1 October 1998 in Clinical Orthopaedics and Related Research
Fracture of the long bones results in a repair process that has the potential to restore the anatomic morphology and mechanical integrity of the bone without scar tissue. The repair process can occur in two patterns. In the first, under conditions of rigid stabilization, direct osteonal remodeling of the fracture line can occur with little or no external callus, a process known as direct bone repair. The second pattern of repair involves bridging of the fragments with external callus and formation of bone in the fracture site by endochondral healing. This type of repair is known as indirect bone healing and occurs under less rigid interfragmentary stabilization. The rate of healing and the extent of callus in this type of repair can be modulated by the mechanical conditions at the fracture site. Applying cyclic interfragmentary micromotion for short periods has been shown to influence the repair process significantly, and characteristics of this stimulus influence the healing response observed. In the current study, a short term interfragmentary cyclic micromovement applied at a high strain rate induced a greater amount of periosteal callus than the same stimulus applied at a low strain rate. This high strain rate stimulus applied later in the healing period significantly inhibited the progress of healing. The beneficial effect of this particular biophysic stimulus early in the healing period may be related to the viscoelastic nature of the differentiating connective tissues in the early endochondral callus. In the early endochondral callus, high rates of movement induce a greater deformation of the fracture fragments because of the stiffening of the callus. Alternatively, the transduction pathway may involve streaming potentials as a result of the high movement rate.
1 September 1996 in Clinical Orthopaedics and Related Research
A study was made of the role of the fibula in weightbearing and its contribution to ankle joint stability in 10 anatomic specimen lower limbs. On axial loading of the lower limb, the fibula was found to take an average of 17% of a 1500 N axial load. The proportion of the load carried by the fibula increased with the total loading. It also increased when the line of load was displaced laterally and when the ankle joint was in dorsiflexion and decreased when the line of loading shifted medially or the joint was plantar flexed. With loading, the lateral malleolus migrated distally relative to the medial malleolus, except after fibular osteotomy, when it migrated proximally. There was an approximately inverse relationship between proportional fibular loading and distal fibular migration. Cutting the inferior tibiofibular ligament reduced the proportional load in the fibula and increased its distal migration. The interosseous membrane modified the load distribution between the tibia and the fibula, with the distal fibula carrying a higher proportion of the axial load than did the proximal. Surgical repair of a ruptured inferior tibiofibular ligament, using either 1 or 2 screws, was associated with an abnormal pattern of load distribution and fibular displacement.
1 August 2009 in Clinical Orthopaedics and Related Research
Estioned. Viewed in mechanical terms, fracture healing represents a steady increase in strength and stiffness of a broken bone and it is only when these values are sufficiently high to support unrestricted weight bearing that a fracture can be said to be healed. Information on the rate of increase of the mechanical properties of a healing bone is therefore valuable in determining both the rate at which a fracture will heal and in helping to define an objective and measurable endpoint of healing. A number of techniques have been developed to quantify bone healing in mechanical terms and these are described and discussed in detail. Clinical studies, in which measurements of fracture stiffness have been used to identify a quantifiable end point of healing, compare different treatment methods, predictably determine whether a fracture will heal, and identify factors which most influence healing, are reviewed and discussed....
1 December 2007 in Medical Engineering & Physics
Total ankle replacement (TAR) was first attempted in the early 1970s, but poor early results lead to it being abandoned in favour of arthrodesis. Arthrodesis is not totally satisfactory, often causing further hindfoot arthritis and this has lead to a resurgence of interest in joint replacement. New designs which more closely approximated the natural anatomy of the ankle and associated biomechanics have produced more encouraging results and led to renewed interest in total ankle replacement. Three prostheses dominate the market: Agility, Buechel-Pappas and STAR, and improving clinical results with these devices have led to more designs appearing on the market. Modern designs of prosthetic ankles almost exclusively consist of three part prostheses with a mobile bearing component, similar to the Buechel-Pappas and STAR. Clinical results of these newer designs are limited and short-term and have often been carried out by the designers of the implants. This paper presents a brief history of the development of total ankle replacement and a review of the current status.
1 May 2001 in Clinical Biomechanics
1 January 1990 in Journal of Medical Engineering & Technology
Three techniques for measuring fracture healing are presented. These techniques are: (1) use of strain gauge measurements of the forces in an external fixator to determine fracture stiffness, (2) measurement of the vibration modes of a fractured long bone compared to the unfractured contralateral and (3) comparison of the ultrasound velocity across the fracture site with that for the normal unfractured bone. Examples of clinical results obtained using these techniques are presented, and the advantages and disadvantages of each technique are discussed.