1 January 2019 in Mediterranean Journal of Hematology and Infectious Diseases
Introduction Neonatal sepsis (NS) is a common systemic disease that causes morbidity and mortality in newborns. But there is no ideal biomarker that can be used in the early diagnosis of NS. In recent studies, platelet width to lymphocyte ratio (PLR) have been reported to play a critical role in the inflammatory process. In this study, we aimed to contribute to the research about whether or not PLR can be used in the early diagnosis of NS. Methods This retrospective cohort study was conducted among the newborns whose born in ?zmir Buca Maternity and Pediatric Hospital between March 2015-February 2016. During these twelve months, 611 neonates with EOS were admitted to our neonatal intensive care unit. One hundred and forty-nine neonates with suspected EOS, 67 neonates with proven EOS and 92 healty neonates were enrolled in the study. Results Platelet width lymphocyte (LPR) values of the groups were calculated 56.5 ± 17.8 vs 62.4± 14.9 vs 15.3 ± 2.1 respectively. PLR values of suspected or proven EOS group was significantly higher than the control group. PLR has AUC 0.89 to 0.93, cutoff value of 39.5 to 57.7, sensitivity of 88.9% to 91.3% and specifity of 94.7% to 97.6%, positive predictive value of 94.3% to 97.4%, and negative predictive value of 88.6% to 91.8% in suspected and proven sepsis diagnosis. Conclusion Based on our results suggest that PLR can be used as a biomarker predictive of EOS.
11 September 2019 in Fetal and Pediatric Pathology
Aims: Red cell distribution width to platelet ratio (RPR) has been reported as a useful inflammatory marker and prognostic indicator of adult inflammatory diseases. In the present study, red cell distribution width (RDW) and RPR parameters, which are parts of a complete blood count analysis, were compared to the traditional C reactive protein (CRP) and procalcitonin (PCT) parameters to investigate the potential to predict early onset sepsis (EOS) in neonates with or without positive blood cultures. Methods: An observational, retrospective cohort study was conducted to evaluate newborns born in our hospital. Results: RDW, RPR, CRP, PCT, Immature to total neutrophil ratio (I/T), and white blood cell (WBC) counts were higher in suspected and proven EOS compared to control group. Conclusion: We believe that RPR may be used in diagnosis of early onset neonatal sepsis and may be a good alternative to other tools as a readily available biomarker.
31 August 2020 in Journal of Pediatric Intensive Care
By setting out from increased neutrophil count, decreased lymphocyte count, and increased mean platelet volume (MPV), which is a result of the effect of inflammation on blood cells, we aimed to investigate whether neutrophil to lymphocyte ratio (NLP) and MPV can be used as an auxiliary parameter for the diagnosis of early-onset neonatal sepsis (EOS). This study was conducted by analyzing term neonates with EOS and physiological jaundice who were admitted to the neonatal intensive care unit of Izmir Katip Celebi University Ataturk Training and Research Hospital. A total of 63 neonate files were examined to include 30 term neonates with EOS, and 77 neonate files were examined to include 30 term neonates with physiological jaundice as a control group. NLR had an area under the curve (AUC) of 0.891 for prediction of EOS. At a cut-off level of 1.42, NLR had a likelihood ratio (LR) of 5.5, sensitivity of 88%, a specificity of 84%, a positive predictive value (PPV) of 84.6%, and a negative predictive value (NPV) of 87.5%. MPV had an AUC of 0.666 for the prediction of EOS and at a cut-off level of 9.3 fL, MPV had an LR of 1.23, sensitivity of 84%, a specificity of 32%, a PPV of 55.2%, and an NPV of 66.6%. In conclusion, this study provides evidence that NLR and MPV can be used in addition to conventional parameters in the diagnosis of EOS.
9 November 2019 in Fetal and Pediatric Pathology
Background: We investigated the predictive ability of the platelet-to-lymphocyte ratio (PLR) in preterm infants to discriminate those with and without hemodynamically significant PDA (hsPDA and non-hsPDA), hsPDA defined by those requiring medical intervention. Methods: This observational retrospective cohort study included premature neonates (<34 weeks gestational age) with routine complete blood counts in a neonatal intensive care unit. Results: PLR values on the 1st, 2nd, 3rd, and 7th days of birth were higher and lymphocyte counts were lower in the hsPDA than in the non-hsPDA group. Plateletcrit (PCT) values on the 2nd and 3rd days of birth were lower in the hsPDA group. All hsPDAs closed with medical therapy. Conclusions: PLR may be a supportive tool for predicting those preterm infants with PDAs requiring medical intervention. This may serve as a guide for future studies investigating the predictive value of PCT and PLR for hsPDA in preterm infants.
19 July 2019 in Fetal and Pediatric Pathology
Aims: We investigated the relationship between total serum bilirubin (TSB) and carboxyhemoglobin (COHb) in term neonates with detected and treated hemolysis within a particular time frame with the aim of augmenting the case for early diagnosis and prevention of morbidity in hemolysis. Materials and Methods: The study group comprised term newborns who were above the 95th percentile for TSB, underwent intravenous immunoglobulin (IVIG) or applied total exchange transfusion due to hemolysis. Newborns without hemolysis who were above the 95th TSB percentile and required phototherapy comprised the control group. Results: At a cutoff COHb value of 2.2%, 80.8% sensitivity, 95.5% specificity, 18.1 likelihood ratio, positive predictive value of 94.7%, and negative predictive value of 83.2% were identified. Conclusion: We found that COHb is a sensitive and specific method for detecting hemolysis, and it can be used in the early diagnosis of hemolytic diseases causing early and severe hyperbilirubinemia.
26 April 2019 in Pediatric Drugs