Shamreen Iram

Shamreen Iram

Auto-generated profile, based on publicly available information

Shamreen Iram

Department of Physics, Case Western Reserve University, Cleveland, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in Nature Physics
Verified
Journal Article
Closed access
PDF file
SIShamreen Iram
Shamreen Iram
EDEmily Dolson
Emily Dolson
JCJoshua Chiel
Joshua Chiel
JPJulia Pelesko
Julia Pelesko
NKNikhil Krishnan
Nikhil Krishnan
MHMichael Hinczewski
Michael Hinczewski

12 October 2021 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
RARan An
Ran An
YMYuncheng Man
Yuncheng Man
SIShamreen Iram
Shamreen Iram
EKErdem Kucukal
Erdem Kucukal
MHMuhammad Noman Hasan
Muhammad Noman Hasan
Umut Atakan GurkanUmut Atakan Gurkan
Umut Atakan Gurkan
Anemia affects over 25% of the world's population with the heaviest burden borne by women and children. Genetic hemoglobin (Hb) variants, such as sickle cell disease, are among the major causes of anemia. Anemia and Hb variant are pathologically interrelated and have an overlapping geographical distribution. We present the first point-of-care (POC) platform to perform both anemia detection and Hb variant identification, using a single paper-based electrophoresis test. Feasibility of this new integrated diagnostic approach is demonstrated via testing individuals with anemia and/or sickle cell disease. Hemoglobin level determination is performed by an artificial neural network (ANN) based machine learning algorithm, which achieves a mean absolute error of 0.55 g dL−1 and a bias of −0.10 g dL−1 against the gold standard (95% limits of agreement: 1.5 g dL−1) from Bland–Altman analysis on the test set. Resultant anemia detection is achieved with 100% sensitivity and 92.3% specificity. With the same tests, subjects with sickle cell disease were identified with 100% sensitivity and specificity. Overall, the presented platform enabled, for the first time, integrated anemia detection and hemoglobin variant identification using a single point-of-care test.

29 November 2021 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
NPNiksa Praljak
Niksa Praljak
SIShamreen Iram
Shamreen Iram
UGUtku Goreke
Utku Goreke
GSGundeep Singh
Gundeep Singh
AHAilis Hill
Ailis Hill
MHMichael Hinczewski
Michael Hinczewski
Sickle cell disease, a genetic disorder affecting a sizeable global demographic, manifests in sickle red blood cells (sRBCs) with altered shape and biomechanics. sRBCs show heightened adhesive interactions with inflamed endothelium, triggering painful vascular occlusion events. Numerous studies employ microfluidic-assay-based monitoring tools to quantify characteristics of adhered sRBCs from high resolution channel images. The current image analysis workflow relies on detailed morphological characterization and cell counting by a specially trained worker. This is time and labor intensive, and prone to user bias artifacts. Here we establish a morphology based classification scheme to identify two naturally arising sRBC subpopulations—deformable and non-deformable sRBCs—utilizing novel visual markers that link to underlying cell biomechanical properties and hold promise for clinically relevant insights. We then set up a standardized, reproducible, and fully automated image analysis workflow designed to carry out this classification. This relies on a two part deep neural network architecture that works in tandem for segmentation of channel images and classification of adhered cells into subtypes. Network training utilized an extensive data set of images generated by the SCD BioChip, a microfluidic assay which injects clinical whole blood samples into protein-functionalized microchannels, mimicking physiological conditions in the microvasculature. Here we carried out the assay with the sub-endothelial protein laminin. The machine learning approach segmented the resulting channel images with 99.1±0.3% mean IoU on the validation set across 5k-folds, classified detected sRBCs with 96.0±0.3% mean accuracy on the validation set across 5k-folds, and matched trained personnel in overall characterization of whole channel images withR2= 0.992, 0.987 and 0.834 for total, deformable and non-deformable sRBC counts respectively. Average analysis time per channel image was also improved by two orders of magnitude (∼ 2 minutes vs ∼ 2-3 hours) over manual characterization. Finally, the network results show an order of magnitude less variance in counts on repeat trials than humans. This kind of standardization is a prerequisite for the viability of any diagnostic technology, making our system suitable for affordable and high throughput disease monitoring.

3 October 2018 in Advanced Optical Materials
Verified
Journal Article
Closed access
PDF file
MEMohamed ElKabbash
Mohamed ElKabbash
SIShamreen Iram
Shamreen Iram
TLTheodore Letsou
Theodore Letsou
MHMichael Hinczewski
Michael Hinczewski
Giuseppe StrangiGiuseppe Strangi
Giuseppe Strangi

20 February 2019 in Optical Materials Express
Verified
Journal Article
Closed access
PDF file
TLTheodore Letsou
Theodore Letsou
MEMohamed ElKabbash
Mohamed ElKabbash
SIShamreen Iram
Shamreen Iram
MHMichael Hinczewski
Michael Hinczewski
Giuseppe StrangiGiuseppe Strangi
Giuseppe Strangi
Heating reflective metals is known to produce a wide range of colors due to oxidation of the metal surface. In fact, the most vibrant colors used in the pre-industrial era came from oxides, acetates and carbonates of metal ores and minerals. In this work, we show that heating low reflectivity metals, e.g., Ni and Ti, creates structural colors through perfect light absorption. We tune the absorption across the visible and NIR spectrum by changing the heating duration and, consequently, the oxide thickness. We demonstrate experimentally angle-insensitive perfect and near-perfect absorption in the visible and NIR regimes up to ±60∘. The absorption is insensitive to the incidence angle due to the relatively high refractive index of the formed oxides, which create iridescent free coloration. We demonstrate that the oxide layer thickness, with refractive index n, is <λ/4n due to non-trivial phase change at the oxide/metal interfaces, which makes these systems the simplest example of meta-surfaces based on thin films. The results show that oxidized metals can have applications beyond producing vibrant colors.

4 May 2023 in Nature Physics
Verified
Journal Article
Closed access
PDF file
SIShamreen Iram
Shamreen Iram
MHMichael Hinczewski
Michael Hinczewski