Özlem Çakır Madenci

Özlem Çakır Madenci

Auto-generated profile, based on publicly available information

Özlem Çakır Madenci

Department of Biochemistry, Kartal Dr. Lütfi Kırdar City Hospital, İstanbul, Türkiye

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Burns
Verified
Journal Article
Closed access
ÖMÖzlem Çakır Madenci
Özlem Çakır Madenci
SYSezer Yakupoğlu
Sezer Yakupoğlu
NBNur Benzonana
Nur Benzonana
NYNihal Yücel
Nihal Yücel
DADerya Akbaba
Derya Akbaba
AKAsuman Orçun Kaptanağası
Asuman Orçun Kaptanağası

15 June 2017 in Biochemia Medica
Verified
Journal Article
Open access
PDF file
ÖMÖzlem Ç. Madenci
Özlem Ç. Madenci
AOAsuman Orçun
Asuman Orçun
ZYZeynep Yildiz
Zeynep Yildiz
RSRana Sirmali
Rana Sirmali
NTNazan Tunçbilek
Nazan Tunçbilek
ABAycan Bölük
Aycan Bölük
Evaluation of new Beckman Coulter 25(OH) Vitamin D assay and potential improvement of clinical interpretation

1 January 2016 in Biochemia Medica
Verified
Journal Article
Open access
MEMerve Kaymak Ekşioğlu
Merve Kaymak Ekşioğlu
ÖMÖzlem Çakır Madenci
Özlem Çakır Madenci
NYNihal Yücel
Nihal Yücel
AEAbdullah Elçi
Abdullah Elçi
BTBülent Turhan
Bülent Turhan
AOAsuman Orçun
Asuman Orçun
The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer(®) Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.

15 November 2018 in Turkish Journal of Gastroenterology
Verified
Journal Article
Closed access
GŞGülcan Şahin-Eryılmaz
Gülcan Şahin-Eryılmaz
KBKayhan Basak
Kayhan Basak
ÖÇÖzlem Çakır-Madenci
Özlem Çakır-Madenci
HKHacer Koç
Hacer Koç
STSabah Tuzun
Sabah Tuzun
MDMustafa Reşat Dabak
Mustafa Reşat Dabak
Background/Aims: This study aimed to evaluate the relationship between irritable bowel syndrome (IBS) and plasma and tissue ghrelin levels. Materials and Methods: Patients who had undergone gastroscopy procedure for any reason previously were enrolled in the study. Among these, patients with IBS symptoms were evaluated according to the Roma III criteria. The healthy control group comprised patients with no IBS symptom and had undergone gastroscopy procedure for another reason. The plasma ghrelin level and tissue ghrelin level obtained by immunohistochemical examination of biopsy specimens taken from the gastric antrum and corpus were evaluated in all participants. Results: The mean age of 90 participants was 43.64±12.64 years. The median value of the plasma ghrelin level was 3.29 (1.2-12.7) in the diarrhea group (IBS-D), 1.49 (0.82-7.08) in the constipation group (IBS-C), and 1.5 (0.2-3.7) in the control group. The plasma ghrelin levels between the groups were found to be significantly higher in IBS-D than in IBS-C and the control groups (p=0.001 and p=0.001, respectively). On comparing antral mucosal gland biopsy outcomes among the groups, staining intensity score was found to be significantly high in IBS-C as compared with the control group, whereas no significant difference was observed between IBS-D and the control groups (p=0.020 and p=0.429, respectively). Conclusion: The plasma ghrelin level in IBS-D and the staining intensity in the antral mucosal gland in IBS-C were found to be significantly higher. In addition, there was no difference between the groups in terms of ghrelin staining intensity in the gastric corpus. Cite this article as: Şahin-Eryılmaz G, Başak K, Çakır-Madenci Ö, et al. Relationship between irritable bowel syndrome and plasma and tissue ghrelin levels. Turk J Gastroenterol 2018; 29: 631-5.

