1 June 2022 in International Journal of Nanomedicine
Background: Airspace Dimensions Assessment with nanoparticles (AiDA) is a new method for non-invasive measurement of pulmonary distal airspaces. The aim of this study was to compare AiDA measurements with other pulmonary function variables to better understand the potential of AiDA in a clinical context. Methods: AiDA measurements and pulmonary function tests were performed in 695 subjects as part of the Swedish CArdioPulmonary bioImage Study. The measurement protocol included spirometry, measurement of diffusing capacity of carbon monoxide, oscillometry and pulmonary computed tomography. AiDA indices were compared to all other pulmonary examination measurements using multivariate statistical analysis. Results: Our results show that AiDA measurements were significantly correlated with other pulmonary function examination indices, although covariance was low. We found that AiDA variables explained variance in the data that other lung function variables only influenced to a minor extent. Conclusion: We conclude that the AiDA method provides information about the lung that is inaccessible with more conventional lung function techniques.
14 April 2023 in Respiratory Medicine
Welders are exposed to gas and particle emissions that can cause severe lung disease, such as chronic obstructive pulmonary disease (COPD), a leading cause of mortality and morbidity worldwide. It is difficult to detect COPD early and therefore mitigating measures may be delayed. The aim of this study was to investigate lung health in welders and evaluate new sensitive methods with potential to assess early onset pulmonary changes in occupational settings. This study assessed the lung health and symptoms in active welders (n = 28) and controls (n = 17). Lung measurements were performed with standard spirometry and new methods: airspace dimension assessment (AiDA), oscillometry, blood serum biomarkers (club cell secretory protein 16, surfactant protein D, matrix metalloproteinases, fibroblast, hepatocyte growth factor, interleukins), and one urine biomarker (desmosine). According to spirometry measurements, all participants had normal lung function. However, prevalence of cough was significantly higher among welders compared with controls and lung changes were found in welders with the novel methods. Welders had significantly higher respiratory system resistance assessed with oscillometry, serum levels of metalloproteinases 9 and hepatocyte growth factor, compared with controls. Airspace dimensions were on average higher among welders compared with controls, but the difference was not significant. The number of welding years correlated with decreased respiratory system reactance and increased serum levels of matrix metalloproteinases 9, interleukin 6, and hepatocyte growth factor. Airspace dimension assessment indices were correlated with increasing levels of inflammatory markers and matrix metalloproteinases. This study indicated the potential to use new and more sensitive methods for identification of changes in lungs when standard spirometry failed to do so.
2 March 2023 in ERJ Open Research
Introduction: Firefighters have increased risk of chronic respiratory disease. Standard clinical techniques used in medical checkups may not detect the earliest microstructural changes in peripheral airways. A new technique called Airspace Dimension Assessment (AiDA) has been shown to enable early detection of emphysema in COPD. This method may be useful in the occupational setting to detect early pulmonary changes and enable prevention. The aim of the present study was to evaluate whether AiDA detects changes in the most peripheral airways of firefighters.Methods: AiDA, measuring the effective airspace radius (rAiDA) and zero-second recovery (R0), was used as a complement to other standardised lung function measures in 21 male firefighters and 16 age-matched male controls.Results: There were significant differences inrAiDAandR0between firefighters (mean±sdrAiDA0.301±0.024 mm; mean±sdR00.336±0.116 arbitrary units) and controls (mean±sdrAiDA0.276±0.044 mm; mean±sdR00.5760.168 arbitrary units), p=0.03 and p<0.001, respectively. Higher forced vital capacity was found in firefighters (mean 101% of predicted) than in controls (mean 93% of predicted; p=0.03). No significant differences were found with regard to either the ratio between forced expiratory volume in 1 s and forced vital capacity or forced expiratory volume in 1 s. The majority of firefighters had diffusing capacity of the lung for carbon monoxide, oscillometry and single-breath nitrogen washout values within the normal ranges.Conclusion: AiDA parameters can provide information on early pulmonary peripheral changes that may not be seen with standard techniques used in screening of pulmonary function.
23 February 2025 in medRxiv
Bicuspid aortic valve (BAV), a prevalent congenital cardiac defect, predisposes patients to severe complications. Despite its high heritability, previously identified protein-coding and common regulatory mutations account for only a small fraction of cases. To address this gap, we investigated the role of rare regulatory mutations. By integrating high-resolution three-dimensional genome organization profiling with whole-genome sequencing, we analyzed sixteen patients with BAV and normal tricuspid aortic valves. Our findings reveal a 1.5-fold enrichment of gain-of-function regulatory mutations in previously implicated genes among BAV patients. Genome-wide, moderately rare mutations (allele frequencies below 3%) were predicted to alter the transcriptome of specific developmental valve mesenchymal cell and fibroblast populations. Expanding the BAV pathway network with newly implicated genes uncovered substantial genetic heterogeneity underlying the disease. These results position rare regulatory mutations as pivotal contributors to missing BAV heritability and emphasize the need for further research of their mechanistic roles.
9 September 2023 in European Respiratory Journal
Preterm birth often results in respiratory complications, sometimes including the diagnosis bronchopulmonary dysplasia (BPD). These infants are thought to have fewer and larger alveoli than their term peers. It is still unclear to what degree this persists later in life. We used the new aerosol-based method Airspace Dimension Assessment (AiDA) to evaluate the size of the distal airspaces for adolescents that were born preterm with and without a diagnosis of BPD. We investigated 41 adolescents between 15-17 years of age: 17 preterm with BPD, 8 preterm without BPD and 16 term born controls. We used AiDA to measure distal airspace radius (rAiDA) in the lungs by inhaled aerosols. In addition, lung function was evaluated by spirometry, impulse oscillometry and diffusing capacity of carbon monoxide (DLCO). The average airspace radius, rAiDA, was 313±54 µm for the BPD group, 257±23 µm non-BPD preterm group, and 231±12 µm for the controls (p<0.001). Early gestational age was strongly associated with enlarged distal airspace radii (p<0.001). The preterm group had normal lung function, apart from a decreased forced expiratory volume in the first second (FEV1, p<0.05) and DLCO (p<0.05). According to the AiDA measurements, the adolescents born preterm had larger distal airspaces than their term peers. The link between lower gestational age and increased airspaces may potentially be due to an earlier arrest in lung development.