Rym Mehri

Rym Mehri

Auto-generated profile, based on publicly available information

Rym Mehri

Metrology Research Centre, National Research Council Canada

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RMRym Mehri
Rym Mehri
CMCatherine Mavriplis
Catherine Mavriplis
MFMarianne Fenech
Marianne Fenech
Red blood cells (RBCs) are the most abundant cells in human blood. Remarkably RBCs deform and bridge together to form aggregates under very low shear rates. The theory and mechanics behind aggregation are, however, not yet completely understood. The main objective of this work is to quantify and characterize RBC aggregates in order to enhance the current understanding of the non-Newtonian behaviour of blood in microcirculation. Suspensions of human blood were flowed and observed in vitro in poly-di-methyl-siloxane (PDMS) microchannels to characterize RBC aggregates. These microchannels were fabricated using standard photolithography methods. Experiments were performed using a micro particle image velocimetry (μPIV) system for shear rate measurements, coupled with a high-speed camera for flow visualization. RBC aggregate sizes were quantified in controlled and measurable shear rate environments for 5, 10 and 15% hematocrit. Aggregate sizes were determined using image processing techniques, while apparent viscosity was measured using optical viscometry. For the samples suspended at 5% H, aggregate size was not strongly correlated with shear rate. For the 10% H suspensions, in contrast, lowering the shear rate below 10 s-1 resulted in a significant increase of RBC aggregate sizes. The viscosity was found to increase with decreasing shear rate and increasing hematocrit, exemplifying the established non-Newtonian shear-thinning behaviour of blood. Increase in aggregation size did not translate into a linear increase of the blood viscosity. Temperature was shown to affect blood viscosity as expected, however, no correlation for aggregate size with temperature was observed. Non-Newtonian parameters associated with power law and Carreau models were determined by fitting the experimental data and can be used towards the simple modeling of blood’s non-Newtonian behaviour in microcirculation. This work establishes a relationship between RBC aggregate sizes and corresponding shear rates and one between RBC aggregate sizes and apparent blood viscosity at body and room temperatures, in a microfluidic environment for low hematocrit. Effects of hematocrit, shear rate, viscosity and temperature on RBC aggregate sizes have been quantified.

18 April 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
RMR. Mehri
R. Mehri
CMC. Mavriplis
C. Mavriplis
MFM. Fenech
M. Fenech
The purpose of this paper is to design a microfluidic apparatus capable of providing controlled flow conditions suitable for red blood cell (RBC) aggregation analysis. The linear velocity engendered from the controlled flow provides constant shear rates used to qualitatively analyze RBC aggregates. The design of the apparatus is based on numerical and experimental work. The numerical work consists of 3D numerical simulations performed using a research computational fluid dynamics (CFD) solver, Nek5000, while the experiments are conducted using a microparticle image velocimetry system. A Newtonian model is tested numerically and experimentally, then blood is tested experimentally under several conditions (hematocrit, shear rate, and fluid suspension) to be compared to the simulation results. We find that using a velocity ratio of 4 between the two Newtonian fluids, the layer corresponding to blood expands to fill 35% of the channel thickness where the constant shear rate is achieved. For blood experiments, the velocity profile in the blood layer is approximately linear, resulting in the desired controlled conditions for the study of RBC aggregation under several flow scenarios.

14 August 2025 in Aerosol Science and Technology
Verified
Journal Article
Closed access
NSNishan Sapkota
Nishan Sapkota
RMRym Mehri
Rym Mehri
JCJoel Corbin
Joel Corbin
SRSteven N. Rogak
Steven N. Rogak
TSTimothy A. Sipkens
Timothy A. Sipkens

15 January 2025 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
TSTimothy A. Sipkens
Timothy A. Sipkens
RMRym Mehri
Rym Mehri
RCRuth Perez Calderon
Ruth Perez Calderon
RGRichard G. Green
Richard G. Green
AOAndrew Oldershaw
Andrew Oldershaw
GSGregory J. Smallwood
Gregory J. Smallwood
Particle filtration efficiency (PFE) is a critical property of face masks, with the most common test methods using sodium chloride as a challenge aerosol. In the absence of bottom-up uncertainty budgets for PFE, interlaboratory comparisons provide an alternative route to robustly quantify the precision and bias of the method. This work presents the results of several interlaboratory comparisons of particle filtration efficiency performed across a network of laboratories. Using log-penetration as a surrogate for PFE, it is shown that expanded reproducibility intervals were consistent across most samples, at around 26% of the nominal value of log-penetration. Between-laboratory contributions to this reproducibility were significant, nearly doubling the lab-reported uncertainties in most instances and emphasizing the need for ongoing interlaboratory studies to be performed for particle filtration. More work is required to identify the causes of these between-laboratory differences, requiring dedicated testing. Alongside uncertainty quantification, testing materials across a range of variables (such as the number of layers, amount of charge on the material, and basis weight) affirm that constant quality is a good approximation when layering or changing the basis weight on an otherwise identical material.

8 July 2012
Verified
Conference Paper
Closed access
PDF file
RMR. Mehri
R. Mehri
CMC. Mavriplis
C. Mavriplis
MFM. Fenech
M. Fenech
The purpose of the work presented this paper is to design a model to study experimentally and numerically a micro-Couette blood flow to obtain a constant and controlled shear rate that is a suitable environment for analysis of Red Blood Cell (RBC) aggregation. Due to the simplicity of the flow conditions, aggregate size can be related to the constant shear rate applied. This Couette flow is created by the motion of a second fluid that entrains the blood. The experimental work is coupled with 3D numerical simulations performed using a research computational fluid dynamics solver, Nek5000, based on the spectral element method, while the experiments are conducted using a micro-particle image velocimetry system. Two models of microchannels, with different dimensions, 150 × 33μm and 170 × 64μm, are fabricated in the laboratory using standard photolithography methods. The design of the channel is based on several parameters determined by the simulations. A Newtonian model is tested numerically and experimentally. Blood is then tested experimentally to be compared to the simulation results. We find that using a velocity ratio of 4 between the two Newtonian fluids, we create a flow where one third of the channel thickness is filled with the fluid destined to be blood. In the blood experiments, the velocity profile in this layer is approximately linear, resulting in the desired controlled conditions for the study of RBC aggregation.