Birger Kollmeier

Birger Kollmeier

Auto-generated profile, based on publicly available information

Birger Kollmeier

Medizinische Physik, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2015 in International Journal of Audiology
Verified
Journal Article
Closed access
PDF file
MAMichael Akeroyd
Michael Akeroyd
SAStig Arlinger
Stig Arlinger
RBRuth A. Bentler
Ruth A. Bentler
ABArthur Boothroyd
Arthur Boothroyd
NDNorbert Dillier
Norbert Dillier
BKBirger Kollmeier
Birger Kollmeier
Objective: To provide guidelines for the development of two types of closed-set speech-perception tests that can be applied and interpreted in the same way across languages. The guidelines cover the digit triplet and the matrix sentence tests that are most commonly used to test speech recognition in noise. They were developed by a working group on Multilingual Speech Tests of the International Collegium of Rehabilitative Audiology (ICRA). Design: The recommendations are based on reviews of existing evaluations of the digit triplet and matrix tests as well as on the research experience of members of the ICRA Working Group. They represent the results of a consensus process. Results: The resulting recommendations deal with: Test design and word selection; Talker characteristics; Audio recording and stimulus preparation; Masking noise; Test administration; and Test validation. Conclusions: By following these guidelines for the development of any new test of this kind, clinicians and researchers working in any language will be able to perform tests whose results can be compared and combined in cross-language studies.

13 December 2016 in International Journal of Audiology
Verified
Journal Article
Closed access
BKBirger Kollmeier
Birger Kollmeier
JKJürgen Kiessling
Jürgen Kiessling
A review about technical and perceptual factors in hearing aid technology, research and development is provided, covering current commercial solutions, underlying models of hearing loss for usage in hearing devices and emerging future technical solutions for hearing aid functionalities. A chain of techniques has provided incremental, but steady increases in user benefit, e.g. in the fields of hearing aid amplification, feedback suppression, dynamic compression, noise reduction and situation adaptation. The models describing the perceptual consequences of sensorineural hearing impairment describe the effects on the acoustical level, the neurosensory level and the cognitive level and provide the framework for compensatory (or even substitutional) functions of hearing aids in terms of the attenuation component, the distortion component and the neural component of the hearing loss. A major factor is the requirement of a strong individualisation of hearing aid solutions calling for an appropriate assessment of the different sensorineural components of a hearing loss, especially with respect to bilateral and binaural hearing aid solutions.

1 January 2013 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
Anna WarzybokAnna Warzybok
Anna Warzybok
JRJan Rennies
Jan Rennies
TBThomas Brand
Thomas Brand
SDSimon Doclo
Simon Doclo
BKBirger Kollmeier
Birger Kollmeier
In order to study the interaction between the intelligibility advantage in rooms due to the presence of early reflections and due to binaural unmasking, a series of speech reception threshold experiments was performed employing a single reflection of the frontal target speech source as a function of its delay ranging from 0 to 200 ms. The direction of the reflection and the spatial characteristic of the interfering noise (diotic, diffuse, or laterally localized) were varied in the experiments. For the frontal reflection, full temporal integration was observed for all three noise types up to a delay of at least 25 ms followed by gradual intelligibility decay at longer delays. At 200 ms delay the reflection introduced additional intelligibility deterioration. For short delays, intelligibility was not reduced when the reflection was spatially separated from the direct sound in the diffuse and lateral noise conditions. A release from the deterioration effect at 200 ms delay was found for all spatially separated reflections. The suppression of a detrimental reflection was symmetrical in diffuse noise, but azimuth-dependent in lateral noise. This indicates an interaction of spatial and temporal processing of speech reflections which challenges existing binaural speech intelligibility models.

