1 May 2018 in Review of Scientific Instruments
We report on the design and characterization of a modular γ-ray detector assembly developed for accurate and efficient detection of coincident 511 keV back-to-back γ-rays following electron-positron annihilation. Each modular detector consists of 16 narrow lutetium yttrium oxyorthosilicate scintillators coupled to a multi-anode Hamamatsu H12700B photomultiplier tube. We discuss the operation and optimization of 511 keV γ-ray detection resulting from testing various scintillators and detector arrangements concluding with an estimate of the coincident 511 keV detection efficiency for the intended experiment and a preliminary test representing one-quarter of the completed array.
25 June 2022 in The European Physical Journal D
The quest for making a triplet positronium (Ps) Bose–Einstein condensate confined in a micron-sized cavity in a material such as porous silica faces at least three interrelated problems: (1) About $$10^7$$ spin polarized Ps atoms must be injected into a small cavity within a porous solid material without vaporizing it. (2) It is known that Ps atoms confined in 30–100 nm diameter cavities in porous silica do not remain in the gas phase, but become stuck to the cavity walls at room temperature (Cooper et al., Phys. Rev. B 97:205302, 2018). (3) Cooling a gas of Ps atoms to cryogenic temperatures by energy exchange with the walls would be a very slow process (Saito and Hyodo, in: Surko, Gianturco (eds) New Directions in Antimatter Chemistry and Physics, Springer Dordrecht, Netherlands, 2001) because of the relatively low collision rate with the walls and the large mismatch between the masses of the Ps and the wall atoms. A possible solution of these difficulties is presented, based on cooling the implanted positrons in an isotopically pure diamond single crystal target, subsequent saturating of the wall Ps coverage so that a substantial portion of the Ps will be in the gaseous state, and thermalizing the gas-phase Ps via collisions with the low effective mass wall Ps. A design process for the target material is outlined as well, including preliminary results in porous cavity fabrication using focused ion beam milling. Graphical
9 June 2023 in Physical Review A
We have discovered that 5 keV bursts of positrons with an initial longitudinal spin polarization of , when implanted into a thin Ni(100) crystal, are emitted with 20% efficiency at thermal energies from its surface with polarization. We conclude that the positron spin polarization is preserved while interacting with the Ni, despite the 0.61 T average transverse magnetization of the Ni at room temperature. The resulting polarized beam has been focused to a 0.025-mm mean-diameter spot when accelerated to 5 keV and will be uniquely suited for experiments on a neutral spin aligned plasma, spin- and angle-resolved positronium emission spectroscopy, and critical for producing a triplet positronium Bose-Einstein condensate.
1 January 2022 in Review of Scientific Instruments
We describe here the development and characterization of a position-sensitive detector for Rydberg atom experiments. The detector builds on an earlier design that field-ionized incident Rydberg positronium (Ps) atoms and then electrostatically focused the freed positrons onto a micro-channel plate (MCP) detector without the use of a position sensitive anode. In this design, pulses from the MCP are deposited onto a resistive anode, providing a means of measuring the incident particles’ x, y positions. The first detector constructed utilized a pair of MCPs in a chevron configuration and was used to observe the focusing of Rydberg Ps atoms from an electrostatic mirror. A second detector, developed for use in a measurement of the 1S–2S interval of Ps, incorporates three MCPs in a Z-stack configuration to produce larger pulses. Using a UV-induced signal, we have characterized the performance of the assembled detectors, finding a spatial resolution of mm for the largest induced pulses and for pulse widths of ∼7–10 ns FWHM; pulse times can be resolved to better than 1 ns. The Ps induced signal is anticipated to yield pulses times larger, which are expected to achieve a spatial resolution of mm. Appropriate lenses could make possible applications involving either imaging a large area or magnifying a small area of the incident Ps spatial distribution.
12 August 2025 in Journal of Applied Physics
A model is presented for analyzing positron–electron annihilation spectra obtained using single shot positron annihilation lifetime spectroscopy. The model is tested against data resulting from 1×106 positrons in a single few ns burst impinging on a sample such that the positronium annihilation decay components are accurately reported in a single shot. The model may prove useful in the detection and characterization of nanoscale defects at either the instant of a supplied stimuli or following an extended period of irradiation.
29 August 2022 in The European Physical Journal D