 0.01), while increasing FiO 2 only reduced onset time for brief flames ( p < 0.05). Jet ventilation led to higher flame incidence and shorter onset times than HFV ( p < 0.05). Conclusion: Fire risk during CO 2 laser surgery in oxygen‐rich environments is influenced more by wattage, rather than FiO 2 levels. Jet ventilation consistently produced expansive flames, even at lower FiO 2 levels and wattage, supporting a FiO 2 limit of 30% for this ventilation technique. Our findings support HFV as a potentially safer option for CO 2 laser surgery, with safe zones of 4 W at 100%, 6 W at 70%, and 10 W at 50% FiO 2 , provided laser application is under 30 s. Our model's calculation of excess risk from wattage increments can help surgeons assess this fire risk.

17 July 2025 in The Laryngoscope
Verified
Journal Article
Open access
ARAriel Roitman
Ariel Roitman
MWMarcus Wilson
Marcus Wilson
ABAndrew J. Bowen
Andrew J. Bowen
KSKristopher M. Schroeder
Kristopher M. Schroeder
STSusan L. Thibeault
Susan L. Thibeault
SDSeth H. Dailey
Seth H. Dailey
Objectives: Fire risk during laser airway surgery is well‐documented, but there is limited information regarding this risk with the novel TruBlue laser. This study evaluates its safety under different experimental conditions. Methods: Using a cadaveric porcine larynx and lungs model, we conducted trials with laser‐safe endotracheal tubes (LSETTs), high‐flow ventilation (HFV), and jet ventilation. We varied distance, FiO 2 levels, and laser power settings to observe the occurrence of uncontrolled fires, brief flames, and sparks. Results: LSETT trials showed no fire events. Pledget fires were the only uncontrolled fires in HFV, at 100%, 70%, and 50% FiO 2 . Brief flames occurred only with 4 W continuous settings at 100% FiO 2 . Innocuous spark ignition rates were significantly increased by increased wattage ( p < 0.05). In jet ventilation trials, brief flames appeared across a wider range of FiO 2 levels and settings. HFV and jet ventilation groups showed a greater frequency and earlier occurrence of sparks and brief flames, in contrast to the event‐free LSETT group ( p < 0.05). Conclusion: Using the TruBlue laser with a fully inflated LSETT cuff positioned at least 0.3 cm below the operating area while delivering 100% oxygen was consistently safe in our trials. Uncontrolled fires occurred only when targeting a pledget under HFV, confirming extrinsic fuel as the main risk and highlighting the safety of the TruBlue laser with HFV and jet ventilation in its absence. Compared to HFV, jet ventilation trials showed a higher frequency of brief flames and sparks. A 60‐s continuous application of the laser at 100% FiO 2 is safe. Level of Evidence: NA.