School of Electrical Engineering and Automation Wuhan University Wuhan China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2019 in IEEE Access
Verified
Journal Article
Open access
YDYongqing Deng
Yongqing Deng
JRJiangjun Ruan
Jiangjun Ruan
YQYu Quan
Yu Quan
RGRuohan Gong
Ruohan Gong
DHDaochun Huang
Daochun Huang
YXYiming Xie
Yiming Xie
This paper proposed a prediction method to predict a 10 kV oil-immersed transformer hot spot temperature. A set of feature temperature points on the transformer iron shell is proposed based on fluid-thermal field calculation. These feature points as well as transformer load rate are taken as the input parameters of a machine learning model established by support vector regression (SVR), thus to describe their relationships with the hot spot temperature. This model is trained by 9 samples selected by L9(34) orthogonal array and applied to predict the hot spot temperature of 20 test samples. The training samples are all obtained by simulation, and the test samples are consisted of simulation and transformer temperature rise test results. With effective parameter optimization of the SVR model, the predicted results agree well with the experimental and simulation data, the mean absolute percentage error (MAPE) is 1.55 %, and the maximum temperature difference is less than 3 °C. The results validated the validity and the generalization performance of the prediction model.

19 March 2020 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
JRJiangjun Ruan
Jiangjun Ruan
YDYongqing Deng
Yongqing Deng
DHDaochun Huang
Daochun Huang
CDCihan Duan
Cihan Duan
RGRuohan Gong
Ruohan Gong
QRQingyu Rong
Qingyu Rong
Transformer winding hot‐spot temperature (HST) is one of the important factors affecting transformer oil–paper insulation deterioration. This study presents a three‐dimensional coupled electromagnetic‐fluid‐thermal analysis method for HST calculation in a 10 kV oil‐immersed distribution transformer, the influence of the transformer internal metal structure parts on the HST of the winding is considered in the simulation. Combining electromagnetic‐field calculation with no‐load test and load test of the transformer provides a more accurate method to determine internal losses of the transformer. Taking those power losses as heat sources, the transformer fluid‐thermal field analysis is conducted with the finite volume method. The variation of physical parameters of transformer oil with temperature is considered in the simulation. On the basis of the equivalent thermal resistance theory, the equivalent thermal conductivities of transformer windings are obtained. The simulation results deduced from the proposed method agree well with the experimental ones, which are obtained with fibre optic temperature sensors during the transformer temperature rise test, the maximum temperature difference is <3°C. The results validated the validity and accuracy of the proposed transformer HST calculation method.

5 January 2021 in IEEE Access
Verified
Journal Article
Open access
JRJiangjun Ruan
Jiangjun Ruan
YDYongqing Deng
Yongqing Deng
YQYu Quan
Yu Quan
RGRuohan Gong
Ruohan Gong
This paper proposes an inversion method to estimate a 10 kV oil-immersed transformer transient hot spot temperature (HST). A set of transient feature quantities which can reflect the load change are proposed, those quantities as well as the real time load rate and feature temperature points on the transformer iron shell are taken as the input parameters of a machine learning model established by support vector regression (SVR), thus to describe their relationships with the transformer transient HST. K-fold cross-validation training method and grid search (GS) parameters optimization method are used to find the optimal parameters of the SVR model, the HST inversion results agree well with the transformer temperature rise test data which are conducted with short circuit method, and the HST inversion results outperform the results obtained with GA-BPNN method. The mean absolute percentage error (MAPE) is 1.66 %, and the maximum temperature difference is 2.93 °C.

24 August 2022 in IET Electric Power Applications
Verified
Journal Article
Open access
YDYongqing Deng
Yongqing Deng
JRJiangjun Ruan
Jiangjun Ruan
XDXuzhu Dong
Xuzhu Dong
DHDaochun Huang
Daochun Huang
CZChen Zhang
Chen Zhang
Transformer overheating faults have an important impact on the transformer safe and stable operation. Taking 10 kV oil‐immersed transformer as the research object, using the indirect coupling analysis method of electromagnetic thermal fluid multi‐physical field, the transformer heating characteristics under overheating faults, such as winding inter‐turn short circuit and core multi‐point grounding, are analysed, and the transformer abnormal heating state identification method is proposed based on the inversion of transformer top oil temperature rise. By inverting the transformer normal top oil temperature rise under different load rates and comparing it with the actual measured value, taking into account the top oil temperature rise inversion error, it is determined that when the top oil temperature rise measured value is higher than the inversion value by 2.9 K, it indicates the transformer is in an abnormal heating state, and the higher the deviation degree is, the deeper the degree of abnormal heating fault. The accuracy of the transformer abnormal heating state identification method is verified by the multi‐working condition temperature rise test, which can provide a certain reference for the detection and maintenance of transformer abnormal internal heating faults.

30 December 2022 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
JRJiangjun Ruan
Jiangjun Ruan
XWXuezong Wang
Xuezong Wang
TZTaotao Zhou
Taotao Zhou
XPXuelin Peng
Xuelin Peng
YDYongqing Deng
Yongqing Deng
QYQiuyu Yang
Qiuyu Yang
The trip mechanism is a weakness in circuit breakers. Traditional fault identification based on the coil current is difficult to report early mechanical defects such as coil‐plunger jam. Here, the vibration signal during the trip process was extracted. Based on the coil current signal and vibration signal, the characteristics of the trip mechanism are analyzed. The phase space reconstruction (PSR) method is used to extract features from the vibration signal. Combined with the features from the coil current waveform, the feature set representing the health condition of the trip mechanism is proposed. The fault simulation tests are carried out and the variation of current vibration characteristics under fault conditions is studied. The fault identification model based on a support vector machine (SVM) is proposed and compared with the identification results when features are extracted from a single signal. When the power supply voltage is dispersed, the prediction accuracy of fault identification is 83.3% considering only the features of the current waveform or vibration signal. And the identification accuracy rises to 96.7% while using the feature set of current and vibration signals. On basis of the current signal, the method further combines the vibration signal so that the robustness of defect identification improves.

5 June 2023 in High Voltage
Verified
Journal Article
Open access
CZChen Zhang
Chen Zhang
XDXuzhu Dong
Xuzhu Dong
JRJiangjun Ruan
Jiangjun Ruan
YDYongqing Deng
Yongqing Deng
In this article, the dynamic thermal rating assessment method of oil‐immersed power transformer with multiple operating conditions is proposed, considering the constraints of hot spot temperature (HST), top oil temperature, losses of life and the maximum allowable current of on‐load tap changer (OLTC) or bushing, which can determine the dynamic load curves under different operating conditions and give the most sensitive constraints to limit the dynamic load capacity. To improve the accuracy of HST estimation, the temperature estimation model is also improved and the thermal parameters are optimised using the HST measured by optical fibre. Finally, several application examples are studied for transformers in different scenarios. The results show that the normal cyclic dynamic transformer rating (DTR) is mainly limited by the losses of life when the ambient temperature is high, and the average load factor can be increased to 0.82 with a maximum load capacity of 1.23. The main limiting factor of short‐term DTR is the OLTC or bushing current constraint, and the average load factor can be increased to 1.00. The maximum load capacity of the transformer under both operating conditions is 23% and 50% higher than its rated load capacity, indicating that the transformer still has a large load potential available.