Jason Zalev

Jason Zalev

Auto-generated profile, based on publicly available information

Jason Zalev

Toronto Metropolitan University, Toronto, Ontario, Canada

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JZJason Zalev
Jason Zalev
LRLisa M. Richards
Lisa M. Richards
BCBryan A. Clingman
Bryan A. Clingman
JHJeff Harris
Jeff Harris
ECEdgar Cantu
Edgar Cantu
MKMichael Kolios
Michael Kolios
Over the past 25 years, a growing community of researchers, clinicians, and device manufacturers have been investigating and developing translational opto-acoustic (OA) imaging technologies with the aim of improving clinical care for several diseases.1 – 6 For breast cancer diagnosis, one promising technique is OA imaging combined with ultrasound (OA/US).7 – 20 Combining OA with ultrasound is advantageous because each modality provides information that is complementary to the other. Structural and functional information pertaining to total hemoglobin concentration (ctHb) and blood oxygen saturation (sO2) can be visualized with OA, while morphological and anatomical information can be obtained with ultrasound. In conventional ultrasound, which is commonly used to assess and characterize breast masses, there is large overlap between benign and malignant image features, which results in false-positive cases that must be confirmed with subsequent biopsy.21 – 23 However, OA can provide functional information about the metabolism of tumors by imaging blood and vascular structure, which may further differentiate benign from malignant masses and potentially lead to improved patient care.

9 November 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MFMuhannad N Fadhel
Muhannad N Fadhel
EHEno Hysi
Eno Hysi
JZJason Zalev
Jason Zalev
MKMichael Kolios
Michael Kolios
A class of cancer therapeutic drugs targeting blood vessels, known as vascular disrupting agents (VDAs), induces intertumoral hemorrhage.1 The drugs are activated at the location of the tumor to disrupt endothelial and/or intravascular cells (e.g., red blood cells), which results in hemoglobin leakage into the surrounding tissues.1 – 3 The outcome is vessel disruption followed by tumor cell death and extensive hemorrhagic necrosis within hours of treatment delivery.4,5

4 March 2013
Verified
Conference Paper
Closed access
PDF file
JZJason Zalev
Jason Zalev
BCBryan Clingman
Bryan Clingman
RSRemie J Smith
Remie J Smith
DHDonald G Herzog
Donald G Herzog
TMThomas A Miller
Thomas A Miller
POPamela M Otto
Pamela M Otto
We report on findings from the clinical feasibility study of the ImagioTM. Breast Imaging System, which acquires two-dimensional opto-acoustic (OA) images co-registered with conventional ultrasound using a specialized duplex hand-held probe. Dual-wavelength opto-acoustic technology is used to generate parametric maps based upon total hemoglobin and its oxygen saturation in breast tissues. This may provide functional diagnostic information pertaining to tumor metabolism and microvasculature, which is complementary to morphological information obtained with conventional gray-scale ultrasound. We present co-registered opto-acoustic and ultrasonic images of malignant and benign tumors from a recent clinical feasibility study. The clinical results illustrate that the technology may have the capability to improve the efficacy of breast tumor diagnosis. In doing so, it may have the potential to reduce biopsies and to characterize cancers that were not seen well with conventional gray-scale ultrasound alone.

10 October 2018 in IEEE Signal Processing Letters
Verified
Journal Article
Closed access
JZJason Zalev
Jason Zalev
MKMichael Kolios
Michael Kolios
In certain imaging systems, acquired raw data is pre-processed with a filtering stage before being processed with an image reconstruction stage. During these sequential stages, distortions may arise if valid signal cannot adequately be distinguished from interference. To avoid these distortions, a mixed-domain proximal operator is mathematically formulated, which permits interference to be separated from data concurrently during a combined processing stage. The technique is demonstrated with an application involving opto-acoustic imaging. Reconstruction is performed with an accelerated proximal gradient method. Total-variation minimization is used to promote smoothness in the image domain. In the data domain, interference is modelled as a low-rank matrix, which corresponds to a few time dependent interference components being coupled to each channel by determined amounts. Results are presented that demonstrate the ability to separate interference on a digital phantom used to simulate opto-acoustic signals.

17 November 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JZJason Zalev
Jason Zalev
MKMichael Kolios
Michael Kolios
Simulation involves predicting responses of a physical system. In this article, we simulate opto-acoustic signals generated in a three-dimensional volume due to absorption of an optical pulse. A separable computational model is developed, which splits processing into two steps, permitting an order-of-magnitude improvement in computational efficiency over a non-separable model. The simulated signals represent acoustic waves, measured by a probe with a linear transducer array, in a rotated and translated coordinate frame. Light is delivered by an optical source that moves with the probe’s frame. A spatiotemporal impulse response for rectangular-element transducer geometry is derived using a Green’s function solution to the acoustic wave equation. The approach permits fast and accurate simulation for a probe with arbitrary trajectory, which is useful for modeling free-hand acquisitions. For a 3D volume of n3 voxels, computation is accelerated by a factor of n. This may potentially have application in opto-acoustic imaging, where clinicians visualize structural and functional features of biological tissue for assessment of cancer and other diseases.

14 September 2021 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Open access
JZJason Zalev
Jason Zalev
MKMichael Kolios
Michael Kolios
Opto-acoustic imaging systems detect acoustic waves produced by optical absorption to visualize molecular contrast in biological tissue. This permits non-invasive vascular assessment of benign and malignant tumors. In this article, we describe a framework to iteratively determine the motion of an opto-acoustic probe during a minimization-based image reconstruction process. The probe emits light and uses an ultrasonic transducer array to acquire data for cross-sectional slices of tissue. To improve visibility, our technique uses multiple 2D slices to perform 3D volumetric reconstruction. Our model includes wavelength-specific optical absorption, position-dependent illumination and a realistic transducer element geometry. We investigate this technique using simulated, experimentally collected, and clinically acquired data. By performing 3D image reconstruction on a digital phantom, we demonstrate estimation of elevational probe motion without external sensors. We compare images of a benign lesion from a clinical breast imaging study and observe significant artifact reduction and contrast-to-background ratio improvement using our technique. The approach has potential to improve opto-acoustic image visibility for assessment of breast cancer or other diseases.