5 May 2009 in Physical Review Letters
We carry out high-precision calculation of parity violation in a cesium atom, reducing theoretical uncertainty by a factor of 2 compared to previous evaluations. We combine previous measurements with calculations and extract the weak charge of the nucleus, . The result is in agreement with the standard model (SM) of elementary particles. This is the most accurate to-date test of the low-energy electroweak sector of the SM. In combination with the results of high-energy collider experiments, we confirm the energy dependence (or “running”) of the electroweak force over an energy range spanning 4 orders of magnitude (from to ). Additionally, our result places constraints on a variety of new physics scenarios beyond the SM. In particular, we increase the lower limit on the masses of extra bosons predicted by models of grand unification and string theories.
24 December 2014 in Physical Review Letters
The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of . Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now . Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.
29 November 2012 in Physical Review A
The Stark shift of the ytterbium (Yb) optical clock transition due to room-temperature blackbody radiation is dominated by a static Stark effect, which was recently measured to high accuracy [J. A. Sherman et al., Phys. Rev. Lett. 108, 153002 (2012)]. However, room-temperature realization of the clock at uncertainty requires a dynamic contribution to this static approximation. This dynamic term largely depends on a single electric dipole matrix element for which theoretically and experimentally derived values disagree significantly. We determine this important matrix element by two independent methods, which yield consistent values. Along with precise radiative lifetimes of and , we report the clock shift due to an ideal 300 K blackbody environment to 0.05 precision.
21 December 2011 in Physical Review A
We consider the effect of variation on the vibrational spectrum of Sr in the context of a planned experiment to test the stability of using optically trapped Sr molecules [Zelevinsky et al., Phys. Rev. Lett. 100, 043201 (2008); Kotochigova et al., Phys. Rev. A 79, 012504 (2009)]. We find the prospective experiment to be 3 to 4 times less sensitive to fractional variation in as it is to fractional variation in . Depending on the precision ultimately achieved by the experiment, this result may give justification for the neglect of variation or, alternatively, may call for its explicit consideration in the interpretation of experimental results.
29 June 2021 in Physical Review Letters
We propose a high-performance atomic clock based on the 1.81 PHz transition between the ground and first-excited state of doubly ionized lead. Utilizing an even isotope of lead, both clock states have , where , , and are the conventional quantum numbers specifying nuclear, electronic, and total angular momentum, respectively. The clock states are nondegenerate and completely immune to nonscalar perturbations, including first order Zeeman and electric quadrupole shifts. Additionally, the proposed clock is relatively insusceptible to other frequency shifts (blackbody radiation, second order Zeeman, Doppler), accommodates “magic” rf trapping, and is robust against decoherence mechanisms that can otherwise limit clock stability. By driving the transition as a two-photon process, the accompanying probe Stark shift is appreciable yet manageable for practical Rabi frequencies.
2 May 2018 in Physical Review Letters
We demonstrate the absence of a dc Stark shift in an ytterbium optical lattice clock. Stray electric fields are suppressed through the introduction of an in-vacuum Faraday shield. Still, the effectiveness of the shielding must be experimentally assessed. Such diagnostics are accomplished by applying high voltage to six electrodes, which are grounded in normal operation to form part of the Faraday shield. Our measurements place a constraint on the dc Stark shift at the level, in units of the clock frequency. Moreover, we discuss a potential source of error in strategies to precisely measure or cancel nonzero dc Stark shifts, attributed to field gradients coupled with the finite spatial extent of the lattice-trapped atoms. With this consideration, we find that Faraday shielding, complemented with experimental validation, provides both a practically appealing and effective solution to the problem of dc Stark shifts in optical lattice clocks.