Demet Altun

Demet Altun

Auto-generated profile, based on publicly available information

Demet Altun

Istanbul Faculty of Medicine, Department of Anesthesiology Istanbul University Istanbul Turkey

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2017 in Pediatric Anesthesia
Verified
Journal Article
Closed access
PDF file
DADemet Altun
Demet Altun
MSMukadder Orhan Sungur
Mukadder Orhan Sungur
AAAchmet Ali
Achmet Ali
TÖTülay Özkan-Seyhan
Tülay Özkan-Seyhan
NSNükhet Sivrikoz
Nükhet Sivrikoz
EÇEmre Çamcı
Emre Çamcı

1 January 2013 in Pediatric Neurosurgery
Verified
Journal Article
Closed access
PDF file
AAAchmet Ali
Achmet Ali
BBBurcu Basaran
Burcu Basaran
MYMesut Yornuk
Mesut Yornuk
DADemet Altun
Demet Altun
AAAydin Aydoseli
Aydin Aydoseli
IAI. Ozkan Akinci
I. Ozkan Akinci
Background: Craniosynostosis is a condition resulting from the premature fusion of cranial sutures. Corrective surgery is often associated with a large amount of blood loss, with transfusion of red blood cells (RBC) and fresh frozen plasma (FFP). The aims of this study were to determine the variables associated with increased blood loss and postoperative complications. Methods: A retrospective analysis was performed of 42 pediatric patients who underwent craniosynostosis surgery. We analyzed the following: demographic parameters, duration of surgery, intraoperative blood loss, RBC, FFP and fluid transfusion, urine output, and hemodynamic parameters. In addition, we recorded the postoperative length of stay in the intensive care unit and hospital, postoperative blood loss and early complications. Results: The mean age, weight and surgical duration were 9.2 ± 3.2 months, 9.3 ± 2.0 kg and 255.8 ± 46.7 min, respectively. Intraoperative blood loss was 61.2 ± 15.3 ml/kg and RBC, FFP and fluid transfusion were 27.3 ± 7.1 ml/kg, 16.5 ± 4.7 ml/kg and 21.7 ± 4.6 ml/kg/h, respectively. Greater intraoperative blood loss was associated with longer surgical duration (p = 0.001, correlation coefficient = 0.495, R2 = 0.245) and lower patient weight (p < 0.001, correlation coefficient = -0.557, R2 = 0.311). Longer hospital stay was associated with greater intraoperative blood loss (p < 0.001, correlation coefficient = 0.754, R2 = 0.568) and greater intraoperative RBC transfusion (p < 0.001, correlation coefficient = 0.795, R2 = 0.632). Conclusion: Severe blood loss occurred in all children who underwent craniosynostotic corrections. Furthermore, the duration of surgery, patient weight and certain surgical procedures correlated with greater blood loss. Careful hemodynamic monitoring and evaluation of a patient's hematocrit value and volume status together may be helpful in maintaining the balance between insufficient and excessive blood product transfusion.

24 October 2018 in Turkish Journal of Anesthesia and Reanimation
Verified
Journal Article
Closed access
DADemet Altun
Demet Altun
AAAchmet Ali
Achmet Ali
ECEmre Camci
Emre Camci
AOAnil Ozonur
Anil Ozonur
TSTulay Ozkan Seyhan
Tulay Ozkan Seyhan
In this prospective randomized study, we aimed to evaluate the effect of tracheal intubation with four different laryngoscopes [Macintosh direct laryngoscope-classic laryngoscope (CL), McCoy (MC), C-Mac video-laryngoscope (CM) and McGrath video-laryngoscope (MG)] on haemodynamic responses in patients with a normal airway. One hundred and sixty patients were included. Succeeding haemodynamic measurements were performed immediately after intubation (T2) and for 5 min with 1-min intervals (T3-T4-T5-T6-T7). The primary outcome was the heart rate (HR) and systolic blood pressure (SBP) change triggered by the four different laryngoscopes. The intubation time, the number of intubation attempts, need for stylet or additional manipulation, glottic view and traumatic complications caused by intubation procedure were recorded as secondary outcomes. HR values significantly increased with the completion of laryngoscopy and intubation at T2 for the CL, MC and CM groups. Lesser fluctuation in HR and SBP was observed in the MG group. Intubation time was significantly shorter in the MG group (p<0.001). There was no statistically significant difference between the groups regarding the number of intubation attempts, need for stylette and glottic view. Fewer patients in the MG and CM groups experienced a moderate and severe sore throat than in the other two groups. Shorter intubation time and lesser sore throat incidence were observed in the MG group. MG offers less haemodynamic stimulation than CL, MC, and CM. Our findings showed that tracheal intubation with MG is advantageous in preventing cardiovascular stress responses with short intubation time and less sore throat incidence.

30 July 2020 in The Laryngoscope
Verified
Journal Article
Closed access
PDF file
DADemet Altun
Demet Altun
HKHakan Kara
Hakan Kara
EBErol Bozbora
Erol Bozbora
AAAchmet Ali
Achmet Ali
TDTuğçe Dinç
Tuğçe Dinç
EÇEmre Çamci
Emre Çamci

2 January 2017 in Turkish Journal of Anesthesia and Reanimation
Verified
Journal Article
Closed access
DADemet Altun
Demet Altun
MSMukadder Orhan Sungur
Mukadder Orhan Sungur
AAAchmet Ali
Achmet Ali
EBEmre Sertac Bingul
Emre Sertac Bingul
TSTulay Ozkan Seyhan
Tulay Ozkan Seyhan
ECEmre Camci
Emre Camci
The aim of this feasibility study was to investigate the first attempt success of ultrasonography (USG) in paediatric patients in predicting an appropriate cuffed endotracheal tube (ETT) size. Fifty children who were 1-10 years of age and who received general anaesthesia with endotracheal intubation for adenoidectomy or adenotonsillectomy were enrolled in the study. In all participants, the transverse diameter of the subglottic airway was measured with USG at the cricoid level without ventilation. The outer diameter (OD) of the maximum allowable ETT was chosen according to the measured subglottic airway diameter. In the presence of resistance to passage of the tube into the trachea or in the absence of an audible leak at airway pressure of >25 cm H2O, the ETT was replaced with a tube whose internal diameter (ID) was 0.5 mm smaller. If a leak was audible at airway pressures of 25 cm H2O or if a peak airway pressure of >25 cm H2O was observed during ventilation, the tube was changed to a tube one size larger. The OD of the best-fit ETT was converted to the ID. The best-fit ID, the requirement for ETT replacement, the duration of airway diameter measurement by USG and the peak airway pressure were recorded. The success rate of the first attempt with USG was 86%; the ETT was replaced in five patients with a tube one size larger and in two patients with a tube one size smaller. Our findings show the subglottic diameter measured by USG to be a reliable predictor in estimating the appropriate paediatric ETT size.

4 October 2019 in Pediatric Anesthesia
Verified
Journal Article
Closed access
PDF file
MSMukadder Orhan Sungur
Mukadder Orhan Sungur
DADemet Altun
Demet Altun
TÖTülay Özkan‐Seyhan
Tülay Özkan‐Seyhan
EAElif Aygün
Elif Aygün
KKKemalettin Koltka
Kemalettin Koltka
EÇEmre Çamcı
Emre Çamcı