Xue Jiang

Xue Jiang

Auto-generated profile, based on publicly available information

Xue Jiang

Interdisciplinary Research Center of Smart Sensors, Academy of Advanced Interdisciplinary Research, Xidian University, Xi'an 710071, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2020 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
XJXue Jiang
Xue Jiang
PLPeter B. Lillehoj
Peter B. Lillehoj
Rapid diagnostic tests are one of the most commonly used tests to detect and screen for infectious diseases in the developing world. While these tests are simple, inexpensive, and readily available, they rely on finger-prick blood sampling, which requires trained medical personnel, poses risks of infection, and can complicate cooperation in young children, asymptomatic individuals, and communities with blood taboos. Here, we report a novel microneedle-based skin patch for the rapid detection of protein biomarkers in dermal interstitial fluid. Sample collection is facilitated by a hydrophilic hollow microneedle array that autonomously extracts and transports interstitial fluid to an antibody-based lateral flow test strip via surface tension for colorimetric antigen detection. We employ a simple gold enhancement treatment to enhance the detection sensitivity of this colloidal gold-based lateral flow assay and elucidate the underlying mechanism of this enhancement mechanism through experimental investigation. For proof-of-concept, this device was used to detect Plasmodium falciparum histidine-rich protein 2, a biomarker for malaria infection, which could be detected at concentrations as low as 8 ng/mL. Each test can be completed in <20 min and requires no equipment. To the best of our knowledge, this work is the first demonstration of a microneedle-based lateral flow assay for rapid protein detection in dermal interstitial fluid. In addition to its simplicity, minimally invasive nature, and low cost, this diagnostic device can be readily adapted to detect other protein biomarkers in interstitial fluid, making it a promising tool for point-of-care testing.

21 December 2020 in The Analyst
Verified
Journal Article
Open access
PDF file
XJXue Jiang
Xue Jiang
PLPeter B. Lillehoj
Peter B. Lillehoj
Lateral flow immunochromatographic assays (LFIAs) are analytical devices used to detect the presence of one or more target analytes in a liquid sample. While LFIAs are one of the simplest and inexpensive types of immunoassays, they consist of multiple components (sample pad, conjugate pad, membrane, absorbent pad, backing card) and materials, requiring time-consuming device assembly. Here, we report a unique lateral flow immunochromatographic assay constructed from a single piece of cellulose paper, which is fabricated via laser cutting. Compared with conventional lateral flow immunochromatographic devices, this single-layer immunoassay enables simpler and faster fabrication, while minimizing material consumption and overall device costs. For proof-of-concept, this device was used to detect Plasmodium falciparum histidine-rich protein 2 (PfHRP2), a biomarker for malaria infection, which could be detected at concentrations as low as 4 ng mL−1 by the naked eye with no cross reactivity with other common Plasmodium protein biomarkers. While offering similar speed and ease-of-use as conventional LFIAs with a higher detection sensitivity than existing LFIAs for PfHRP2 detection, this single-layer lateral flow immunoassay has the potential to improve malaria testing, as well as the detection of other important protein biomarkers for point-of-care testing.

1 May 2022 in Chinese Chemical Letters
Verified
Journal Article
Closed access
RNRuizhi Ning
Ruizhi Ning
JFJinhai Fan
Jinhai Fan
LKLiang Kong
Liang Kong
XJXue Jiang
Xue Jiang
YQyun qian
yun qian
WWWeiwei Wu
Weiwei Wu

14 April 2020 in ACS Combinatorial Science
Verified
Journal Article
Closed access
YFYang Fan
Yang Fan
YWYanxing Wang
Yanxing Wang
XJXue Jiang
Xue Jiang
BLBi Lin
Bi Lin
RLRuichan Lv
Ruichan Lv

1 April 2017
Verified
Conference Paper
Closed access
XJXue Jiang
Xue Jiang
PLPeter B. Lillehoj
Peter B. Lillehoj
We report an innovative and simple approach for fabricating pneumatic microvalves via an assembly-free 3D printing technique. These valves are based on monolithic elastomeric valves fabricated by multilayer soft lithography but this method circumvents the need for specialized layering, alignment and bonding. 3D printed microfluidic devices containing flow channels and pneumatic valves were fabricated and tested for functionality. Using these devices, we successfully demonstrate valve actuation for precise liquid flow control and on/off operation. The speed and simplicity of this approach make it a promising technique for rapid prototyping and manufacturing of 3D printed microfluidic devices with fully integrated components.