Hasan Onur Keles

Hasan Onur Keles

Auto-generated profile, based on publicly available information

Hasan Onur Keles

Department of Psychiatry

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2009 in Tissue Engineering Part C: Methods
Verified
Journal Article
Closed access
SMSangJun Moon
SangJun Moon
SHSyed K. Hasan
Syed K. Hasan
YSYoung S. Song
Young S. Song
FXFeng Xu
Feng Xu
HKHasan Onur Keles
Hasan Onur Keles
UDUtkan Demirci
Utkan Demirci
The ability to bioengineer three-dimensional (3D) tissues is a potentially powerful approach to treat diverse diseases such as cancer, loss of tissue function, or organ failure. Traditional tissue engineering methods, however, face challenges in fabricating 3D tissue constructs that resemble the native tissue microvasculature and microarchitectures. We have developed a bioprinter that can be used to print 3D patches of smooth muscle cells (5 mm × 5 mm × 81 μm) encapsulated within collagen. Current inkjet printing systems suffer from loss of cell viability and clogging. To overcome these limitations, we developed a system that uses mechanical valves to print high viscosity hydrogel precursors containing cells. The bioprinting platform that we developed enables (i) printing of multilayered 3D cell-laden hydrogel structures (16.2 μm thick per layer) with controlled spatial resolution (proximal axis: 18.0 ± 7.0 μm and distal axis: 0.5 ± 4.9 μm), (ii) high-throughput droplet generation (1 s per layer, 160 droplets/s), (iii) cell seeding uniformity (26 ± 2 cells/mm 2 at 1 million cells/mL, 122 ± 20 cells/mm 2 at 5 million cells/mL, and 216 ± 38 cells/mm 2 at 10 million cells/mL), and (iv) long-term viability in culture (>90%, 14 days). This platform to print 3D tissue constructs may be beneficial for regenerative medicine applications by enabling the fabrication of printed replacement tissues.

10 August 2011 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
FXFeng Xu
Feng Xu
CWChung‐An Max Wu
Chung‐An Max Wu
VRVenkatakrishnan Rengarajan
Venkatakrishnan Rengarajan
TFThomas Dylan Finley
Thomas Dylan Finley
HKHasan Onur Keles
Hasan Onur Keles
UDUtkan Demirci
Utkan Demirci

5 January 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ABAlessio Paolo Buccino
Alessio Paolo Buccino
HKHasan Onur Keles
Hasan Onur Keles
AOAhmet OMURTAG
Ahmet OMURTAG
Non-invasive Brain-Computer Interfaces (BCI) have demonstrated great promise for neuroprosthetics and assistive devices. Here we aim to investigate methods to combine Electroencephalography (EEG) and functional Near-Infrared Spectroscopy (fNIRS) in an asynchronous Sensory Motor rhythm (SMR)-based BCI. We attempted to classify 4 different executed movements, namely, Right-Arm—Left-Arm—Right-Hand—Left-Hand tasks. Previous studies demonstrated the benefit of EEG-fNIRS combination. However, since normally fNIRS hemodynamic response shows a long delay, we investigated new features, involving slope indicators, in order to immediately detect changes in the signals. Moreover, Common Spatial Patterns (CSPs) have been applied to both EEG and fNIRS signals. 15 healthy subjects took part in the experiments and since 25 trials per class were available, CSPs have been regularized with information from the entire population of participants and optimized using genetic algorithms. The different features have been compared in terms of performance and the dynamic accuracy over trials shows that the introduced methods diminish the fNIRS delay in the detection of changes.

1 July 2009 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SMSangJun Moon
SangJun Moon
HKHasan Onur Keles
Hasan Onur Keles
Aydogan OzcanAydogan Ozcan
Aydogan Ozcan
Ali  KhademhosseiniAli Khademhosseini
Ali Khademhosseini
EHEdward Hæggstrom
Edward Hæggstrom
UDUtkan Demirci
Utkan Demirci

16 June 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
XZXiaohui Zhang
Xiaohui Zhang
IKImran Khimji
Imran Khimji
Umut Atakan GurkanUmut Atakan Gurkan
Umut Atakan Gurkan
HSHooman Safaee
Hooman Safaee
PCPaolo Nicolas Catalano
Paolo Nicolas Catalano
UDUtkan Demirci
Utkan Demirci
5.3 million American couples of reproductive age (9%) are affected by infertility, among which male factors account for up to 50% of cases, which necessitates the identification of parameters defining sperm quality, including sperm count and motility. In vitrofertilization (IVF) with or without intra cytoplasmic sperm injection (ICSI) has become the most widely used assisted reproductive technology (ART) in modern clinical practice to overcome male infertility challenges. One of the obstacles of IVF and ICSI lies in identifying and isolating the most motile and presumably healthiest sperm from semen samples that have low sperm counts (oligozoospermia) and/or low sperm motility (oligospermaesthenia). Microfluidic systems have shown potential to sort sperm with flow systems. However, the small field of view (FOV) of conventional microscopes commonly used to image sperm motion presents challenges in tracking a large number of sperm cells simultaneously. To address this challenge, we have integrated a lensless charge-coupled device (CCD) with a microfluidic chip to enable wide FOV and automatic recording as the sperm move inside a microfluidic channel. The integrated system enables the sorting and tracking of a population of sperm that have been placed in a microfluidic channel. This channel can be monitored in both horizontal and vertical configuration similar to a swim-up column method used clinically. Sperm motilities can be quantified by tracing the shadow paths for individual sperm. Moreover, as the sperm are sorted by swimming from the inlet towards the outlet of a microfluidic channel, motile sperm that reach the outlet can be extracted from the channel at the end of the process. This technology can lead to methods to evaluate each sperm individually in terms of motility response in a wide field of view, which could prove especially useful, when working with oligozoospermic or oligospermaesthenic samples, in which the most motile sperm need to be isolated from a pool of small number of sperm.

30 September 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MAMohamad A. Alyassin
Mohamad A. Alyassin
SMSangJun Moon
SangJun Moon
HKHasan O. Keles
Hasan O. Keles
FMFahim Manzur
Fahim Manzur
RLRichard L. Lin
Richard L. Lin
UDUtkan Demirci
Utkan Demirci
Lab-chip device analysis often requires high throughput quantification of fluorescent cell images, obtained under different conditions of fluorescent intensity, illumination, focal depth, and optical magnification. Many laboratories still use manual counting - a tedious, expensive process prone to inter-observer variability. The manual counting process can be automated for fast and precise data gathering and reduced manual bias. We present a method to segment and count cells in microfluidic chips that are labeled with a single stain, or multiple stains, using image analysis techniques in Matlab and discuss its advantages over manual counting. Microfluidic based cell capturing devices for HIV monitoring were used to validate our method. Captured CD4+ CD3+T lymphocytes were stained with DAPI, AF488-anti CD4, and AF647-anti CD3 for cell identification. Altogether 4788 (76 × 3 × 21) gray color images were obtained from devices using discarded 10 HIV infected patient whole blood samples (21 devices). We observed that the automatic method performs similarly to manual counting for a small number of cells. However, automated counting is more accurate and more than 100 times faster than manual counting for multiple-color stained cells, especially when large numbers of cells need to be quantified (>500 cells). The algorithm is fully automatic for subsequent microscope images that cover the full device area. It accounts for problems that generally occur in fluorescent lab-chip cell images such as: uneven background, overlapping cell images and cell detection with multiple stains. This method can be used in laboratories to save time and effort, and to increase cell counting accuracy of lab-chip devices for various applications, such as circulating tumor cell detection, cell detection in biosensors, and HIV monitoring devices, i.e. CD4 counts.