26 December 2022 in Nature Communications
Magnetic resonance imaging (MRI) is a non-invasive imaging technology to diagnose health conditions, showing the weakness of low sensitivity. Herein, we synthesize a contrast agent, SPIO@SiO2@MnO2, which shows decreased T1 and T2 contrast intensity in normal physiological conditions. In the acid environment of tumor or inflamed tissue, the manganese dioxide (MnO2) layer decomposes into magnetically active Mn2+ (T1-weighted), and the T1 and T2 signals are sequentially recovered. In addition, both constrast quenching-activation degrees of T1 and T2 images can be accurately regulated by the silicon dioxide (SiO2) intermediate layer between superparamagnetic iron oxide (SPIO) and MnO2. Through the “dual-contrast enhanced subtraction” imaging processing technique, the contrast sensitivity of this MRI contrast agent is enhanced to a 12.3-time difference between diseased and normal tissue. Consequently, SPIO@SiO2@MnO2 is successfully applied to trace the tiny liver metastases of approximately 0.5 mm and monitor tissue inflammation.
1 January 2020 in Journal of Clinical Neurology
Previous studies have explored the association between retinal vascular changes and cognitive impairment. The retinal vasculature shares some characteristics with the cerebral vasculature, and quantitative changes in it could indicate cognitive impairment. Hence, a comprehensive meta-analysis was performed to clarify the potential relationship between retinal vascular geometric changes and cognitive impairment. Relevant databases were scrupulously and systematically searched for retinal vascular geometric changes including caliber, tortuosity, and fractal dimension (FD), and for cognitive impairment. The Newcastle-Ottawa Scale was used to evaluate the methodological quality of included studies. RevMan was used to perform the meta-analysis and detect publication bias. Sensitivity analyses were also performed. Five studies that involved 2,343 subjects were finally included in the meta-analysis. The results showed that there was no significant association between central retinal artery equivalents (Z=1.17) or central retinal venular equivalents (Z=1.74) and cognitive impairment (both p>0.05). Similarly, no significant difference was detected in retinal arteriolar tortuosity (Z=0.91) and venular tortuosity (Z=1.31) (both p>0.05). However, the retinal arteriolar FD (mean difference: -0.03, 95% CI: -0.05, -0.01) and venular FD (mean difference: -0.03, 95% CI: -0.05, -0.02) were associated with cognitive impairment. A smaller retinal microvascular FD might be associated with cognitive impairment. Further large-sample and well-controlled original studies are required to confirm the present findings.