Ko-Kung Chen

Ko-Kung Chen

Auto-generated profile, based on publicly available information

Ko-Kung Chen

Department of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
KCK.-K. Chen
K.-K. Chen
WGWan-Yuo Guo
Wan-Yuo Guo
Huai-Che YangHuai-Che Yang
Huai-Che Yang
CLC.-J. Lin
C.-J. Lin
CWC.-H.F. Wu
C.-H.F. Wu
WCWen-Yuh Chung
Wen-Yuh Chung
BACKGROUND AND PURPOSE: Time-resolved 3D-DSA (4D-DSA) enables viewing vasculature from any desired angle and time frame. We investigated whether these advantages may facilitate treatment planning and the feasibility of using 4D-DSA as a single imaging technique in AVM/dural arteriovenous fistula radiosurgery. MATERIALS AND METHODS: Twenty consecutive patients (8 dural arteriovenous fistulas and 12 AVMs; 13 men and 7 women; mean age, 45 years; range, 18–64 years) who were scheduled for gamma knife radiosurgery were recruited (November 2014 to October 2015). An optimal volume of reconstructed time-resolved 3D volumes that defines the AVM nidus/dural arteriovenous fistula was sliced into 2D-CT-like images. The original radiosurgery treatment plan was overlaid retrospectively. The registration errors of stereotactic 4D-DSA were compared with those of integrated stereotactic imaging. AVM/dural arteriovenous fistula volumes were contoured, and disjoint and conjoint components were identified. The Wilcoxon signed rank test and the Wilcoxon rank sum test were adopted to evaluate registration errors and contoured volumes of stereotactic 4D-DSA and integration of stereotactic MR imaging and stereotactic 2D-DSA. RESULTS: Sixteen of 20 patients were successfully registered in Advanced Leksell GammaPlan Program. The registration error of stereotactic 4D-DSA was smaller than that of integrated stereotactic imaging (P = .0009). The contoured AVM volume of 4D-DSA was smaller than that contoured on the integration of MR imaging and 2D-DSA, while major inconsistencies existed in cases of dural arteriovenous fistula (P = .042 and 0.039, respectively, for measurements conducted by 2 authors). CONCLUSIONS: Implementation of stereotactic 4D-DSA data for gamma knife radiosurgery for brain AVM/dural arteriovenous fistula is feasible. The ability of 4D-DSA to demonstrate vascular morphology and hemodynamics in 4 dimensions potentially reduces the target volumes of irradiation in vascular radiosurgery.

2 February 2022 in Journal Of Neuroradiology
Verified
Journal Article
Closed access
CLChung-Jung Lin
Chung-Jung Lin
KCKo-Kung Chen
Ko-Kung Chen
YHYong-Sin Hu
Yong-Sin Hu
Huai-Che YangHuai-Che Yang
Huai-Che Yang
FCFeng-Chi Chang
Feng-Chi Chang

12 September 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
KCKo-Kung Chen
Ko-Kung Chen
CLChung-Jung Lin
Chung-Jung Lin
WCWei-Fa Chu
Wei-Fa Chu
Heterogeneous medium enhanced angiograms are key diagnostic tools in clinical practice; the associated hemodynamic information is crucial for diagnosing cardiovascular diseases. However, the dynamics of such medium in physiological blood flow are poorly understood. Herein, we report a previously unnoticed dispersion pattern, which is a universal phenomenon, of a medium in pulsatile blood flow. We present a physical theory for studying the dispersion of a steadily injected heterogeneous medium into a thin tubular blood vessel in which the blood flow is pulsatile. In a thin tubular blood vessel, we demonstrate that variations of concentration associated with the heterogeneous medium obey a one-dimensional advection diffusion equation, and the diffusion has limited effect whenever a short vascular segment is considered. A distinct feature of the distribution of the medium in the axial distance–time plane is a “dilation-retraction” pattern. The time evolution signals at different axial positions exhibit distinct concentration waveforms. A numerical scheme is proposed for exploiting this information to estimate the pulsatile velocity. Artificial data are adopted to validate the scheme. Real X-ray angiography is also analyzed to support our theory and method. The theory is applicable whenever imaging protocols involve a heterogeneous medium in pulsatile flow.