18 April 2014 in Journal of Biomechanical Engineering
The purpose of this paper is to design a microfluidic apparatus capable of providing controlled flow conditions suitable for red blood cell (RBC) aggregation analysis. The linear velocity engendered from the controlled flow provides constant shear rates used to qualitatively analyze RBC aggregates. The design of the apparatus is based on numerical and experimental work. The numerical work consists of 3D numerical simulations performed using a research computational fluid dynamics (CFD) solver, Nek5000, while the experiments are conducted using a microparticle image velocimetry system. A Newtonian model is tested numerically and experimentally, then blood is tested experimentally under several conditions (hematocrit, shear rate, and fluid suspension) to be compared to the simulation results. We find that using a velocity ratio of 4 between the two Newtonian fluids, the layer corresponding to blood expands to fill 35% of the channel thickness where the constant shear rate is achieved. For blood experiments, the velocity profile in the blood layer is approximately linear, resulting in the desired controlled conditions for the study of RBC aggregation under several flow scenarios.
14 August 2025 in Aerosol Science and Technology
15 January 2025 in Journal of Occupational and Environmental Hygiene
Particle filtration efficiency (PFE) is a critical property of face masks, with the most common test methods using sodium chloride as a challenge aerosol. In the absence of bottom-up uncertainty budgets for PFE, interlaboratory comparisons provide an alternative route to robustly quantify the precision and bias of the method. This work presents the results of several interlaboratory comparisons of particle filtration efficiency performed across a network of laboratories. Using log-penetration as a surrogate for PFE, it is shown that expanded reproducibility intervals were consistent across most samples, at around 26% of the nominal value of log-penetration. Between-laboratory contributions to this reproducibility were significant, nearly doubling the lab-reported uncertainties in most instances and emphasizing the need for ongoing interlaboratory studies to be performed for particle filtration. More work is required to identify the causes of these between-laboratory differences, requiring dedicated testing. Alongside uncertainty quantification, testing materials across a range of variables (such as the number of layers, amount of charge on the material, and basis weight) affirm that constant quality is a good approximation when layering or changing the basis weight on an otherwise identical material.
3 November 2025 in Aerosol Science and Technology