Takeshi Komoda

Takeshi Komoda

Auto-generated profile, based on publicly available information

Takeshi Komoda

Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum Berlin, Berlin, Germany

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
TKTakeshi Komoda
Takeshi Komoda
AFAlexander Frumkin
Alexander Frumkin
CKChristoph Knosalla
Christoph Knosalla
RHRoland Hetzer
Roland Hetzer

4 September 2012 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
TKTakeshi Komoda
Takeshi Komoda
TDThorsten Drews
Thorsten Drews
RHRoland Hetzer
Roland Hetzer
HLHans B. Lehmkuhl
Hans B. Lehmkuhl
Even though left ventricular assist devices (LVADs) may fit into the bodies of small adult patients, their prognosis is worse than that of larger patients. We investigated the relationship between lethal complications and the body surface area (BSA) in patients who received an LVAD. Our study included 167 patients who received a BerlinHeart INCOR LVAD in our centre. The median BSA was 2.00 m2 (range: 1.56–2.47 m²). From the line graph showing the relationship between the BSA for the cut-off point and the P-value of the log-rank test for the Kaplan–Meier probability of freedom from events, the definitive cut-off point was determined on the basis that, with a decrease in the BSA below this value, the P-value gradually increases. For freedom from death due to stroke or systemic bleeding, a definitive cut-off point existed and this was a BSA of 1.867 m2. For freedom from death due to sepsis, no definitive cut-off point was found. The multivariate Cox analysis revealed that a BSA of <1.867 m2 was an independent risk factor for death due to stroke or systemic bleeding (hazard ratio: 2.665, 95% confidence interval: 1.349–5.265, P = 0.0048). One-year freedom from death due to stroke or systemic bleeding during the VAD support was 49.1% in patients with a BSA of <1.867 m2 (n = 42) and 82.7% in those with a BSA of ≥1.867 m2 (n = 125; P = 0.0033). The lower BSA is an independent risk factor for mortality due to stroke or systemic bleeding during the VAD support.

1 August 2008 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
TKTakeshi Komoda
Takeshi Komoda
RHRoland Hetzer
Roland Hetzer
HLHans B. Lehmkuhl
Hans B. Lehmkuhl
Objective: We analyzed the prognosis of candidates for heart transplantation (HTx) after being listed with ‘urgent status’ for donor heart allocation

3 June 2008 in Circulation
Verified
Journal Article
Closed access
MRMattias Roser
Mattias Roser
AHAshraf Hamdan
Ashraf Hamdan
TKTakeshi Komoda
Takeshi Komoda
CKCharalampos Kriatselis
Charalampos Kriatselis
PSPhilipp Stawowy
Philipp Stawowy
IPIngo Paetsch
Ingo Paetsch

20 June 2007 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
TKTakeshi Komoda
Takeshi Komoda
YWYuguo Weng
Yuguo Weng
CNChisato Nojiri
Chisato Nojiri
RHRoland Hetzer
Roland Hetzer

31 October 2008 in The Journal of Heart and Lung Transplantation
Verified
Journal Article
Closed access
PDF file
TKTakeshi Komoda
Takeshi Komoda
RHRoland Hetzer
Roland Hetzer
HLHans B. Lehmkuhl
Hans B. Lehmkuhl