4 September 2018 in International Journal of Audiology
Verified
Journal Article
Closed access
HHHongmei Hu
Hongmei Hu
XXXin Xi
Xin Xi
LWLena L N Wong
Lena L N Wong
SHSabine Hochmuth
Sabine Hochmuth
Anna WarzybokAnna Warzybok
Anna Warzybok
BKBirger Kollmeier
Birger Kollmeier
Objective: Development of the Mandarin Chinese matrix (CMNmatrix) sentence test for speech intelligibility measurements in noise according to the international standard procedure. Design: A 50-word base matrix representing the distribution of phonemes and lexical tones of spoken Mandarin was established. Hundred sentences capturing all the co-articulations of two consecutive words were recorded. Word-specific speech recognition functions, speech reception thresholds (SRT: signal-to-noise ratio (SNR), that provides 50% speech intelligibility) and slopes were obtained from measurements at fixed SNRs. The speech material was homogenised in intelligibility by applying level corrections up to ± 2 dB. Subsequently, the CMNmatrix test was evaluated, the comparability of test lists was measured at two fixed SNRs. To investigate the training effect and establish the reference data, speech recognition was measured adaptively. Study sample: Overall, the study sample contained 80 normal-hearing native Mandarin-speaking listeners. Results: Multi-centre evaluation measurements confirmed that test lists are equivalent in intelligibility, with a mean SRT of −10.1 ± 0.1 dB SNR and a slope of 13.1 ± 0.9 %/dB. The reference SRT is −9.3 ± 0.8 and −11.2 ± 1.2 dB SNR for the open- and closed-set response format, respectively. Conclusion: The CMNmatrix test is suitable for accurate and internationally comparable speech recognition measurements in noise.

28 July 2009 in IEEE Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Closed access
GGGiso Grimm
Giso Grimm
VHVolker Hohmann
Volker Hohmann
BKBirger Kollmeier
Birger Kollmeier
The effect of a binaural coherence-based noise reduction scheme on the feedback stability margin and sound quality in hearing aids has been analyzed. For comparison, a conventional adaptive feedback canceler (AFC) and the combination of the adaptive filter with the binaural coherence filter have been tested. The observed quantities are feedback stability and target signal attenuation. An objective measure of feedback stability, i.e., the added stable gain (ASG) was obtained for a number of algorithmic settings and compared to a subjective measure of feedback stability, the added tolerable gain (ATG). In an attempt to eliminate the subjective bias in estimating the ATG, the ldquounbiased added gainrdquo (UAG) is introduced as a new method. Both, objective and subjective measures give similar results for feedback stability. This allows for a valid comparison across different feedback reduction schemes both in isolation and in combination: whereas the ASG of the coherence filter without combination with AFC is negligible, the results indicate that a robust feedback suppression in hearing aids can be achieved if the benefit of de-correlation and the head-shadow effect in binaural hearing aids is used in an advantageous way. The ASG reaches 23 dB for the best combination at the expense of an average target signal attenuation of 15 dB at critical frequencies. The attribute of the coherence filter is that it adaptively limits the maximum gain before feedback becomes audible. The UAG analysis revealed that subjects used a stable quality criterion across the conditions tested and that the group of subjects covered a large range of individual quality criteria.

24 October 2018 in IEEE/ACM Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Closed access
FXFeifei Xiong
Feifei Xiong
SGStefan Goetze
Stefan Goetze
BKBirger Kollmeier
Birger Kollmeier
BMBernd T. Meyer
Bernd T. Meyer
The reverberation time (RT) and the early-to-late reverberation ratio (ELR) are two key parameters commonly used to characterize acoustic room environments. In contrast to conventional blind estimation methods that process the two parameters separately, we propose a model for joint estimation to predict the RT and the ELR simultaneously from single-channel speech signals from either fullband or subband frequency data, which is referred to as joint ROom Parameter Estimator (jROPE). An artificial neural network is employed to learn the mapping from acoustic observations to the RT and the ELR classes. Auditory-inspired acoustic features obtained by temporal modulation filtering of the speech time-frequency representations are used as input to the neural network. Based on an in-depth analysis of the dependency between the RT and the ELR, a two-dimensional (RT, ELR) distribution with constrained boundaries is derived, which is then exploited to evaluate four different configurations for jROPE. Experimental results show that - in comparison to the single-task ROPE system which individually estimates the RT or the ELR - jROPE provides improved results for both tasks in various reverberant and (diffuse) noisy environments. Among four proposed joint types, the one incorporating multi-task learning with shared input and hidden layers yields the best estimation accuracies on average. When encountering extreme reverberant conditions with RTs and ELRs lying beyond the derived (RT, ELR) distribution, the type considering RT and ELR as a joint parameter performs robust in particular. From state-of-the-art algorithms that were tested in the Acoustic Characterization of Environments (ACE) challenge, jROPE achieves comparable results among the best for all individual tasks (RT and ELR estimation from fullband and subband signals).