3 June 2021 in American Journal of Neuroradiology
BACKGROUND: Infarct volume inversely correlates with good recovery in stroke. The magnitude and predictors of infarct growth despite successful reperfusion via endovascular treatment are not known. PURPOSE: We aimed to summarize the extent of infarct growth in patients with acute stroke who achieved successful reperfusion (TICI 2b–3) after endovascular treatment. DATA SOURCES: We performed a systematic review and meta-analysis by searching MEDLINE and Google Scholar for articles published up to October 31, 2020. STUDY SELECTION: Studies of >10 patients reporting baseline and post-endovascular treatment infarct volumes on MR imaging were included. Only patients with TICI 2b–3 were included. We calculated infarct growth at a study level as the difference between baseline and follow-up MR imaging infarct volumes. DATA ANALYSIS: Our search yielded 345 studies, and we included 10 studies reporting on 973 patients having undergone endovascular treatment who achieved successful reperfusion. DATA SYNTHESIS: The mean baseline infarct volume was 19.5 mL, while the mean final infarct volume was 37.5 mL. A TICI 2b reperfusion grade was achieved in 24% of patients, and TICI 2c or 3 in 76%. The pooled mean infarct growth was 14.8 mL (95% CI, 7.9–21.7 mL). Meta-regression showed higher infarct growth in studies that reported higher baseline infarct volumes, higher rates of incomplete reperfusion (modified TICI 2b), and longer onset-to-reperfusion times. LIMITATIONS: Significant heterogeneity among studies was noted and might be driven by the difference in infarct growth between early- and late-treatment studies. CONCLUSIONS: These results suggest considerable infarct growth despite successful endovascular treatment reperfusion and call for a faster workflow and the need for specific therapies to limit infarct growth.
11 February 2025 in BMJ Case Reports
In this case study, we presented a challenging neurovascular intervention where a Woven EndoBridge (WEB) intrasaccular device was used to treat a 4.5 mm ruptured vertebral artery fusiform aneurysm by sacrificing the vessel with great precision. The patient had a dissection of the left vertebral artery at the posterior inferior cerebellar artery (PICA) origin. The WEB device was deployed immediately proximal to the origin of the PICA. After WEB deployment, further stasis and occlusion were achieved with coils. This combination of the WEB device and coils allowed for a precise and controlled sacrifice, ensuring continued filling of the PICA from the contralateral vertebral artery. The outcome of the procedure was successful, as the patient experienced complete vessel occlusion with no adverse effects. This case demonstrates a non-standard use of the WEB device in tandem with coils to treat a ruptured fusiform vertebral artery aneurysm.