19 May 2016 in Physical Review Letters
We present a study of laser-driven ion acceleration with micrometer and submicrometer thick plastic targets. Using laser pulses with high temporal contrast and an intensity of the order of we observe proton beams with cutoff energies in excess of 85 MeV and particle numbers of in an energy bin of 1 MeV around this maximum. We show that applying the target normal sheath acceleration mechanism with submicrometer thick targets is a very robust way to achieve such high ion energies and particle fluxes. Our results are backed with 2D particle in cell simulations furthermore predicting cutoff energies above 200 MeV for acceleration based on relativistic transparency. This predicted regime can be probed after a few technically feasible adjustments of the laser and target parameters.
20 November 2013 in Applied Physics B
We report on the development of a preamplifier module for temporal contrast enhancement and control at petawatt-class lasers. The module is based on an ultrafast optical parametric amplifier (uOPA), which produces temporally clean pulses at the 60 μJ level for seeding a chirped pulse amplification (CPA) system, namely the petawatt facility PHELIX. The amplifier module allows for gain reduction in the following amplifiers, resulting in an attenuation of amplified spontaneous emission (ASE) by more than 4 orders of magnitude. Since the ASE of a CPA system linearly depends on the seeding energy, we were able to demonstrate a continuous variation of the temporal contrast by tuning the gain of the uOPA.
18 November 2014 in Optics Express
We used time-resolved shadowgraphy to characterize the pre-plasma formation in solid-target interaction experiments with micrometer-scale accuracy. We performed quantitative measurements of the plasma density for amplified spontaneous emission (ASE) levels ranging from 2·10−7 to 10−10 backed with 2-dimensional hydrodynamic simulations. We find that ASE levels above 10−9 are able to create a significant pre-plasma plume that features a plasma canal driving a self-focusing of the laser beam. For ASE levels of 10−10, no ASE pre-plasma could be detected.
12 December 2016 in High Power Laser Science and Engineering
Using the example of the PHELIX high-energy short pulse laser we discuss the technical preconditions to investigate ion acceleration with submicrometer thick targets. We show how the temporal contrast of this system was improved to prevent pre-ionization of such targets on the nanosecond timescale. Furthermore the influence of typical fluctuations or uncertainties of the on-target intensity on ion acceleration experiments is discussed. We report how these uncertainties were reduced by improving the assessment and control of the on-shot intensity and by optimizing the positioning of the target into the focal plane. Finally we report on experimental results showing maximum proton energies in excess of 85 MeV for ion acceleration via the target normal sheath acceleration mechanism using target thicknesses on the order of one micrometer.