Giada S. Romitti

Giada S. Romitti

Auto-generated profile, based on publicly available information

Giada S. Romitti

Computational Multiscale Simulation Laboratory (CoMMLab), Department of Computer Science and Department of Electronic Engineering, Universitat de València, Burjassot, Spain

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2025 in Medical Image Analysis
Verified
Journal Article
Open access
GRGiada S. Romitti
Giada S. Romitti
ALAlejandro Liberos
Alejandro Liberos
MTMaría Termenón-Rivas
María Termenón-Rivas
JAJavier Barrios-Álvarez de Arcaya
Javier Barrios-Álvarez de Arcaya
DADolors Serra Almor
Dolors Serra Almor
MRMiguel Rodrigo
Miguel Rodrigo
In silico models offer a promising advancement for studying cardiac arrhythmias and their clinical implications. However, existing detailed mathematical models often suffer from prolonged computational time compared to diagnostic needs. This study introduces a Cellular Automaton (CA) model tailored to replicate atrial electrophysiology in different stages of Atrial Fibrillation (AF), including persistent AF (PsAF). The CA, using a finite set of states, has been trained using biophysical simulations on a reduced domain for a large set of pacing conditions. Fine-tuning included tissue heterogeneity and anisotropic propagation through pacing simulations. Characterized by Action Potential Duration (APD), Diastolic Interval (DI) and Conduction Velocity (CV) for varying levels of electrical remodeling, the biophysical simulations introduced restitution curves or surfaces into the CA. Validation involved a comprehensive comparison with realistic 2D and 3D atrial models, evaluating healthy and pro-arrhythmic behaviors. Comparisons between CA and biophysical solver revealed striking proximity, with a Cycle Length difference of <10 ms in self-sustained re-entry and a 4.66±0.57 ms difference in depolarization times across the complete atrial geometry. Notably, the CA model exhibited a 80% accuracy, 96% specificity and 45% sensitivity in predicting AF inducibility under different pacing sites and substrate conditions. Additionally, the CA allowed for a 64-fold decrease in computing time compared to the biophysical solver. CA emerges as an efficient and valid model for simulation of atrial electrophysiology across different stages of AF, with potential as a general screening tool for rapid tests. While biophysical tests are recommended for investigating specific mechanisms, CA proves valuable in clinical applications for personalized therapy planning through digital twin simulations.

21 November 2025 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JAJavier Barrios-Álvarez de Arcaya
Javier Barrios-Álvarez de Arcaya
MTMaría Termenón-Rivas
María Termenón-Rivas
GRGiada S. Romitti
Giada S. Romitti
ALAlejandro Liberos
Alejandro Liberos
MRMiguel Rodrigo
Miguel Rodrigo

1 May 2026 in JRSM Cardiovascular Disease
Verified
Journal Article
Closed access
GRGiada S. Romitti
Giada S. Romitti
MTMaría Termenón-Rivas
María Termenón-Rivas
ALAlejandro Liberos
Alejandro Liberos
MRMiguel Rodrigo
Miguel Rodrigo
Atrial fibrillation (AF) prevalence has increased markedly over the past two decades, underscoring the need for personalized approaches to diagnosis, risk stratification, and therapy. Computational modeling provides a framework to integrate patient-specific anatomy and electrophysiology, offering mechanistic insights into arrhythmia susceptibility. We analyzed a virtual population of 160 bi-atrial models to investigate how structural and electrophysiological markers contribute to AF vulnerability and patterns. Each virtual patient incorporated geometries with varying enlargement, structural (conduction velocity, CV), and electrical (action potential duration, APD) remodeling. Virtual patients were characterized through anatomical markers, defined as inter-landmark distances, and electrophysiological markers, such as total activation time. AF vulnerability was tested by programmed stimulation from multiple atrial sites in 800 simulations. Lower CV and APD increased arrhythmic incidence, consistent with prior work. Larger atrial lateral extent and longer Bachmann's bundle length raised AF initiation likelihood by ∼20% ( p < 0.05), while total activation time did not distinguish inducible from non-inducible anatomies ( p > 0.05). Anatomical features, including superior-to-inferior vena cava distance, distinguished organized from disorganized patterns, while electrophysiological biomarkers alone did not. Combined high anatomical and electrophysiological marker values were linked to greater inducibility during AF progression (+20%). These findings provide mechanistic evidence for the role of atrial biomarkers in AF initiation and maintenance, highlighting the value of virtual populations in capturing inter-patient variability. By linking structural and electrophysiological characteristics to arrhythmic risk, this approach supports improved patient stratification and the design of individualized therapeutic strategies for AF.

29 August 2026 in Computers in Biology and Medicine
Verified
Journal Article
Open access
DLDuna de Luis-Moura
Duna de Luis-Moura
CCChiara Celotto
Chiara Celotto
SGSaman Golmaryami
Saman Golmaryami
MTMaría Termenón-Rivas
María Termenón-Rivas
GRGiada S. Romitti
Giada S. Romitti
MRMiguel Rodrigo
Miguel Rodrigo