1 May 2017 in Tribology International
17 June 2013 in Measurement Science and Technology
1 January 2017 in Mechanical Systems and Signal Processing
2 June 2017 in Measurement Science and Technology
Detecting wear debris and measuring the increasing number of wear debris in lubrication oil can indicate abnormal machine wear well ahead of machine failure, and thus are indispensable for online machine health monitoring. A portable wear debris sensor with ferrite cores for online monitoring is presented. The sensor detects wear debris by measuring the inductance change of two planar coils wound around a pair of ferrite cores that make the magnetic flux denser and more uniform in the sensing channel, thereby improving the sensitivity of the sensor. Static testing results showed this wear debris sensor is capable of detecting 11 µ m and 50 µ m ferrous debris in 1 mm and 7 mm diameter fluidic pipes, respectively; such a high sensitivity has not been achieved before. Furthermore, a synchronized sampling method was also applied to reduce the data size and realize real-time data processing. Dynamic testing results demonstrated that the sensor is capable of detecting wear debris in real time with a high throughput of 750 ml min −1 ; the measured debris concentration is in good agreement with the actual concentration.
24 December 2014 in IEEE Transactions on Biomedical Engineering
Goal: The objective of this paper is to demonstrate a multiplexed inductive force sensor for simultaneously measuring normal force and shear forces on a foot. Methods: The sensor measures the normal force and shear forces by monitoring the inductance changes of three planar sensing coils. Resonance frequency division multiplexing was applied to signals from the multiple sensing coils, making it feasible to simultaneously measure the three forces (normal force, shear forces in x- and y-axis) on a foot using only one set of measurement electronics with high sensitivity and resolution. Results: The testing results of the prototype sensor have shown that the sensor is capable of measuring normal force ranging from 0 to 800 N and shear forces ranging from 0 to 130 N in real time. Conclusion: With its high resolution, high sensitivity, and the capability of monitoring forces at different positions of a foot simultaneously, this sensor can be potentially used for real-time measurement of plantar normal force and shear forces distribution on diabetes patient's foot. Significance: Real-time monitoring of the normal force and shear forces on diabetes patient's foot can provide useful information for physicians and diabetes patients to take actions in preventing foot ulceration.
6 July 2013 in Tribology Letters