Huong Thi Bich Tran

Huong Thi Bich Tran

Auto-generated profile, based on publicly available information

Huong Thi Bich Tran

Renal Division, Department of Medicine University of Medicine and Pharmacy Ho Chi Minh City Vietnam

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2023 in Nephrology
Verified
Journal Article
Closed access
ALAdrian Liew
Adrian Liew
ALAida Lydia
Aida Lydia
BMBien J. Matawaran
Bien J. Matawaran
PSPaweena Susantitaphong
Paweena Susantitaphong
HTHuong Thi Bich Tran
Huong Thi Bich Tran
LLLee Ling Lim
Lee Ling Lim

31 July 2024 in MedPharmRes
Verified
Journal Article
Open access
PDF file
HPHien Van Pham
Hien Van Pham
NTNhat Van Tran
Nhat Van Tran
KTKien To
Kien To
HTHuong Thi Bich Tran
Huong Thi Bich Tran
This study aimed to compare the accuracy of physical examinations (PE), hemodynamic parameters and flow access of arteriovenous fistula (AVF) on duplex Doppler ultrasound (DUS) in detecting AVF stenosis among hemodialysis patients after confirmed by DUS. A cross-sectional study was conducted on chronic hemodialysis patients at Cho Ray Hospital, Ho Chi Minh City, Viet Nam. Demographic and clinical data were collected through a questionnaire and medical records. All eligible patients were consecutively selected and underwent DUS, PE, and assessment of hemodynamic parameters. AVF stenosis was defined as ≥50% reduction in luminal diameter by DUS. Area under the curve and its 95% confidence interval were calculat-ed to measure the validity of tests. The median age of 324 eligible patients was 49 years (interquartile range [IQR] 38–61), with women comprising 54% of the sample. The median number of years on dialysis was 8 (IQR 5–13). Additionally, 49.7% of patients had a history of previous central venous catheter placements, while and 80.25% had a history of previous AVF creation. The percentage of patients with stenosis of ≥50% was 25.6%. Positive findings in pulse augmentation, arm elevation, swollen fistula arm, and collateral veins in ipsilateral arm were observed in 50.9%, 38.0%, 9.9%, and 8.0% of the sample, respectively. Pulse aug-mentation (AUC=0.96, 95%CI: 0.92–1.00) and arm elevation (AUC=0.74, 95%CI: 0.67–0.81) provided the highest AUC. Patients with positive pulse augmentation or arm elevation test should undergo DUS immediately for early detecting stenosis.

31 December 2024 in MedPharmRes
Verified
Journal Article
Open access
PDF file
HPHien Van Pham
Hien Van Pham
NTNhat Van Tran
Nhat Van Tran
KTKien To
Kien To
HTHuong Thi Bich Tran
Huong Thi Bich Tran
There is a need for studies to establish a specific access recirculation (AR) threshold for screening arteriovenous fistula (AVF) stenosis in hemodialysis patients. This study was to assess the validity of AR against duplex doppler ultrasound in detecting AVF stenosis in hemodialysis patients. This cross-sectional study recruited chronic hemodialysis patients with AVF installment of at least three months. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), Youden’s index, and area under the curve (AUC) were calculated to establish AR thresholds for the screening of AVF stenosis<50% and AVF stenosis≥50%. The sample included 324 hemodialysis patients (193 non-stenosis, 48 stenosis<50%, and 83 stenosis≥50%). Hemodialysis patients with AVF stenosis≥50% had the highest AR (10.45±14.03%). AR was not valid in screening for AVF stenosis<50%. When screening for AVF stenosis≥50%, AR threshold of ≥4% or 5% provided optimal Youden indexes. AR threshold of 4% was found a sensitivity of 72.3%, a specificity of 46.9%, PPV of 31.9%, and NPV of 83.1%. AR threshold of 5% found a sensitivity of 60.2%, a specificity of 58.9%, PPV of 33.6%, and NPV of 81.1%. Both thresholds displayed AUC of 0.60 (95%CI 0.54–0.65, p<0.01). AR of 4% should be used for screening stenosis≥50% in hemodialysis patients.