T. K. Shajahan

T. K. Shajahan

Auto-generated profile, based on publicly available information

T. K. Shajahan

National Institute of Technology Karnataka Surathkal

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2009 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TST. K. Shajahan
T. K. Shajahan
ANAlok Ranjan Nayak
Alok Ranjan Nayak
RPRahul Pandit
Rahul Pandit
Regular electrical activation waves in cardiac tissue lead to the rhythmic contraction and expansion of the heart that ensures blood supply to the whole body. Irregularities in the propagation of these activation waves can result in cardiac arrhythmias, like ventricular tachycardia (VT) and ventricular fibrillation (VF), which are major causes of death in the industrialised world. Indeed there is growing consensus that spiral or scroll waves of electrical activation in cardiac tissue are associated with VT, whereas, when these waves break to yield spiral- or scroll-wave turbulence, VT develops into life-threatening VF: in the absence of medical intervention, this makes the heart incapable of pumping blood and a patient dies in roughly two-and-a-half minutes after the initiation of VF. Thus studies of spiral- and scroll-wave dynamics in cardiac tissue pose important challenges for in vivo and in vitro experimental studies and for in silico numerical studies of mathematical models for cardiac tissue. A major goal here is to develop low-amplitude defibrillation schemes for the elimination of VT and VF, especially in the presence of inhomogeneities that occur commonly in cardiac tissue. We present a detailed and systematic study of spiral- and scroll-wave turbulence and spatiotemporal chaos in four mathematical models for cardiac tissue, namely, the Panfilov, Luo-Rudy phase 1 (LRI), reduced Priebe-Beuckelmann (RPB) models, and the model of ten Tusscher, Noble, Noble, and Panfilov (TNNP). In particular, we use extensive numerical simulations to elucidate the interaction of spiral and scroll waves in these models with conduction and ionic inhomogeneities; we also examine the suppression of spiral- and scroll-wave turbulence by low-amplitude control pulses. Our central qualitative result is that, in all these models, the dynamics of such spiral waves depends very sensitively on such inhomogeneities. We also study two types of control schemes that have been suggested for the control of spiral turbulence, via low amplitude current pulses, in such mathematical models for cardiac tissue; our investigations here are designed to examine the efficacy of such control schemes in the presence of inhomogeneities. We find that a local pulsing scheme does not suppress spiral turbulence in the presence of inhomogeneities; but a scheme that uses control pulses on a spatially extended mesh is more successful in the elimination of spiral turbulence. We discuss the theoretical and experimental implications of our study that have a direct bearing on defibrillation, the control of life-threatening cardiac arrhythmias such as ventricular fibrillation.

4 September 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ANAlok Ranjan Nayak
Alok Ranjan Nayak
TST. K. Shajahan
T. K. Shajahan
Alexander PanfilovAlexander Panfilov
Alexander Panfilov
RPRahul Pandit
Rahul Pandit
Cardiac fibroblasts, when coupled functionally with myocytes, can modulate the electrophysiological properties of cardiac tissue. We present systematic numerical studies of such modulation of electrophysiological properties in mathematical models for (a) single myocyte-fibroblast (MF) units and (b) two-dimensional (2D) arrays of such units; our models build on earlier ones and allow for zero-, one-, and two-sided MF couplings. Our studies of MF units elucidate the dependence of the action-potential (AP) morphology on parameters such as , the fibroblast resting-membrane potential, the fibroblast conductance , and the MF gap-junctional coupling . Furthermore, we find that our MF composite can show autorhythmic and oscillatory behaviors in addition to an excitable response. Our 2D studies use (a) both homogeneous and inhomogeneous distributions of fibroblasts, (b) various ranges for parameters such as , and , and (c) intercellular couplings that can be zero-sided, one-sided, and two-sided connections of fibroblasts with myocytes. We show, in particular, that the plane-wave conduction velocity decreases as a function of , for zero-sided and one-sided couplings; however, for two-sided coupling, decreases initially and then increases as a function of , and, eventually, we observe that conduction failure occurs for low values of . In our homogeneous studies, we find that the rotation speed and stability of a spiral wave can be controlled either by controlling or . Our studies with fibroblast inhomogeneities show that a spiral wave can get anchored to a local fibroblast inhomogeneity. We also study the efficacy of a low-amplitude control scheme, which has been suggested for the control of spiral-wave turbulence in mathematical models for cardiac tissue, in our MF model both with and without heterogeneities.