1 May 2022 in Revista da Associação Médica Brasileira
Verified
Journal Article
Open access
MTMüjgan Kaya Tuna
Müjgan Kaya Tuna
AIArzu Cennet Işık
Arzu Cennet Işık
ÖMÖzlem Çakır Madenci
Özlem Çakır Madenci
KKKerem Sami Kaya
Kerem Sami Kaya
Obesity is one of the etiological factors of sleep disorders (e.g., obstructive sleep apnea and restless leg syndrome). The aim of this study was to determine the effect of obesity on sleep quality by using the Pittsburgh Quality İndex and Berlin Question are and evaluate the association of sleep with anthropometric and metabolic parameters. A total of 76 patients (41 females and 35 males) between the ages of 18 and 70 years with a body mass index >30 kg/m2 were included in this study. Homeostatic model assessment-insulin resistance, hemoglobin A1c, alanine aminotransferase, aspartate transaminase, total cholesterol, low-density lipoprotein, triglyceride, high-density lipoprotein, and thyroid-stimulating hormone levels were analyzed. Sleep quality was evaluated with the Pittsburgh Sleep Quality Index, Berlin Questionnaire, and the Restless Leg Syndrome Questionnaire. A significant correlation was observed between Pittsburgh sleep quality index and body mass index, neck circumference, body fat index, muscle mass, hip and waist circumference, hemoglobin A1c, and homeostatic model assessment-insulin resistance (ps<0.005). The Pittsburgh sleep quality index median (2.5-97.5 percentile) value was 8 (2-18.6) in the patient group and 3.5 (0.1-7.9) in the control group (p<0.0001). Body mass index was found to be the predictor on Pittsburgh sleep quality index (R2=0.162, F=3.726, analysis of variance p=0.008). Notably, 88% (67) and 95% (57) of the poor sleepers were found to be at high risk for obstructive sleep apnea according to Berlin Questionnaire and Pittsburgh Sleep Quality Index, respectively. Also, the frequency of restless leg syndrome was 45% in obese individuals. We observed a significant correlation between Pittsburgh sleep quality index and the anthropometric and metabolic parameters. Also, the frequency of obstructive sleep apnea and restless leg syndrome was 88% and 45%, respectively, in obese individuals.

28 December 2023 in Turkish Journal of Hematology
Verified
Journal Article
Open access
ÖMÖzlem Çakır Madenci
Özlem Çakır Madenci
ÖHÖzlem Hürmeydan
Özlem Hürmeydan
AOAsuman Orçun
Asuman Orçun
FEFatma Erdoğmuş
Fatma Erdoğmuş
The capillary zone electrophoresis (CZE) and high-performance liquid chromatography (HPLC) methods were compared in terms of HbA2 measurement for the assessment of hemoglobinopathies. CZE was compared with HPLC for the evaluation of patients without hemoglobinopathy (n=321), with β-thalassemia trait (n=113), and with common (HbD-Punjab, E, C, S/A, and S/S) and rare (HbS/D, O-Arap, Lepore, G-Coushata, Setif, Hamadan, Q-Iran, and H) variants (n=21). The reference range for HbA2 was determined by CZE. Among patients without hemoglobinopathy, the median (2.5th-97.5th percentiles) values were 97.4% (97.0-98.0%) and 97.5% (96.6-98.4%) for HbA (p=0.060) and 2.4% (1.6-3.0%) and 2.5% (1.6-3.1%) for HbA2 (p<0.001) by HPLC and CZE, respectively. The reference range for HbA2 was 1.6-3.1% by CZE. In the comparison of methods for HbA2, there was a constant error of 0.255 (confidence interval: 0.062-0.448) and bias of 0.10% (limit of agreement: 0.33-0.53), and higher values were obtained with CZE. A strong correlation was observed between the methods (r=0.782). Interrater agreement was almost perfect for clinical diagnosis (ϰ=0.911). The two methods detected and identified the common variants similarly. All rare variants, except HbH by HPLC and HbS/D by CZE, were detected as separate peaks by both methods. The two methods were in agreement regarding the preliminary identification of β-thalassemia patients. Different Hb variants were detected by both methods but with possible methodological interference for HbA2 measurements. CZE is a reliable and simple alternative for the evaluation of hemoglobinopathies. The standardization of HbA2 measurements should be prioritized as more techniques become available in routine laboratory practice.