Purpose. Investigate the influence of uncontrolled gas components in the atmosphere on the operation of thermocatalytic sensors in explosion hazard monitoring systems for man-made facilities. Methodology. The work applies experimental methods for studying serial thermocatalytic sensors of the pelister type with a non-selective platinum-palladium catalyst in laboratory conditions, evaluation and generalization of research results.. Results. The studies conducted made it possible to assess the impact of hydrogen sulfide, nitrogen dioxide, and sulfur dioxide on the operation of thermocatalytic sensors in explosion hazard monitoring systems at man-made facilities. It was found that high concentrations of nitrogen dioxide do not cause zero drift or changes in the sensitivity of the gas analyzer. The effect of high concentrations of sulfur dioxide also does not lead to zero drift of gas analyzers, but a decrease in sensitivity is observed in almost all thermocatalytic sensors, which confirms the need for automatic diagnostics of this indicator.. Scientific novelty. Experimental studies have made it possible to assess in detail the effect of sulfur and nitrogen dioxides, as well as hydrogen sulfide, on the performance of thermocatalytic sensors equipped with metal-ceramic gas diffusion filters, which are the main elements of explosion hazard control systems. The experiments showed that even with prolonged and repeated exposure to sulfur and nitrogen dioxides, the parameters of thermocatalytic sensors remain virtually unchanged after returning to normal operating conditions. This indicates the resistance of the sensors to the effects of these gases without significant changes in their technical characteristics. In the presence of hydrogen sulfide in the environment, the sensitivity of the studied thermocatalytic sensors is significantly reduced. In addition, after the supply of hydrogen sulfide is stopped, the parameters of the thermocatalytic sensors are restored over a fairly long period of time.. Practical value. It consists in determining the conditions under which it is necessary to carry out timely inspection, calibration, and adjustment of devices for monitoring explosive gas concentrations that operate on the thermocatalytic principle. Particular attention should be paid to the operation of such measuring devices in conditions where emissions from thermal power plants burning coal with a high sulfur content and emissions from metallurgical enterprises enter the atmosphere. The results obtained can be used to improve maintenance regulations, increase measurement accuracy, and ensure the reliability of early warning systems for explosive situations.. Keywords: hazard, combustible gases, sulfur dioxide, hydrogen sulfide, fuel mixtures, monitoring systems, sensors, explosion protection.