31 January 2007 in Physical Review E
Verified
Journal Article
Closed access
PDF file
TST. K. Shajahan
T. K. Shajahan
SSSitabhra Sinha
Sitabhra Sinha
RPRahul Pandit
Rahul Pandit
Every sixth death in industrialized countries occurs because of cardiac arrhythmias such as ventricular tachycardia (VT) and ventricular fibrillation (VF). There is growing consensus that VT is associated with an unbroken spiral wave of electrical activation on cardiac tissue but VF with broken waves, spiral turbulence, spatiotemporal chaos and rapid, irregular activation. Thus spiral-wave activity in cardiac tissue has been studied extensively. Nevertheless, many aspects of such spiral dynamics remain elusive because of the intrinsically high-dimensional nature of the cardiac-dynamical system. In particular, the role of tissue heterogeneities in the stability of cardiac spiral waves is still being investigated. Experiments with conduction inhomogeneities in cardiac tissue yield a variety of results: some suggest that conduction inhomogeneities can eliminate VF partially or completely, leading to VT or quiescence, but others show that VF is unaffected by obstacles. We propose theoretically that this variety of results is a natural manifestation of a complex, fractal-like boundary that must separate the basins of the attractors associated, respectively, with spiral breakup and single spiral wave. We substantiate this with extensive numerical studies of Panfilov and Luo-Rudy I models, where we show that the suppression of spiral breakup depends sensitively on the position, size, and nature of the inhomogeneity.

1 April 2016 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
TST K Shajahan
T K Shajahan
SBSebastian Berg
Sebastian Berg
SLStefan Luther
Stefan Luther
VKValentin Krinski
Valentin Krinski
PBPhilip Bittihn
Philip Bittihn
Spiral waves in cardiac tissue can pin to tissue heterogeneities and form stable pinned waves. These waves can be unpinned by electric stimuli applied close to the pinning center during the vulnerable window of the spiral. Using a phase transition curve (PTC), we quantify the response of a pinned wave in a cardiac monolayer to secondary excitations generated electric field pulses. The PTC can be used to construct a one-dimensional map that faithfully predicts the pinned wave's response to periodic field stimuli. Based on this 1D map, we predict that pacing at a frequency greater than the spiral frequency, over drive pacing, leads to phase locking of the spiral to the stimulus, which hinders unpinning. In contrast, under drive pacing can lead to scanning of the phase window of the spiral, which facilitates unpinning. The predicted mechanisms of phase scanning and phase locking are experimentally tested and confirmed in the same monolayers that were used to obtain the PTC. Our results have the potential to help choose optimal parameters for low energy antifibrillation pacing schemes.

27 August 2012 in Chaos: An Interdisciplinary Journal of Nonlinear Science
Verified
Journal Article
Closed access
BBBartłomiej Borek
Bartłomiej Borek
TST. K. Shajahan
T. K. Shajahan
JGJames K. Gabriels
James K. Gabriels
AHAlex Hodge
Alex Hodge
LGLeon Glass
Leon Glass
ASAlvin Shrier
Alvin Shrier
Pacemaker interactions can lead to complex wave dynamics seen in certain types of cardiac arrhythmias. We use experimental and mathematical models of pacemakers in heterogeneous excitable media to investigate how pacemaker interactions can be a mechanism for wave break and reentrant wave dynamics. Embryonic chick ventricular cells are cultured invitro so as to create a dominant central pacemaker site that entrains other pacemakers in the medium. Exposure of those cultures to a potassium channel blocker, E-4031, leads to emergence of peripheral pacemakers that compete with each other and with the central pacemaker. Waves emitted by faster pacemakers break up over the slower pacemaker to form reentrant waves. Similar dynamics are observed in a modified FitzHugh-Nagumo model of heterogeneous excitable media with two distinct sites of pacemaking. These findings elucidate a mechanism of pacemaker-induced reentry in excitable media.

21 September 2020 in Physical Review E
Verified
Journal Article
Closed access
PDF file
SPShreyas Punacha
Shreyas Punacha
NANaveena Kumara A.
Naveena Kumara A.
TST. K. Shajahan
T. K. Shajahan
Spiral waves of excitation are common in many physical, chemical, and biological systems. In physiological systems like the heart, such waves can lead to cardiac arrhythmias and need to be eliminated. Spiral waves anchor to heterogeneities in the excitable medium, and to eliminate them they need to be unpinned first. Several groups focused on developing strategies to unpin such pinned waves using electric shocks, pulsed electric fields, and recently, circularly polarized electric fields (CPEF). It was shown that in many situations, CPEF is more efficient at unpinning the wave compared to other existing methods. Here, we study how the circularly polarized field acts on the pinned spiral waves and unpins it. We show that the termination always happens within the first rotation of the electric field. For a given obstacle size, there exists a threshold time period of the CPEF below which the spiral can always be terminated. Our analytical formulation accurately predicts this threshold and explains the absence of the traditional unpinning window with the CPEF. We hope our theoretical work will stimulate further experimental studies about CPEF and low energy methods to eliminate spiral waves.