28 January 2025 in IEEE Transactions on Instrumentation and Measurement
Thrust is one of the key parameters that determines the performance of thrusters in the propulsion systems of microsatellites. Thrusters are widely used in space exploration, quantum communication and other fields. At present, the study on thrust measurement under low load has made great progress, meeting the requirements of high precision. However, it is still challenging to achieve high precision under heavy load. In this paper, a flexible inverted pendulum based on multiple elliptic flexure hinges is proposed to achieve high accuracy thrust measurement under heavy load. The theoretical model between sensitivity, stability and pendulum parameters under heavy load is established. The principle that the pendulum can balance heavy load and high accuracy is explained as well. The pendulum is calibrated using precision machined electro-static combs. The performance of the pendulum was evaluated by a cold gas thruster and a Hall thruster. Experimental results show that the resolution of the pendulum is better than 0.3 μN and the measurement range covers 0.3-1300 μN for loads up to 4 kg.
10 February 2025 in IEEE Sensors Journal
Thrust stands serve as essential devices for assessing the performance of micro-thrusters, demanding strictly calibration prior to application. However, it is challenging to generate traceable standard force with large range and high accuracy. Therefore, we design an electrostatic cylinder using a cylindrical capacitor array. The accuracy and traceability of the force are ensured by capacitance gradient. In this method, the coefficient measurement and force generation of electrostatic cylinder are both carried out on the thrust stand, thus eliminating the deviation caused by electrode posture changes. The capacitance gradient and electrostatic force are explored under different overlap depths and axial deviations. Validation and application experiments are carried out. Experiments show that electrostatic cylinder can produce a force of 0-1836.12 μN. It is reliable and accurate to take capacitance gradient as the coefficient of electrostatic force and voltage. The stiffness of pendulum is calibrated by electrostatic cylinder. The result shows that the stiffness of pendulum is 165.35 N/m and the relative uncertainty is 1.77%. The electrostatic cylinder is suitable for the calibration of various thrust stand, and is of great significance for the development of standard force generation devices.
28 May 2025 in IEEE Transactions on Instrumentation and Measurement
In the field of gravitational wave detection, micro thrusters are used to compensate for environmental disturbances. The resolution of the thrust stand typically needs to meet micronewton specifications with sufficiently low background noise. Presently, significant progress has been made in research concerning thrust resolution. However, it remains an ongoing challenge to measure thrust precisely while maintaining low noise levels. In this paper, a novel parallelogram mechanism thrust stand (PMTS) is proposed, leveraging its insensitivity to non-thrust direction moments to achieve precise thrust measurements with low noise. The theoretical model for steady-state thrust and the stiffness model of the PMTS are established. The typical responses of the PMTS under different force loading conditions are tested. In addition, the thrusts of a cold gas thruster and a Hall micro thruster are tested in a high-vacuum environment. The experimental results show that the resolution of the PMTS is 80 nN, while background noise is better than 0.1 μN/Hz1/2 above 0.6 mHz.
20 August 2025 in IEEE Transactions on Instrumentation and Measurement
Micro thrusters play a crucial role in satellite orbit correction and attitude control. Given their low thrust, reducing the stiffness of the thrust stand is often required to enhance resolution. However, since the thrust typically ranges from micronewtons to several millinewtons, a thrust stand with fixed stiffness is insufficient to meet the demands. The trade-off between high resolution and wide range remains a key challenge in ground testing of thruster. Therefore, an efficient stiffness adjustment method is proposed by introducing the negative restoring moment of extension spring. Tests show that the stiffness of the stand can be continuously adjusted from 19.71 to 1.28 N/m. The models of nonlinearity and fixed-end offset of spring are established to evaluate their impact on the results. Performance validation using electrostatic force show that the thrust stand achieves a resolution better than 0.5 μN while extending the range to 3346.4 μN. The thrust of the micro-Hall thruster was tested at various flow and discharge voltages based on this thrust stand. The uncertainty evaluation of the stand shows that the expanded uncertainty is better than 2.0% when thrust is 73.55 μN. This study is significant for optimizing the resolution and range of force sensors.