Fan Zhang

Fan Zhang

Auto-generated profile, based on publicly available information

Fan Zhang

Zhongyuan University of Technology School of Energy & Environment No.1 Huaihe Road, Xinzheng City, Zhengzhou, Henan, 450007, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2023 in International Journal of Low-Carbon Technologies
Verified
Journal Article
Open access
PDF file
DZDong Zhou
Dong Zhou
ZMZhaofeng Meng
Zhaofeng Meng
YIN LIUYIN LIU
YIN LIU
SDSuiju Dong
Suiju Dong
FZFan Zhang
Fan Zhang
MWMingming Wang
Mingming Wang
In this paper, the thermal performance of three low-global warming potential refrigerants R1224yd(Z), R1223zd(E) and R1336mzz(Z) were studied to replace R245fa in the high-temperature heat pump system. The results showed that the heating capacity of R1224yd(Z), R1223zd(E) and R1336mzz(Z) was 6, 12 and 88% less than that of R245fa, respectively. The coefficient of performance (COP) of R1224yd(Z) and R1223zd(E) was 2 and 1% higher than that of R245fa, respectively. However, the COP of R1336mzz(Z) was 5% less than that of R245fa. The difference in compressor discharge temperature between R1224yd(Z), R1223zd (E), R1336mzz(Z) and R245fa was about ±5°C. R1224yd(Z) is the best refrigerant to replace R245fa. R1223zd(E) is the second. R1336mzz(Z) cannot be directly replaced unless the original system is modified.